Related papers: C-arm inverse geometry CT for 3D cardiac chamber m…
Focused transmits are the most commonly used transmit strategy for echocardiograms, but suffer from relatively low frame rates, and in 3D, even lower volume rates. Fast imaging based on unfocused transmits has disadvantages such as motion…
Cone-beam CT (CBCT) is widely used in clinical radiotherapy for image-guided treatment, improving setup accuracy, adaptive planning, and motion management. However, slow gantry rotation limits performance by introducing motion artifacts,…
Purpose: In conventional fluoroscopy-guided interventions, the 2D projective nature of X-ray imaging limits depth perception and leads to prolonged radiation exposure. Virtual fluoroscopy, combined with spatially tracked surgical…
Chest computed tomography (CT) imaging adds valuable insight in the diagnosis and management of pulmonary infectious diseases, like tuberculosis (TB). However, due to the cost and resource limitations, only X-ray images may be available for…
To shorten the door-to-puncture time for better treating patients with acute ischemic stroke, it is highly desired to obtain quantitative cerebral perfusion images using C-arm cone-beam computed tomography (CBCT) equipped in the…
The efficient construction of anatomical models is one of the major challenges of patient-specific in-silico models of the human heart. Current methods frequently rely on linear statistical models, allowing no advanced topological changes,…
Accurate 3D+t whole-heart mesh reconstruction from cine MRI is a clinically crucial yet technically challenging task. The difficulty of this task arises from two coupled factors: inherently sparse sampling of 3D cardiac anatomy by 2D image…
X-ray computed tomography is a powerful tool for volumetric imaging, where three-dimensional (3D) images are generated from a large number of individual X-ray projection images. Collecting the required number of low noise projection images…
In this paper we consider 3D axis-symmetric (AS) object reconstruction from single cone-beam x-ray projection data. Traditional x-ray CT fails to capture fleeting state of material due to the long time for data acquisition at all angles.…
Accurate analysis of cardiac motion is crucial for evaluating cardiac function. While dynamic cardiac magnetic resonance imaging (CMR) can capture detailed tissue motion throughout the cardiac cycle, the fine-grained 4D cardiac motion…
Myocardial motion tracking stands as an essential clinical tool in the prevention and detection of cardiovascular diseases (CVDs), the foremost cause of death globally. However, current techniques suffer from incomplete and inaccurate…
Cardiac digital twins (CDTs) provide personalized in-silico cardiac representations and hold great potential for precision medicine in cardiology. However, whole-heart CDT models that simulate the full organ-scale electromechanics of all…
Joint 2D cardiac segmentation and 3D volume reconstruction are fundamental to building statistical cardiac anatomy models and understanding functional mechanisms from motion patterns. However, due to the low through-plane resolution of cine…
Cine cardiac MRI is routinely acquired for the assessment of cardiac health, but the imaging process is slow and typically requires several breath-holds to acquire sufficient k-space profiles to ensure good image quality. Several…
Cardiac segmentation of atriums, ventricles, and myocardium in computed tomography (CT) images is an important first-line task for presymptomatic cardiovascular disease diagnosis. In several recent studies, deep learning models have shown…
Accurate 3D models of the human heart require not only correct outer surfaces but also realistic inner structures, such as the ventricles, atria, and myocardial layers. Approaches relying on implicit surfaces, such as signed distance…
We present 3DeepCT, a deep neural network for computed tomography, which performs 3D reconstruction of scattering volumes from multi-view images. Our architecture is dictated by the stationary nature of atmospheric cloud fields. The task of…
Deformable registration of two-dimensional/three-dimensional (2D/3D) images of abdominal organs is a complicated task because the abdominal organs deform significantly and their contours are not detected in two-dimensional X-ray images. We…
Based on a 3D pre-treatment magnetic resonance (MR) scan, we developed DREME-MR to jointly reconstruct the reference patient anatomy and a data-driven, patient-specific cardiorespiratory motion model. Via a motion encoder simultaneously…
Recent advances in telecommunications have enabled surgeons to operate remotely on patients with the use of robotics. The investigation and testing of remote surgery using a robotic arm is presented. The robotic arm is designed to have four…