English
Related papers

Related papers: Control of quality factor of atomic force microsco…

200 papers

The fundamental sensitivity limit of atomic force microscopy is strongly correlated to the thermal noise of the cantilever oscillation. A method to suppress this unwanted noise is to reduce the bandwidth of the measurement, but this…

Reliable operation of frequency modulation mode atomic force microscopy (FM-AFM) depends on a clean resonance of an AFM cantilever. It is recognized that the spurious mechanical resonances which originate from various mechanical components…

Mesoscale and Nanoscale Physics · Physics 2024-03-12 Yoichi Miyahara , Harrisonn Griffin , Antoine Roy-Gobeil , Ron Belyansky , Hadallia Bergeron , José Bustamante , Peter Grutter

A common use for atomic force microscopy is to quantify local forces through tip-sample interactions between the probe tip and a sample surface. The accuracy of these measurements depends on the accuracy to which the cantilever spring…

Mesoscale and Nanoscale Physics · Physics 2021-12-08 Aaron Mascaro , Yoichi Miyahara , Omur E. Dagdeviren , Peter Grutter

Dynamic-mode atomic force microscopy (AFM) in liquid remains complicated due to the strong viscous damping of the cantilever resonance. Here we show that a high-quality resonance (Q>20) can be achieved in aqueous solution by attaching a…

Instrumentation and Detectors · Physics 2015-05-14 Sebastian Hoof , Nitya Nand Gosvami , Bart W. Hoogenboom

Magnetic force microscopy (MFM) is a well-established technique in scanning probe microscopy that allows for the imaging of magnetic samples with a spatial resolution of tens of nm and stray fields down to the mT range. The spatial…

Mesoscale and Nanoscale Physics · Physics 2024-11-13 Christopher Habenschaden , Sibylle Sievers , Alexander Klasen , Andrea Cerreta , Hans Werner Schumacher

High-frequency atomic force microscopy has enabled extraordinary new science through large bandwidth, high speed measurements of atomic and molecular structures. However, traditional optical detection schemes restrict the dimensions, and…

Mesoscale and Nanoscale Physics · Physics 2014-03-11 C. Doolin , P. H. Kim , B. D. Hauer , A. J. R MacDonald , J. P Davis

We demonstrate the coupling between the fundamental and second flexural mode of a microcantilever. A mechanical analogue of cavity-optomechanics is then employed, where the mechanical cavity is formed by the second vibrational mode of the…

Mesoscale and Nanoscale Physics · Physics 2011-10-14 W. J. Venstra , H. J. R. Westra , H. S. J. van der Zant

The use of atomic force microscopy on nanomechanical measurements requires accurate calibration of the cantilever's spring constant ($k_c$) and the optical lever sensitivity ($OLS$). The thermal method, based on the cantilever's thermal…

Applied Physics · Physics 2021-09-08 Jorge Rodriguez-Ramos , Felix Rico

An ongoing challenge in atomic force microscope (AFM) experiments is the quantitative measurement of cantilever motion. The vast majority of AFMs use the optical beam deflection (OBD) method to infer the deflection of the cantilever. The…

Mesoscale and Nanoscale Physics · Physics 2015-05-22 Aleks Labuda , Roger Proksch

In multifrequency atomic force microscopy higher eigenmodes are externally excited to enhance resolution and contrast while simultaneously increasing the number of experimental observables with the use of gentle forces. Here, the…

Mesoscale and Nanoscale Physics · Physics 2014-07-14 Sergio Santos , Victor Barcons

We describe a method for feedback-regulation of a microcantilever's response using optical radiation pressure. One laser measures the position of the cantilever and another laser applies a force that is a phase-shifted function of that…

Other Condensed Matter · Physics 2009-11-11 D. M. Weld , A. Kapitulnik

In this article, we present a deflection measurement setup for Atomic Force Microscopy (AFM). It is based on a quadrature phase differential interferometer: we measure the optical path difference between a laser beam reflecting above the…

Instrumentation and Detectors · Physics 2015-06-16 Pierdomenico Paolino , Felipe A. Aguilar Sandoval , Ludovic Bellon

Atomic force microscopy (AFM) is an analytical surface characterization tool which can reveal a sample's topography with high spatial resolution while simultaneously probing tip-sample interactions. Local measurement of chemical properties…

Applied Physics · Physics 2018-09-06 Omur E. Dagdeviren , Yoichi Miyahara , Aaron Mascaro , Peter Grutter

The Transient Fluctuation Theorem is used to calibrate an Atomic Force Microscope by measuring the fluctuations of the work performed by a time dependent force applied between a collo{\"i}dal probe and the surface. From this measure one can…

Mesoscale and Nanoscale Physics · Physics 2020-12-02 Samuel Albert , Aubin Archambault , Artyom Petrosyan , Caroline Crauste-Thibierge , Ludovic Bellon , Sergio Ciliberto

Mechanical properties of biological samples have been imaged with a \textit{Force Feedback Microscope}. Force, force gradient and dissipation are measured simultaneously and quantitatively, merely knowing the AFM cantilever spring constant.…

Biological Physics · Physics 2014-05-01 Luca Costa , Mario S Rodrigues , Emily Newman , Chloe Zubieta , Joel Chevrier , Fabio Comin

A method to precisely calibrate the oscillation amplitude in Dynamic Scanning Force Microscopy is described. It is experimentally shown that a typical electronics used to process the dynamic motion of the cantilever can be adjusted to…

Amplitude-modulation atomic force microscopy (AM-AFM) measures nanoscale surface structures by detecting changes in the cantilever oscillation amplitude, contributing to materials research. AM-AFM can non-destructively observe fragile…

Applied Physics · Physics 2025-06-18 Kenichi Umeda , Karen Kamoshita , Noriyuki Kodera

Atomic force microscopy (AFM) is a versatile nanoscale imaging technique. Since its spatiotemporal resolution is fundamentally limited by the minimum detectable force (MDF) arising from system noise, a deep understanding of MDF is essential…

Applied Physics · Physics 2026-01-16 Kenichi Umeda , Noriyuki Kodera

A high quality factor (Q-factor) piezoelectric lead zirconat titanate (PZT) actuated single crystal silicon cantilever was proposed in this paper for resonant based ultra-sensitive mass detection. Energy dissipation from intrinsic…

Other Computer Science · Computer Science 2008-12-18 Jian Lu , T. Ikehara , Yi Zhang , Takashi Mihara , Toshihiro Itoh , Ryutaro Maeda

The frequency-dependent amplitude and phase in piezoresponse force microscopy (PFM) measurements are shown to be a consequence of the Euler-Bernoulli (EB) dynamics of atomic force microscope (AFM) cantilever beams used to make the…

Mesoscale and Nanoscale Physics · Physics 2015-09-02 Roger Proksch
‹ Prev 1 2 3 10 Next ›