Related papers: Generating Synthetic Computed Tomography for Radio…

200 papers

Purpose: This study assessed the dosimetric accuracy of synthetic CT images generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy, using a deep learning approach. Material and Methods: We conducted a study…

Computed tomography (CT) is critical for various clinical applications, e.g., radiotherapy treatment planning and also PET attenuation correction. However, CT exposes radiation during acquisition, which may cause side effects to patients.…

Computer Vision and Pattern Recognition · Computer Science 2016-12-19 Dong Nie , Roger Trullo , Caroline Petitjean , Su Ruan , Dinggang Shen

Computer-aided tumor detection has shown great potential in enhancing the interpretation of over 80 million CT scans performed annually in the United States. However, challenges arise due to the rarity of CT scans with tumors, especially…

Image and Video Processing · Electrical Eng. & Systems 2024-09-11 Qi Chen , Yuxiang Lai , Xiaoxi Chen , Qixin Hu , Alan Yuille , Zongwei Zhou

Computed tomography (CT) is a widely used imaging modality for medical diagnosis and treatment. In electroencephalography (EEG), CT imaging is necessary for co-registering with magnetic resonance imaging (MRI) and for creating more accurate…

Medical Physics · Physics 2019-06-12 Andreas D. Lauritzen , Xenophon Papademetris , Sergei Turovets , John A. Onofrey

Pancreatic cancer with more than 60,000 new cases each year has less than 10 percent 5-year overall survival. Radiation therapy (RT) is an effective treatment for Locally advanced pancreatic cancer (LAPC). The current clinical RT workflow…

Medical Physics · Physics 2023-06-07 Hamed Hooshangnejad , Quan Chen , Xue Feng , Rui Zhang , Kai Ding

Deep learning techniques, particularly convolutional neural networks (CNNs), have gained traction for synthetic computed tomography (sCT) generation from Magnetic resonance imaging (MRI), Cone-beam computed tomography (CBCT) and PET. In…

Image and Video Processing · Electrical Eng. & Systems 2023-08-29 Satoshi Kondo , Satoshi Kasai , Kousuke Hirasawa

In many clinical settings, the use of both Computed Tomography (CT) and Magnetic Resonance (MRI) is necessary to pursue a thorough understanding of the patient's anatomy and to plan a suitable therapeutical strategy; this is often the case…

Image and Video Processing · Electrical Eng. & Systems 2024-07-16 Leonardo Crespi , Samuele Camnasio , Damiano Dei , Nicola Lambri , Pietro Mancosu , Marta Scorsetti , Daniele Loiacono

Recently, deep learning (DL)-based methods for the generation of synthetic computed tomography (sCT) have received significant research attention as an alternative to classical ones. We present here a systematic review of these methods by…

Medical Physics · Physics 2021-08-30 Maria Francesca Spadea , Matteo Maspero , Paolo Zaffino , Joao Seco

Background: In MR-guided proton therapy planning, aligning MR and CT images is key for MR-based CT synthesis, especially in mobile regions like the head-and-neck. Misalignments here can lead to less accurate synthetic CT (sCT) images,…

MRI provides superior soft tissue contrast without ionizing radiation; however, the absence of electron density information limits its direct use for dose calculation. As a result, current radiotherapy workflows rely on combined MRI and CT…

Computer Vision and Pattern Recognition · Computer Science 2026-02-06 Zolnamar Dorjsembe , Hung-Yi Chen , Furen Xiao , Hsing-Kuo Pao

Background: Cone-beam computed tomography (CBCT) scans, performed fractionally (e.g., daily or weekly), are widely utilized for patient alignment in the image-guided radiotherapy (IGRT) process, thereby making it a potential imaging…

Photon-counting computed tomography (PCCT) marks a significant advancement over conventional energy-integrating detector (EID) CT systems. This review highlights PCCT's superior spatial and contrast resolution, reduced radiation dose, and…

A key step in Adaptive Radiation Therapy (ART) workflows is the evaluation of the patient's anatomy at treatment time to ensure the accuracy of the delivery. To this end, Cone Beam Computerized Tomography (CBCT) is widely used being…

Image and Video Processing · Electrical Eng. & Systems 2025-02-10 Ricardo Coimbra Brioso , Leonardo Crespi , Andrea Seghetto , Damiano Dei , Nicola Lambri , Pietro Mancosu , Marta Scorsetti , Daniele Loiacono

Supervised synthetic CT generation from CBCT requires registered training pairs, yet perfect registration between separately acquired scans remains unattainable. This registration bias propagates into trained models and corrupts standard…

Computer Vision and Pattern Recognition · Computer Science 2026-02-03 Lukas Zimmermann , Michael Rauter , Maximilian Schmid , Dietmar Georg , Barbara Knäusl

Objective: Cone-beam computed tomography (CBCT) provides a low-dose imaging alternative to conventional CT, but suffers from noise, scatter, and artifacts that degrade image quality. Synthetic CT (sCT) aims to translate CBCT to high-quality…

Medical Physics · Physics 2025-09-23 Alzahra Altalib , Chunhui Li , Alessandro Perelli

Cone-beam computed tomography (CBCT) offers advantages over conventional fan-beam CT in that it requires a shorter time and less exposure to obtain images. CBCT has found a wide variety of applications in patient positioning for…

Computer Vision and Pattern Recognition · Computer Science 2020-07-01 S. Kida , S. Kaji , K. Nawa , T. Imae , T. Nakamoto , S. Ozaki , T. Ohta , Y. Nozawa , K. Nakagawa

Attenuation correction is an essential requirement of positron emission tomography (PET) image reconstruction to allow for accurate quantification. However, attenuation correction is particularly challenging for PET-MRI as neither PET nor…

Positron Emission Tomography (PET) imaging requires accurate attenuation correction (AC) to account for photon loss due to tissue density variations. In PET/MR systems, computed tomography (CT), which offers a straightforward estimation of…

Image and Video Processing · Electrical Eng. & Systems 2025-04-11 Weijie Chen , James Wang , Alan McMillan

MR-only radiotherapy treatment planning requires accurate MR-to-CT synthesis. Current deep learning methods for MR-to-CT synthesis depend on pairwise aligned MR and CT training images of the same patient. However, misalignment between…

Computer Vision and Pattern Recognition · Computer Science 2017-08-04 Jelmer M. Wolterink , Anna M. Dinkla , Mark H. F. Savenije , Peter R. Seevinck , Cornelis A. T. van den Berg , Ivana Isgum

Accurate MR-to-CT synthesis is a requirement for MR-only workflows in radiotherapy (RT) treatment planning. In recent years, deep learning-based approaches have shown impressive results in this field. However, to prevent downstream errors…

Image and Video Processing · Electrical Eng. & Systems 2019-11-13 Louis D. van Harten , Jelmer M. Wolterink , Joost J. C. Verhoeff , Ivana Išgum