English
Related papers

Related papers: Elliptical Halbach magnet and gradient modules for…

200 papers

Purpose: To design a low-cost, portable permanent magnet-based MRI system capable of obtaining in vivo MR images within a reasonable scan time. Methods: A discretized Halbach permanent magnet array with a clear bore diameter of 27 cm was…

Medical Physics · Physics 2020-05-07 T. O'Reilly , W. M. Teeuwisse , D. de Gans , K. Koolstra , A. G. Webb

In this paper we design and construct gradient coils for a Halbach permanent magnet array magnetic resonance (MR) scanner. The target field method, which is widely applied for the case of axial static magnetic fields, has been developed for…

Medical Physics · Physics 2020-04-22 Bart de Vos , Patrick Fuchs , Thomas O'Reilly , Andrew Webb , Rob Remis

Access to and availability of MRI scanners is typically limited by their cost, siting and infrastructure requirements. This precludes MRI diagnostics, the reference standard for neurological assessment, in patients who cannot be transported…

Halbach magnets are a source of homogeneous magnetic field in an enclosed volume while keeping stray fields at a minimum. Here, we present the design, construction, and characterization for a 10 cm inner diameter double Halbach ring…

Instrumentation and Detectors · Physics 2021-02-24 Arne Wickenbrock , Huijie Zheng , Georgios Chatzidrosos , Joseph Shaji Rebeirro , Tim Schneemann , Peter Bluemler

A design for a permanent magnet system is proposed that generates spatially homogeneous, constant magnetic field gradients, thus creating conditions suitable for MRI without gradient coils and amplifiers. This is achieved by superimposing a…

Instrumentation and Detectors · Physics 2015-10-12 Peter Blümler

We optimised the magnetic field homogeneity of two canonical designs for mobile microfluidic NMR applications: two parallel magnets with an air gap and a modified Halbach array. Along with the influence of the sample length, general design…

Applied Physics · Physics 2021-03-26 Yannick Klein , Leon Abelmann , Han Gardeniers

This paper presents the design and experimental characterization of a 1 T electromagnet tailored to meet the demands of a Magnetic Resonance Imaging (MRI) system conceived for spatial resolutions at the level of tens of microns. For high…

We present a design and the optimization of an irregular-shaped ring-pair magnet array that generates a 1D monotonic field pattern for 2D head imaging in a low-field portable MRI system. The magnet rings are discretized into fan-shaped ring…

Medical Physics · Physics 2019-01-08 Zhi Hua Ren , Jia Gong , Shao Ying Huang

Halbach spheres provide a theoretically elegant means of generating highly homogeneous magnetic fields, but practical implementation is hindered by challenging fabrication and restricted interior access. This study examines discrete…

Instrumentation and Detectors · Physics 2026-05-05 Ingo Rehberg , Peter Blümler

Homogeneous magnetic fields can be generated through the strategic arrangement of permanent magnets. The Halbach array serves as a prominent example of an effective design following this principle. However, it is a two-dimensional approach…

Materials Science · Physics 2025-06-02 Ingo Rehberg , Peter Blümler

In this paper we describe the results of a parameter survey of a 16 segmented Halbach cylinder in three dimensions in which the parameters internal radius, $r_{\mathrm{\scriptsize{in}}}$, external radius, $r_{\mathrm{\scriptsize{ex}}}$, and…

Instrumentation and Detectors · Physics 2014-09-16 R. Bjørk , C. R. H. Bahl , A. Smith , N. Pryds

We present a design for producing precisely adjustable and alternating single-axis magnetic fields based on nested Halbach dipole pairs consisting of permanent magnets only. Our design allows for three dimensional optical and mechanical…

Instrumentation and Detectors · Physics 2018-11-12 Oleg Tretiak , Peter Blümler , Lykourgos Bougas

Low-field MRI is increasingly considered accessible for imaging owing to its lower cost, simpler infrastructure requirements, and potential for mobile and point-of-care deployment. A central challenge is achieving clinically useful field…

Medical Physics · Physics 2026-04-28 Ivan Etoku Oiye , Ajay Sharma , Sairam Geethanath

Purpose: To demonstrate the feasibility of performing in vivo imaging and quantitative relaxation mapping of soft and hard tissues using a low-cost, portable MRI scanner, and to establish the methodological foundations for zero echo time…

A permanent magnet array (PMA) is a preferred source of magnetic field for body-part-dedicated low-field (<0.5 T) portable magnetic resonance imaging (MRI) because it has a small footprint, no power consumption, and no need for a cooling…

Medical Physics · Physics 2022-11-23 Ting-Ou Liang , Yan Hao Koh , Tie Qiu , Erping Li , Wenwei Yu , Shao Ying Huang

Portable low-cost MRI systems have the potential to enable point-of-care and timely MRI diagnosis, and to make this imaging modality available to routine scans and to underdeveloped areas. With simplicity, no maintenance, no power…

Medical Physics · Physics 2018-12-31 Shao Ying Huang , Zhi Hua Ren , Sergei Obruchkov , Jia Gong , Robin Dykstra , Wenwei Yu

A compact Halbach array magnet is used to measure the momentum of the secondary particles in EMPHATIC (Experiment to Measure the Production of Hadrons At a Test beam In Chicagoland). Hall probe data was taken for the central cylindrical…

High Energy Physics - Experiment · Physics 2025-01-07 Prachi Sharma

Accelerator magnets made from blocks of permanent magnets in a zero-clearance configuration are known as Halbach arrays. The objective of this work is the fusion of knowledge from different measurement sources (material and field) and…

Computational Engineering, Finance, and Science · Computer Science 2024-11-15 Luisa Fleig , Melvin Liebsch , Stephan Russenschuck , Sebastian Schöps

This review is a compilation of relevant concepts in designing Halbach multipoles for magnetic resonance applications. The main focus is on providing practical guidelines to plan, design and build such magnets. Therefore, analytical…

Instrumentation and Detectors · Physics 2023-11-20 Peter Blümler , Helmut Soltner

We report the design and development of a compact electron and positron spectrometer based on tapered Neodymium Iron Boron magnets. We show that the tapered design forms a gradient magnetic field component allowing energy dependent focusing…

Instrumentation and Detectors · Physics 2019-08-14 Ganesh Tiwari , Rotem Kupfer , Xuejing Jiao , Erhard Gaul , Bjorn Manuel Hegelich
‹ Prev 1 2 3 10 Next ›