English
Related papers

Related papers: Low-dose CT Denoising with Language-engaged Dual-s…

200 papers

Low-dose computed tomography (LDCT) reduces radiation exposure but often degrades image quality, potentially compromising diagnostic accuracy. Existing deep learning-based denoising methods focus primarily on pixel-level mappings,…

Image and Video Processing · Electrical Eng. & Systems 2025-07-09 Zhihao Chen , Tao Chen , Chenhui Wang , Qi Gao , Huidong Xie , Chuang Niu , Ge Wang , Hongming Shan

Low dose computed tomography (LDCT) is desirable for both diagnostic imaging and image guided interventions. Denoisers are openly used to improve the quality of LDCT. Deep learning (DL)-based denoisers have shown state-of-the-art…

Image and Video Processing · Electrical Eng. & Systems 2020-12-08 Ti Bai , Biling Wang , Dan Nguyen , Bao Wang , Bin Dong , Wenxiang Cong , Mannudeep K. Kalra , Steve Jiang

In clinical examinations and diagnoses, low-dose computed tomography (LDCT) is crucial for minimizing health risks compared with normal-dose computed tomography (NDCT). However, reducing the radiation dose compromises the signal-to-noise…

Image and Video Processing · Electrical Eng. & Systems 2024-07-02 Haoyu Zhao , Yuliang Gu , Zhou Zhao , Bo Du , Yongchao Xu , Rui Yu

Low-dose computed tomography (LDCT) lower potential risks linked to radiation exposure while relying on advanced denoising algorithms to maintain diagnostic quality in reconstructed images. The reigning paradigm in LDCT denoising is based…

Image and Video Processing · Electrical Eng. & Systems 2024-12-17 Şaban Öztürk , Oğuz Can Duran , Tolga Çukur

Low-dose CT (LDCT) significantly reduces the radiation dose received by patients, however, dose reduction introduces additional noise and artifacts. Currently, denoising methods based on convolutional neural networks (CNNs) face limitations…

Image and Video Processing · Electrical Eng. & Systems 2025-07-08 Linxuan Li , Wenjia Wei , Luyao Yang , Wenwen Zhang , Jiashu Dong , Yahua Liu , Hongshi Huang , Wei Zhao

Since 2016, deep learning (DL) has advanced tomographic imaging with remarkable successes, especially in low-dose computed tomography (LDCT) imaging. Despite being driven by big data, the LDCT denoising and pure end-to-end reconstruction…

Image and Video Processing · Electrical Eng. & Systems 2023-03-28 Wenjun Xia , Hongming Shan , Ge Wang , Yi Zhang

We propose a provably convergent method, called Efficient Learned Descent Algorithm (ELDA), for low-dose CT (LDCT) reconstruction. ELDA is a highly interpretable neural network architecture with learned parameters and meanwhile retains…

Image and Video Processing · Electrical Eng. & Systems 2021-04-28 Qingchao Zhang , Mehrdad Alvandipour , Wenjun Xia , Yi Zhang , Xiaojing Ye , Yunmei Chen

Low-dose computed tomography (LDCT) offers reduced X-ray radiation exposure but at the cost of compromised image quality, characterized by increased noise and artifacts. Recently, transformer models emerged as a promising avenue to enhance…

Image and Video Processing · Electrical Eng. & Systems 2023-10-20 Dayang Wang , Yongshun Xu , Shuo Han , Zhan Wu , Li Zhou , Bahareh Morovati , Hengyong Yu

To reduce radiation exposure and improve the diagnostic efficacy of low-dose computed tomography (LDCT), numerous deep learning-based denoising methods have been developed to mitigate noise and artifacts. However, most of these approaches…

Image and Video Processing · Electrical Eng. & Systems 2025-08-12 Runze Wang , Zeli Chen , Zhiyun Song , Wei Fang , Jiajin Zhang , Danyang Tu , Yuxing Tang , Minfeng Xu , Xianghua Ye , Le Lu , Dakai Jin

Computed tomography (CT) has played a vital role in medical diagnosis, assessment, and therapy planning, etc. In clinical practice, concerns about the increase of X-ray radiation exposure attract more and more attention. To lower the X-ray…

Image and Video Processing · Electrical Eng. & Systems 2022-01-19 Zhicheng Zhang , Xiaokun Liang , Wei Zhao , Lei Xing

The resurgence of deep neural networks has created an alternative pathway for low-dose computed tomography denoising by learning a nonlinear transformation function between low-dose CT (LDCT) and normal-dose CT (NDCT) image pairs. However,…

Image and Video Processing · Electrical Eng. & Systems 2022-11-04 Sutanu Bera , Prabir Kumar Biswas

Despite the indispensable role of X-ray computed tomography (CT) in diagnostic medicine field, the associated ionizing radiation is still a major concern considering that it may cause genetic and cancerous diseases. Decreasing the exposure…

Image and Video Processing · Electrical Eng. & Systems 2021-06-09 Ti Bai , Dan Nguyen , Biling Wang , Steve Jiang

Low-dose CT denoising is a challenging task that has been studied by many researchers. Some studies have used deep neural networks to improve the quality of low-dose CT images and achieved fruitful results. In this paper, we propose a deep…

Image and Video Processing · Electrical Eng. & Systems 2019-02-28 Maryam Gholizadeh-Ansari , Javad Alirezaie , Paul Babyn

Low-dose Computed Tomography (LDCT) reconstruction is an important task in medical image analysis. Recent years have seen many deep learning based methods, proved to be effective in this area. However, these methods mostly follow a…

Image and Video Processing · Electrical Eng. & Systems 2023-02-08 Runyi Li

Low dose computed tomography is a mainstream for clinical applications. How-ever, compared to normal dose CT, in the low dose CT (LDCT) images, there are stronger noise and more artifacts which are obstacles for practical applications. In…

Image and Video Processing · Electrical Eng. & Systems 2021-06-10 Dayang Wang , Zhan Wu , Hengyong Yu

With the development of deep learning, medical image processing has been widely used to assist clinical research. This paper focuses on the denoising problem of low-dose computed tomography using deep learning. Although low-dose computed…

Image and Video Processing · Electrical Eng. & Systems 2026-05-19 Zhilin Guan , Wei Zhang

Low-dose computed tomography (CT) represents a significant improvement in patient safety through lower radiation doses, but increased noise, blur, and contrast loss can diminish diagnostic quality. Therefore, consistency and robustness in…

Computer Vision and Pattern Recognition · Computer Science 2025-11-11 Kagan Celik , Mehmet Ozan Unal , Metin Ertas , Isa Yildirim

Low-dose computed tomography (LDCT) aims to minimize the radiation exposure to patients while maintaining diagnostic image quality. However, traditional CT reconstruction algorithms often struggle with the ill-posed nature of the problem,…

Image and Video Processing · Electrical Eng. & Systems 2024-10-17 Daisy Chen

Recently, Self-supervised learning methods able to perform image denoising without ground truth labels have been proposed. These methods create low-quality images by adding random or Gaussian noise to images and then train a model for…

Image and Video Processing · Electrical Eng. & Systems 2021-04-07 Dongkyu Won , Euijin Jung , Sion An , Philip Chikontwe , Sang Hyun Park

Recently, deep learning(DL) methods have been proposed for the low-dose computed tomography(LdCT) enhancement, and obtain good trade-off between computational efficiency and image quality. Most of them need large number of pre-collected…

Computer Vision and Pattern Recognition · Computer Science 2018-08-09 Mingrui Geng , Yun Deng , Qian Zhao , Qi Xie , Dong Zeng , Dong Zeng , Wangmeng Zuo , Deyu Meng
‹ Prev 1 2 3 10 Next ›