Related papers: Pulse shape discrimination in an organic scintilla…
An essential metric for the quality of a particle-identification experiment is its statistical power to discriminate between signal and background. Pulse shape discrimination (PSD) is a basic method for this purpose in many nuclear,…
We demonstrate the use of a convolutional neural network to perform neutron-gamma pulse shape discrimination, where the only inputs to the network are the raw digitised SiPM signals from a dual scintillator detector element made of…
(Gd,La)$_2$Si$_2$O$_7$:Ce (La-GPS:Ce) is a new scintillator material with high light output, high energy resolution, and fast decay time. Moreover, the scintillator has a good light output even at high temperature (up to 150$^\circ$C) and…
Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and…
In particle physics experiments, pulse shape discrimination (PSD) is a powerful tool for eliminating the major background from signals. However, the analysis methods have been a bottleneck to improving PSD performance. In this study, two…
A new type of neutron detector, named Stack Structure Solid organic Scintillator (S$^4$), consisting of multi-layer plastic scintillators with capability to suppress low-energy $\gamma$ rays under high-counting rate has been constructed and…
This paper, presents a simple method for accurate calibration of organic scintillation detectors. The method is based on the fact that differentiating the response function leads to accurate estimation of the Compton edge. The…
The use of programmable hardware devices is imperative for digital based pulse shape discrimination (PSD) to differentiate between various types of radiation. This work reports the development of a PSD algorithm based on tail area and total…
With the development of high-speed readout electronics, the digital pulse shape discrimination (PSD) methods have attracted the attention of more researchers, especially in the field of high energy physics and neutron detection. How to…
A novel algorithm for the discrimination of neutron and {\gamma}-ray with wavelet transform modulus maximum (WTMM) in an organic scintillation has been investigated. Voltage pulses arising from a BC501A organic liquid scintillation detector…
A comparative study of the neutron-$\gamma$ Pulse Shape Discrimination (PSD) with seven organic scintillators is performed using an identical setup and digital electronics. The scintillators include plastics (EJ-299-33 and a plastic…
Various pulse shape discrimination methods have been used to solve the neutron-gamma discrimination problem. But most of them are limited to off-line calculation due to the computation amount and FPGA performance. In order to realize real…
A method that uses fuzzy clustering algorithms to achieve particle identification based on pulse shape analysis is presented. The fuzzy c-means clustering algorithm is used to compute mean (principal) pulse shapes induced by different…
In this work, we present results for discrimination of neutron and $\gamma$ events using a plastic scintillator detector with pulse shape discrimination capabilities. Machine learning (ML) algorithms are used to improve the discriminatory…
Pulse shape discrimination (PSD) is one of the most distinctive features of liquid scintillators. Since the introduction of the scintillation techniques in the field of particle detection, many studies have been carried out to characterize…
Pulse-shape discrimination (PSD) is usually achieved using the different fast and slow decay components of inorganic scintillators, such as BaF2, CsI:Tl, etc. However, LaBr3:Ce is considered to not possess different components at room…
Proportional scintillation counters (PSCs), both single- and dual-phase, can measure the scintillation (S1) and ionization (S2) channels from particle interactions within the detector volume. The signal obtained from these detectors depends…
A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with EJ-301 liquid scintillation detector. The module was operated by means of running programs developed in LabVIEW with the…
In this manuscript we report on the scintillation properties and pulse shape discrimination (PSD) performance of new organic glass scintillator. Two cylindrical samples with dimensions of 2x2 inches were tested. Additionally, this two…
There are recent interests with CsI(Tl) scintillating crystals for Dark Matter experiments. The key merit is the capability to differentiate nuclear recoil (nr) signatures from the background $\beta / \gamma$-events due to ambient…