Related papers: Limited-angle TOF-PET for intraoperative surgical …
Limited-angle computerized tomography stands for one of the most difficult challenges in imaging. Although it opens the way to faster data acquisition in industry and less dangerous scans in medicine, standard approaches, such as the…
Positron emission tomography (PET) is widely used in various clinical applications, including cancer diagnosis, heart disease and neuro disorders. The use of radioactive tracer in PET imaging raises concerns due to the risk of radiation…
The use of Time Of Flight (TOF) in Positron Emission Tomography (PET) is expected to reduce noise on images, thanks to the additional information. In clinical routine, a common reconstruction approach is the use of maximum likelihood…
As the medical usage of computed tomography (CT) continues to grow, the radiation dose should remain at a low level to reduce the health risks. Therefore, there is an increasing need for algorithms that can reconstruct high-quality images…
Computed Tomography is one of the efficient and vital modalities of non-destructive techniques (NDT). Various factors influence the CT reconstruction result, including limited projection data, detector electronics optimization, background…
Proton computed tomography (CT) is similar to x-ray CT but relies on protons rather than photons to form an image. In its most common operation mode, the measured quantity is the amount of energy that a proton has lost while traversing the…
Low dose computed tomography (LDCT) has attracted more and more attention in routine clinical diagnosis assessment, therapy planning, etc., which can reduce the dose of X-ray radiation to patients. However, the noise caused by low X-ray…
Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…
We introduce a dual-wavelength Fourier ptychographic topography (FPT) method that extends the lambda/2 height-range limit of single-wavelength FPT. By reconstructing complex fields at two illumination wavelengths and exploiting their phase…
To facilitate a prospective estimation of CT effective dose and risk minimization process, a prospective spatial dose estimation and the known anatomical structures are expected. To this end, a CT reconstruction method is required to…
In this paper, a new tool for Doppler tomography, Tomo-V (https://tomo-v.inasan.ru) that is developed based on the algebraic reconstruction technique (ART) has been presented. Previously, the ART method has not been widely used in…
Combining dual-energy computed tomography (DECT) with positron emission tomography (PET) offers many potential clinical applications but typically requires expensive hardware upgrades or increases radiation doses on PET/CT scanners due to…
In this study we address the feasibility and main properties of a positron emission tomograph (PET) based on RPCs. The concept, making use of the converter-plate principle, takes advantage of the intrinsic layered structure of RPCs and its…
Low performance pixels (LPP) in Computed Tomography (CT) detectors would lead to ring and streak artifacts in the reconstructed images, making them clinically unusable. In recent years, several solutions have been proposed to correct LPP…
Low-count reconstruction remains a challenge for Positron Emission Tomography (PET) even with the recent progress in time-of-flight (TOF) resolution. In this context, the bias between the acquired histogram, consisting of low values or…
CT image-guided thermal ablation is widely used for lung cancer treatment; however, follow-up data indicate that physicians' subjective assessments of intraoperative images often overestimate the ablation effect, potentially leading to…
An InAlN/GaN HEMT device was studied using extensive temperature dependent DC IV measurements and CV measurements. Barrier traps in the InAlN layer were characterized using transient analysis. Forward gate current was modelled using…
We present a benchmark pilot study in which high-resolution Full-Field Optical Coherence Tomography (FF-OCT) is used to image human breast tissue and is evaluated to assess its ability to aid the pathologist's management of intra-operative…
Intensity-modulated proton therapy (IMPT) employs proton radiation rather than conventional X-rays to treat cancerous tumors. This approach offers significant advantages by minimizing the radiation exposure of surrounding healthy tissue,…
PET/CT imaging is the gold standard for tumor detection, offering high accuracy in identifying local and metastatic lesions. Radiologists often begin assessment with rotational Multi-Angle Maximum Intensity Projections (MIPs) from PET,…