A cryogenic detector system based on two 3.3 kg high-purity CsI crystals was developed and characterized at approximately 95 K. Each wedge-shaped crystal was coupled to dual-ended 3-inch photomultiplier tubes (PMTs) for scintillation…

Instrumentation and Detectors · Physics 2025-09-23 Chen'guang Su , Lingquan Kong , Qian Liu , Shi Chen , Wenqian Huang , Kimiya Moharrami , Yangheng Zheng , Jin Li

This paper presents a world-leading scintillation light yield among inorganic crystals measured from a 0.5~kg pure-CsI detector operated at 77 Kelvin. Scintillation photons were detected by two 2-inch Hamamatsu SiPM arrays equipped with…

Instrumentation and Detectors · Physics 2024-04-17 L. Wang , G. d. Li , Z. Y. Yu , X. H. Liang , T. A. Wang , F. Liu , X. L. Sun , C. Guo , X. Zhang , L. Yu , Y. D. Chen

CryoCsI, the proposed prototype, is a cryogenic undoped CsI scintillating detector, which has a much lower energy threshold potentially down to 0.5 keV$_{nr}$ compared to the doped CsI. This enhanced sensitivity of CryoCsI allows for the…

Instrumentation and Detectors · Physics 2024-05-31 Keyu Ding

We have measured scintillation properties of pure CsI crystals used in the shower calorimeter built for a precise determination of the pi+ -> pi0 e+ nu decay rate at the Paul Scherrer Institute (PSI). All 240 individual crystals painted…

High Energy Physics - Experiment · Physics 2009-10-31 E. Frlez , Ch. Broennimann , B. Krause , D. Pocanic , D. Renker , S. Ritt , P. L. Slocum , I. Supek , H. P. Wirtz

We report on the scintillation characterization of a 1 cm^3 CsI(Tl) crystal coupled to a 6 x 6 mm^2 SiPM read out with a custom transimpedance amplifier at cryogenic temperatures. The crystal was prepared with optical-grade surfaces and…

Instrumentation and Detectors · Physics 2025-11-19 M. Mirzakhani , R. Mahapatra , M. Platt

A light yield of 20.4 $\pm$ 0.8 photoelectrons/keV was achieved with an undoped CsI crystal coupled directly to a photomultiplier tube at 77 Kelvin. This is by far the largest yield in the world achieved with CsI crystals. An energy…

Instrumentation and Detectors · Physics 2016-10-06 Jing Liu , Masaki Yamashita , Arun Kumar Soma

Scintillation at cryogenic temperatures can give rise to detectors with particle discrimination for rare-event searches such as dark matter detection. We present time-resolved scintillation studies of Caesium Iodide (CsI) under excitation…

Instrumentation and Detectors · Physics 2018-06-18 Michael Clark , Patrick Nadeau , Shane Hills , Christophe Dujardin , Philippe Di Stefano

Total Body PET (TBPET) scanners have recently demonstrated the ability to significantly reduce both acquisition time and the administered radioactive dose, thanks to their increased sensitivity. However, their widespread adoption is limited…

Instrumentation and Detectors · Physics 2025-06-25 S. R. Soleti , A. Castillo , J. I. Collar , M. del Barrio-Torregrosa , C. Echeverria , M. Seemann , D. Zerzion , J. J. Gómez Cadenas

Cryogenic detectors have a long history of success in the field of rare event searches. In particular scintillating calorimeters are very suitable detectors for this task since they provide particle discrimination: the simultaneous…

The light yield of a small undoped cesium iodide (CsI) crystal directly coupled with two silicon photomultipliers (SiPMs) at about 77~Kelvin was measured to be $43.0 \pm 1.1$~photoelectrons (PE) per keV electron-equivalent (keV$_\text{ee}$)…

Instrumentation and Detectors · Physics 2022-04-26 Keyu Ding , Jing Liu , Yongjin Yang , Dmitry Chernyak

Investigated in this work were sensitivities of a prototype detector for the detection of low-mass dark matter particles produced at the Spallation Neutron Source at the Oak Ridge National Laboratory in two years of data taking. The…

Instrumentation and Detectors · Physics 2020-06-23 Dmitry Chernyak , Daniel Pershey , Jing Liu , Keyu Ding , Nathan Saunders , Tupendra Oli

A photomultiplier setup for precise relative CsI(Tl) crystal light yield and uniformity measurements is described. It is used for wrapping material studies to optimize the uniformity and the yield of the light output of 36 cm long crystals.…

Instrumentation and Detectors · Physics 2015-06-26 J. Brose , G. Dahlinger , K. R. Schubert

The scintillation characteristics of 1 g undoped CsI crystal were studied by directly coupling two silicon photomultipliers(SiPMs) over a temperature range from room temperature to 86 K. The scintillation decay time and light output were…

Instrumentation and Detectors · Physics 2025-08-01 W. K. Kim , H. Y. Lee , K. W. Kim , Y. J. Ko , J. A. Jeon , H. J. Kim , H. S. Lee

There is a global trend to increase the light yield of CsI scintillators used in neutrino and dark matter detection by operating undoped crystals at cryogenic temperatures. However, high light yield alone is not sufficient to guarantee a…

Instrumentation and Detectors · Physics 2023-07-25 K. Ding , J. Liu , Y. Yang , K. Scholberg , D. M. Markoff

Total Body PET (TBPET) scanners have the potential to substantially reduce both acquisition time and administered radiation dose, owing to their high sensitivity. However, their widespread clinical adoption is hindered by the high cost of…

Previous studies showed that CsI(Na) crystals have significantly different waveforms between alpha and gamma scintillations. In this work, the light yield and PSD capability of CsI(Na) scintillators as a function of the temperature down to…

Instrumentation and Detectors · Physics 2017-01-19 Xuan Zhang , Xilei Sun , Junguang Lu , Pin Lv

The bright scintillation of pure CsI operated at liquid-nitrogen temperature makes of this material a promising dark matter and neutrino detector. We present the first measurement of its quenching factor for nuclear recoils. Our findings…

Instrumentation and Detectors · Physics 2021-07-21 C. M. Lewis , J. I. Collar

Detector efficiency determination is essential to correct the measured yields and extract reliable cross sections of particles emitted in nuclear reactions. We investigate the efficiencies for measuring the full energies of light charged…

Instrumentation and Detectors · Physics 2017-02-01 P. Morfouace , W. G. Lynch , M. B. Tsang

To study an alternative to BaF2, as the crystal choice for the Mu2e calorimeter, thirteen pure CsI crystals from Opto Materials and ISMA producers have been characterized by determining their light yield (LY) and longitudinal response…

Instrumentation and Detectors · Physics 2016-06-24 M. Angelucci , O. Atanova , S. Baccaro , A. Cemmi , M. Cordelli , R. Donghia , S. Giovannella , F. Happacher , S. Miscetti , I. Sarra , S. R. Soleti

Scintillation properties of pure CsI crystals used in the shower calorimeter being built for precise determination of the pi+ -> pi0 e+ nu decay rate are reported. Seventy-four individual crystals, polished and wrapped in Teflon foil, were…