English
Related papers

Related papers: Longevity Studies of CSC Prototypes Operating with…

200 papers

The long-term stability in terms of gain and energy resolution of a prototype triple Gas Electron Multiplier (GEM) detector has been investigated with high rate X-ray irradiation. Premixed Ar/CO2 (80:20) and (90:10) gases have been used for…

Instrumentation and Detectors · Physics 2021-07-05 S Chatterjee , S Roy , A Sen , S Chakraborty , S Das , S K Ghosh , S K Prasad , S Raha , S Biswas

Experimental conditions at the HERA-B experiment impose very strong requirements for gaseous detectors. The charged particle fluxes through the HERA-B tracking system, varying with the radial distance $R$ from the beam line, are about $2…

High Energy Physics - Experiment · Physics 2007-05-23 M. Danilov , Yu. Gilitsky , T. Kvaratschellia , L. Laptin , I. Tichomirov , M. Titov , Yu. Zaitsev

Experimental conditions at the HERA-B experiment impose very strong requirements for gaseous detectors. The charged particle fluxes through the HERA-B tracking system, varying with the radial distance R from the beam line, are about $2…

High Energy Physics - Experiment · Physics 2007-05-23 M. Danilov , Yu. Gilitsky , T. Kvaratschellia , L. Laptin , I. Tichomirov , M. Titov , Yu. Zaitsev

The Muon Detector of the HERA-B experiment at DESY is a gaseous detector that provides muon identification in a high-rate hadronic environment. We present our studies on the properties of several fast gases, Ar/CF4/CH4 (74:20:6), Ar/CF4/CH4…

High Energy Physics - Experiment · Physics 2009-09-25 M. Danilov , L. Laptin , I. Tichomirov , M. Titov , Yu. Zaitsev

The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF$_4$ based gas mixtures were used in two different…

The performance of a small prototype of a cylindrical drift chamber (CDC) used in the COMET Phase-I experiment was studied by using an electron beam. The prototype chamber was constructed with alternating all-stereo wire configuration and…

Instrumentation and Detectors · Physics 2021-09-07 C. Wu , T. S. Wong , Y. Kuno , M. Moritsu , Y. Nakazawa , A. Sato , H. Sakamoto , N. H. Tran , M. L. Wong , H. Yoshida , T. Yamane , J. Zhang

A study has been carried out to evaluate the performance stability of Gas Electron Multiplier (GEM) chamber prototypes in the laboratory using $^{55}$Fe radiation source with Argon and CO$_2$ gas mixture. This research focuses on the…

Instrumentation and Detectors · Physics 2026-04-10 S. Mandal , S. Gope , S. Das , S. Biswas

Recent results of an aging test performed at the CERN Gamma Irradiation Facility on a single--gap RPC prototype developed for the LHCb Muon System are presented. The results are based on an accumulated charge of about 0.45 C/cm$^2$,…

In this paper, we report on the design and operation of the LongBo time projection chamber in the Liquid Argon Purity Demonstrator cryostat. This chamber features a 2 m long drift distance. We measure the electron drift lifetime in the…

Instrumentation and Detectors · Physics 2015-08-04 C. Bromberg , B. Carls , D. Edmunds , A. Hahn , W. Jaskierny , H. Jostlein , C. Kendziora , S. Lockwitz , B. Pahlka , S. Pordes , B. Rebel , D. Shooltz , M. Stancari , T. Tope , T. Yang

The preliminary results of an aging test performed at the CERN Gamma Irradiation Facility on a single--gap RPC prototype developed for the LHCb Muon System are presented. The results are based on an accumulated charge density of 0.42…

Resistive Plate Chambers detectors are extensively used in several domains of Physics. In High Energy Physics, they are typically operated in avalanche mode with a high-performance gas mixture based on Tetrafluoroethane (C2H2F4), a…

Instrumentation and Detectors · Physics 2025-10-08 D. Ahmadi , M. Tytgat

Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas…

We report on the successful operation of a double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) equipped with two dimensional projective anodes with dimensions 10$\times$10 cm$^2$, and with a maximum…

Instrumentation and Detectors · Physics 2015-06-18 C. Cantini , L. Epprecht , A. Gendotti , S. Horikawa , S. Murphy , G. Natterer , L. Periale , F. Resnati , A. Rubbia , F. Sergiampietri , T. Viant , S. Wu

Gated wires are widely used in Time Projection Chamber (TPC) to avoid ion back-flow (IBF) in the drift volume. The anode wires can provide stable gain at high voltage with a long lifetime. However, switching on and off the gated grid (GG)…

Instrumentation and Detectors · Physics 2019-07-24 Shuai Wang , Fuwang Shen , Xiao Zhao , Zhihang Zhu , Fangang Kong , Changyu Li , Qinghua Xu , Zhangbu Xu , Chi Yang , Chengguang Zhu

The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

The experimental EXCITOR setup for obtaining the intense electron beams of picosecond duration is presented in this work. Cathodes of tungsten, graphite, copper and samarium of the same shape were used in these experiments. The…

We observe 84 candidate young high-mass sources in the rare isotopologues C17O and C18O to investigate whether there is evidence for depletion (freeze-out) towards these objects. Observations of the J=2-1 transitions of C18O and C17O are…

Astrophysics · Physics 2009-11-13 H. S. Thomas , G. A. Fuller

The present paper is meant as an update of the presentation given in a previous Resistive Plate Chamber (RPC) workshop, aimed at finding an eco-friendly gas mixture for streamer operation of RPCs. Indeed the streamer working regime is still…

Instrumentation and Detectors · Physics 2019-09-04 A. Paoloni , A. Mengucci , M. Spinetti , M. Ventura , L. Votano

Resistive Plate Chambers (RPC) have shown stable operation at the Large Hadron Collider and satisfactory efficiency for the entire Run 1 (2010-2013) and Run 2 (2015-2018) with C$_{2}$H$_{2}$F$_{4}$-based gas mixtures and the addition of…

A novel idea to control ion back-flow in time projection chambers is to use a multi-layer extended gating grid to capture back-flowing ions at the expense of live time and electron transparency. In this initial study, I perform simulations…

Instrumentation and Detectors · Physics 2016-03-21 J. D. Mulligan
‹ Prev 1 2 3 10 Next ›