Related papers: Equivariant Multiscale Learned Invertible Reconstr…
Computed Tomography (CT) is pivotal in industrial quality control and medical diagnostics. Sparse-view CT, offering reduced ionizing radiation, faces challenges due to its under-sampled nature, leading to ill-posed reconstruction problems.…
Cone Beam Computed Tomography(CBCT) is a now known method to conduct CT imaging. Especially, The Low Dose CT imaging is one of possible options to protect organs of patients when conducting CT imaging. Therefore Low Dose CT imaging can be…
Image reconstruction from insufficient data is common in computed tomography (CT), e.g., image reconstruction from truncated data, limited-angle data and sparse-view data. Deep learning has achieved impressive results in this field.…
Cone-beam breast computed tomography (CT) provides true 3D breast images with isotropic resolution and high-contrast information, detecting calcifications as small as a few hundred microns and revealing subtle tissue differences. However,…
Computed Tomography (CT) reconstruction of objects with cylindrical symmetry can be performed with a single projection. When the measured rays are parallel, and the axis of symmetry is perpendicular to the optical axis, the data can be…
Sparse-view Computed Tomography (CT) is an emerging protocol designed to reduce X-ray dose radiation in medical imaging. Traditional Filtered Back Projection algorithm reconstructions suffer from severe artifacts due to sparse data. In…
Cone-beam computed tomography (CBCT) is an imaging modality widely used in head and neck diagnostics due to its accessibility and lower radiation dose. However, its relatively long acquisition times make it susceptible to patient motion,…
Accurate dose calculations in proton therapy rely on high-quality CT images. While planning CTs (pCTs) serve as a reference for dosimetric planning, Cone Beam CT (CBCT) is used throughout Adaptive Radiotherapy (ART) to generate sCTs for…
While model-based reconstruction methods have been successfully applied to flat-panel cone-beam CT (FP-CBCT) systems, typical implementations ignore both spatial correlations in the projection data as well as system blurs due to the…
Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy (IGRT). It provides real time visualization at low cost and dose. However, photon scattering and beam hindrance cause artifacts in CBCT. These include…
The recent application of Fourier Based Iterative Reconstruction Method (FIRM) has made it possible to achieve high-quality 2D images from a fan beam Computed Tomography (CT) scan with a limited number of projections in a fast manner. The…
Objective: To propose a CBCT dose optimization method using readily available measurement equipment in radiation oncology departments. Approach: A 0.6cc air kerma (Kair) calibrated Farmer chamber measured Kair at isocenter for five default…
Cone-beam CT (CBCT) is widely used in clinical radiotherapy for image-guided treatment, improving setup accuracy, adaptive planning, and motion management. However, slow gantry rotation limits performance by introducing motion artifacts,…
Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We…
Real-time cone-beam computed tomography (CBCT) provides instantaneous visualization of patient anatomy for image guidance, motion tracking, and online treatment adaptation in radiotherapy. While many real-time imaging and motion tracking…
Scatter can account for large errors in cone-beam CT (CBCT) due to its wide field of view, and its complicated nature makes its compensation difficult. Iterative polyenergetic reconstruction algorithms offer the potential to provide…
Image-generative artificial intelligence (AI) has garnered significant attention in recent years. In particular, the diffusion model, a core component of generative AI, produces high-quality images with rich diversity. In this study, we…
Obtaining accurate and reliable images from low-dose computed tomography (CT) is challenging. Regression convolutional neural network (CNN) models that are learned from training data are increasingly gaining attention in low-dose CT…
Cardiac magnetic resonance imaging (CMR) has been widely used in clinical practice for the medical diagnosis of cardiac diseases. However, the long acquisition time hinders its development in real-time applications. Here, we propose a novel…
Compressed sensing (CS) computed tomography has been proven to be important for several clinical applications, such as sparse-view computed tomography (CT), digital tomosynthesis and interior tomography. Traditional compressed sensing…