Related papers: Multimodal surface coils for low-field MR imaging
The recent introduction of portable, low-field MRI (LF-MRI) into the clinical setting has the potential to transform neuroimaging. However, LF-MRI is limited by lower resolution and signal-to-noise ratio, leading to incomplete…
Magnetic resonance imaging systems rely on signal detection via radiofrequency coil arrays which, ideally, need to provide both bendability and form-fitting stretchability to conform to the imaging volume. However, most commercial coils are…
Reducing the scanning time of very-low field (VLF) magnetic resonance imaging (MRI) scanners, commonly employed for stroke diagnosis, can enhance patient comfort and operational efficiency. The conventional parallel imaging (PI) technique…
Magnetic resonance imaging (MRI) is widely used for screening, diagnosis, image-guided therapy, and scientific research. A significant advantage of MRI over other imaging modalities such as computed tomography (CT) and nuclear imaging is…
Ongoing effort has been devoted to applying metamaterials to boost the imaging performance of magnetic resonance imaging owing to their unique capacity for electromagnetic field confinement and enhancement. However, there are still major…
Very-low-field MRIs are becoming increasingly popular due to their portability and adaptability to different environments. They are being successfully used for various clinical applications, leading to a paradigm shift in the way imaging…
This article presents a novel undersampled magnetic resonance imaging (MRI) technique that leverages the concept of Neural Radiance Field (NeRF). With radial undersampling, the corresponding imaging problem can be reformulated into an image…
This work investigates the effect of double intelligent reflecting surface (IRS) in improving the spectrum efficient of multi-user multiple-input multiple-output (MIMO) network operating in the millimeter wave (mmWave) band. Specifically,…
Here a minimum power dissipation coil transducer has been designed to allow in-flight noise characterization of a low-frequency magnetic measurement system. The coil was produced using PCB technology to provide mechanical stability and easy…
Reconfigurable intelligent surface (RIS)-aided cell-free (CF) massive multiple-input multiple-output (mMIMO) is a promising technology for further improving spectral efficiency (SE) with low cost and power consumption. However, conventional…
Magnetic Resonance Imaging (MRI) field-strength enhancement holds immense value for both clinical diagnostics and advanced research. However, existing methods typically focus on isolated enhancement tasks, such as specific 64mT-to-3T or…
Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) provides a higher signal-to-noise ratio and, thereby, higher spatial resolution. However, UHF MRI introduces challenges such as transmit radiofrequency (RF) field (B1+) inhomogeneities,…
Magnetoencephalography (MEG) conventionally operates within high-performance magnetic shields due to the extremely weak magnetic field signals from the measured objects and the narrow dynamic range of the magnetic sensors employed for…
'Coil design' is an inverse problem in which arrangements of wire are designed to generate a prescribed magnetic field when energized with electric current. The design of gradient and shim coils for magnetic resonance imaging (MRI) are…
Low-field magnetic resonance imaging (MRI) provides affordable access to diagnostic imaging but suffers from prolonged acquisition and limited image quality. Accelerated imaging can be achieved with k-space undersampling, while…
The need for affordable and appropriate medical technologies for developing countries continue to rise as challenges such as inadequate energy supply, limited technical expertise and poor infrastructure persists. Low-field MRI is a…
Three-dimensional reconstruction of cortical surfaces from MRI for morphometric analysis is fundamental for understanding brain structure. While high-field MRI (HF-MRI) is standard in research and clinical settings, its limited availability…
Magnetic resonance imaging (MRI) is the gold standard imaging modality for numerous diagnostic tasks, yet its usefulness is tempered due to its high cost and infrastructural requirements. Low-cost very-low-field portable scanners offer new…
Purpose: Despite decades of collective experience, radiofrequency coil optimization for MR has remained a largely empirical process, with clear insight into what might constitute truly task-optimal, as opposed to merely 'good,' coil…
Ultra-low-field (ULF, <0.1 T) magnetic resonance imaging (MRI) systems offer advantages in cost, portability, and accessibility, but their current utility is still limited by low signal-to-noise ratio (SNR). Deep learning (DL)-based…