The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. In this study, we utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high count rate…
The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36-pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low…
The effective bandwidth of an energy dispersive x-ray fluorescence spectroscopy system is limited by the timing of incident photons. When multiple photons strike the detector within the processing time of the detector photon pile-up occurs…
Using simultaneous observations in X-rays and optical, we have performed a homogeneous analysis of the cross-correlation behaviours of four X-ray binaries: SWIFT J1753.5-0127, GX 339-4, Sco X-1, and Cyg X-2. With high time-resolution…
The Resolve soft X-ray spectrometer is the high spectral resolution microcalorimeter spectrometer for the XRISM mission. In the beam of Resolve there is a filter wheel containing \xray{} filters. In the beam also is an active calibration…
The analysis of data from x-ray microcalorimeters requires great care; their excellent intrinsic energy resolution cannot usually be achieved in practice without a statistically near-optimal pulse analysis and corrections for important…
A formalism for treating the pile-up produced in solid-state detectors by laser-driven pulsed x-ray sources has been developed. It allows the direct use of x-ray spectroscopy without artificially decreasing the number of counts in the…
When processing large amounts of data, the rate at which reading and writing can take place is a critical factor. High energy physics data processing relying on ROOT is no exception. The recent parallelisation of LHC experiments' software…
Optical crosstalk seriously limits the photon-counting resolution of silicon photomultipliers. In this work, realistic analytical models to describe the crosstalk effects on the response of these photodetectors are presented and compared…
To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital…
Exotic atom experiments place transition-edge-sensor (TES) microcalorimeter arrays in a high-energy charged particle rich environment. When a high-energy charged particle passes through the silicon substrate of a TES array, a large amount…
The XRISM (X-Ray Imaging and Spectroscopy Mission) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an x-ray microcalorimeter detector, which was…
This proceeding discusses nonequilibrium effects in matter exposed to XUV/X-ray irradiation. When ultrashort, intense XUV/X-ray pulses interact with materials, they trigger a complex sequence of processes, including electronic excitation,…
The applicability of LaBr3:Ce detectors for high count rate {\gamma}-ray spectroscopy is investigated. A 3"x3" LaBr3:Ce detector is used in a test setup with radioactive sources to study the dependence of energy resolution and photo peak…
A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed…
The effects of high pulse intensity and chirp on two-dimensional electronic spectroscopy signals are experimentally investigated in the highly non-perturbative regime using atomic rubidium vapor as clean model system. Data analysis is…
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each…
Amid the demand for densely integrated elements in techniques such as holographic reconfigurable intelligent surfaces (RISs), the mutual coupling effect has gained prominence. By performing a misspecified Cramer-Rao bound analysis within an…
The X-ray Timing Instrument as part of the Neutron Star Interior Composition Explorer has the potential to examine the time-domain properties of compact objects in regimes not explored by previous timing instruments, due to its combination…
The CG-2 beamline at the High Flux Isotope Reactor (HFIR) exhibits a notable discrepancy between observed count rates and the count rates we would expect based on a Monte-Carlo neutron ray-trace simulation. These simulations consistently…