Related papers: A Configurable Ultra-Low Noise Current Source for …
The scalability of most transition-edge sensor arrays is limited by the multiplexing technology which combines their signals over a reduced number of wires and amplifiers. In this Letter, we present and demonstrate a multiplexer design…
Transition-edge sensors (TESs) have the potential to perform electron spectroscopic measurements with far greater measurement rates and efficiencies than can be achieved using existing electron spectrometers. Existing spectrometers filter…
A novel readout architecture that uses multiple non-destructive floating-gate amplifiers to achieve sub-electron readout noise in a thick, fully-depleted silicon detector is presented. This Multi-Amplifier Sensing Charge-Coupled Device…
Time-resolved photoelectron spectroscopy (trPES) can directly detect transient electronic structure, thus bringing out its promising potential to clarify nonequilibrium processes arising in condensed matters. Here we report the result of…
Superconducting lithographed resonators have a broad range of current and potential applications in the multiplexed readout of cryogenic detectors. Here, we focus on LC bandpass filters with resonances in the 1-5 MHz range used in the…
We present the electro-thermal characterization of transition-edge sensor (TES) detectors suspended on Si membranes fabricated using a silicon-on-insulator (SOI) wafer. The use of an all-silicon fabrication platform, in contrast to the more…
Superconducting transition-edge sensors (TESs) are a type of quantum sensor known for its high single-photon detection efficiency and low background. This makes them ideal for particle physics experiments searching for rare events. In this…
Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20 keV energy range. We are building a TES-based instrument for the…
A radically new CCD development by Marconi Applied Technologies has enabled substantial internal gain within the CCD before the signal reaches the output amplifier. With reasonably high gain, sub-electron readout noise levels are achieved…
The responsivity and noise of a voltage-biased superconducting transition-edge sensor depends strongly on the details of its thermal model, and the simplest theory for TES response assumes a single heat capacity connected to the heat bath.…
The so-called excess noise limits the energy resolution of transition-edge sensor (TES) detectors, and its physical origin has been unclear, with many competing models proposed. Here we present the noise and impedance data analysis of a…
Transition Edge Sensors (TES) are superconducting microcalorimeters that can be used for single-photon detection with extremely low backgrounds. When they are within their superconducting transition region, small temperature fluctuations -…
Transition edge sensors (TES) have the highest reported efficiencies (>98%) for detection of single photons in the visible and near infrared. Experiments in quantum information and foundations of physics that rely critically on this…
The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies…
The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce…
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to…
We report our most recent progress and demonstration of a frequency domain multiplexing (FDM) readout technology for transition-edge sensor (TES) arrays, both of which we have been developing, in the framework of the X-IFU instrument on…
The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama desert in Chile to observe the cosmic microwave background (CMB) radiation with unprecedented sensitivity. Simons Observatory…
Optical transition-edge sensors have shown energy resolution for resolving the number of incident photons at the telecommunication wavelength. Higher energy resolution is required for biological imaging and microscope spectroscopy. In this…
In recent years, audio coding technology has been standardized based on several frameworks that incorporate linear predictive coding (LPC). However, coding the transient signal using frequency-domain LP residual signals remains a challenge.…