Related papers: CMS tracking performance in Run 2 and early Run 3
The era of High-Luminosity Large Hadron Collider will pose unprecedented challenges for detector design and operation. The planned luminosity of the upgraded machine is 5-7.5 x 10$^{34}$ cm$^{-2}$ s$^{-1}$, reaching an integrated luminosity…
The ATLAS experiment at the Large Hadron Collider employs a two-level trigger system to record data at an average rate of 1 kHz from physics collisions, starting from an initial bunch crossing rate of 40 MHz. During the LHC Run 2…
The ATLAS trigger has been used very successfully for the online event selection during the first part of the second LHC run (Run-2) in 2015/16 at a center-of-mass energy of 13 TeV. The trigger system is composed of a hardware Level-1…
The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R\&D program, aiming at using 3D pixel…
The Compact Muon Solenoid (CMS) detector is one of two general-purpose detectors that measure the products of high energy particle interactions in the Large Hadron Collider (LHC) at CERN. The silicon pixel detector is the innermost…
The ALICE experiment at the CERN Large Hadron Collider (LHC) is a multi-purpose particle detector, mainly focused on the study of quark-gluon plasma (QGP) in heavy-ion collisions. In the forward rapidity region, 2.5 $<$ y $<$ 4, ALICE is…
The trigger selection capabilities of the ATLAS detector have been significantly enhanced for the LHC Run- 2 in order to cope with the higher event rates and with the large number of simultaneous interactions (pile-up) per protonproton…
A wealth of physics results have already been obtained from the LHC, due to the excellent performance of the collider and its experiments. Even more results are expected to be achievable in the phase of the high-luminosity LHC (HL-LHC). It…
During the third long shutdown of the CERN Large Hadron Collider, the CMS Detector will undergo a major upgrade to prepare for Phase-2 of the CMS physics program, starting around 2026. The upgraded CMS detector will be read out at an…
These proceedings report on lepton and photon performance results obtained using data recorded in 2015 and 2016 at the LHC by the two experiments ATLAS and CMS. For each particle (electrons, photons and muons), the reconstruction and…
The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of $\mathcal{L}=2\times 10^{34}\mathrm{cm}^{-2}\mathrm{s}^{-1}$ was routinely achieved at the…
The pixel detector is the innermost tracking device in CMS, reconstructing interaction vertices and charged particle trajectories. The sensors located in the innermost layers of the pixel detector must be upgraded for the ten-fold increase…
The LHC detectors are well into their construction phase. The LHC schedule shows first beam to ATLAS and CMS in 2007. Because the LHC accelerator has begun to plan for a ten fold increase in LHC design luminosity (the SLHC or super LHC) it…
This report presents recent results on track reconstruction and alignment with the silicon tracker of the CMS experiment at the LHC, obtained with a full detector simulation. After an overview of the layout of the tracker and its material…
In Run 3 of the LHC the LHCb experiment faces very high data rates containing beauty and charm hadron decays. Thus the task of the trigger is not to select any beauty and charm events, but to select those containing decays interesting for…
During Phase-2 of the LHC, known as the High Luminosity LHC (HL-LHC), the accelerator will increase its instantaneous luminosity to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$, delivering an integrated luminosity of 3000 fb$^{-1}$ over 10 years…
The Resistive Plate Chambers detector system at the CMS experiment at the LHC provides robustness and redundancy to the muon trigger. A total of 1056 double-gap chambers cover the pseudo-rapidity region < 1.6. The main detector parameters…
The status of the CMS experiment is described. After a brief review of the detector design and a short overview of the first 5 years of assembly, the focus of this presentation will be the parallel activities of completing and commissioning…
The Precision Proton Spectrometer (PPS) of the CMS and TOTEM experiments collected 107.7 fb$^{-1}$ in proton-proton (pp) collisions at the LHC at 13 TeV (Run 2). This paper describes the key features of the PPS alignment and optics…
We plan to add high precision tracking- and timing-detectors at z = +/- 240 m to CMS to study exclusive processes p + p -- p + X + p at high luminosity. This enables the LHC to be used as a tagged photon-photon collider, with X = l+l- and…