Related papers: Cryogenic RPWELL: a novel charge-readout element f…
We present for the first time, discharge-free operation at cryogenic conditions of a Resistive-Plate WELL (RPWELL) detector. It is a single-sided Thick Gaseous Electron Multiplier (THGEM) coupled to a readout anode via a plate of high bulk…
The operation of a cryogenic Resistive WELL (RWELL) in liquid argon vapor is reported for the first time. It comprises a Thick Gas Electron Multiplier (THGEM) structure coupled to a resistive Diamond-Like Carbon (DLC) anode deposited on an…
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25…
We present the results of first studies of the Resistive Plate WELL (RPWELL): a single-faced THGEM coupled to a copper anode via a resistive layer of high bulk resistivity. We explored various materials of different bulk resistivity (10^9 -…
Cryogenic versions of Resistive WELL (RWELL) and Resistive Plate WELL (RPWELL) detectors have been developed, aimed at stable avalanche multiplication of ionization electrons in dual-phase TPCs. In the RWELL, a thin resistive layer…
Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements…
Resistive electrodes are used in gaseous detectors to quench electrical discharges. This helps to protect delicate electrodes and readout electronics and to improve the stability of the detector operation. An RPWELL is a THGEM-based WELL…
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9…
We present a new design and assembly procedure of a large-area gas-avalanche Resistive-Plate WELL (RPWELL) detector. A $50\times50 ~\mathrm{cm^2}$ prototype was tested in $\mathrm{80 ~GeV/c}$ muon beam at CERN-SPS, presenting improved…
A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through…
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout…
In this work we investigate three variants of single amplification-stage detector elements; they comprise THGEM electrodes closed at their bottom with metallic or resistive anodes to form WELL-type configurations. We present the results of…
Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based…
Thick Gas Electron Multipliers (THGEMs) have the potential of constituting thin, robust sampling elements in Digital Hadron Calorimetry (DHCAL) in future colliders. We report on recent beam studies of new single- and double-THGEM-like…
Numerical simulations were used to study signal formation in a Thick Gaseous Electron Multiplier (THGEM) and in THGEM -based Thick-WELL (THWELL) and Resistive-Plate WELL (RPWELL) detectors. The signal shapes were simulated in mixtures of…
The $\mu$-RWELL is a single-amplification stage resistive Micro-Pattern Gaseous Detector (MPGD). The detector amplification element is realized with a single copper-clad polyimide foil micro-patterned with a blind hole (well) matrix and…
We present a comparative study of three resistive Micro-Pattern Gaseous Detector (MPGD) technologies - Micromegas, RPWELL, and $\mu\mathrm{-RWELL}$ - with VMM3a based readout, using relativistic muons and pions. The Micromegas and the…
The occurrence of electrical discharges in gas detectors restricts their dynamic range and degrades their performance. Among the different methods developed to mitigate discharge effects, the use of resistive materials in the detector…
Characterization of diamond-like carbon (DLC) coatings at cryogenic temperatures (down to 77 K) is presented, covering the electrical resistivity range of practical interest to gaseous and liquid particle instrumentation: 10^-1-10^5…
The PICOSEC detector concept uses a micro-pattern gaseous detector (MPGD) amplification structure combined with a Cerenkov radiator coated with a semi-transparent photocathode to provide below tens of picosecond-level precision timing…