Related papers: SubZero: Subspace Zero-Shot MRI Reconstruction
Single-shot magnetic resonance (MR) imaging acquires the entire k-space data in a single shot and it has various applications in whole-body imaging. However, the long acquisition time for the entire k-space in single-shot fast spin echo…
General purpose semantic segmentation relies on a backbone CNN network to extract discriminative features that help classify each image pixel into a 'seen' object class (ie., the object classes available during training) or a background…
Lately, deep learning has been extensively investigated for accelerating dynamic magnetic resonance (MR) imaging, with encouraging progresses achieved. However, without fully sampled reference data for training, current approaches may have…
Magnetic resonance imaging (MRI) is known to have reduced signal-to-noise ratios (SNR) at lower field strengths, leading to signal degradation when producing a low-field MRI image from a high-field one. Therefore, reconstructing a…
Recent zero-shot learning (ZSL) approaches have integrated fine-grained analysis, i.e., fine-grained ZSL, to mitigate the commonly known seen/unseen domain bias and misaligned visual-semantics mapping problems, and have made profound…
Self-supervised learning (SSL) methods have achieved remarkable success in learning image representations allowing invariances in them - but therefore discarding transformation information that some computer vision tasks actually require.…
Magnetic Resonance Imaging (MRI) acquisitions require extensive scan times, limiting patient throughput and increasing susceptibility to motion artifacts. Accelerated parallel MRI techniques reduce acquisition time by undersampling k-space…
Purpose: To develop a strategy for training a physics-guided MRI reconstruction neural network without a database of fully-sampled datasets. Theory and Methods: Self-supervised learning via data under-sampling (SSDU) for physics-guided deep…
Self-supervised Learning (SSL) including the mainstream contrastive learning has achieved great success in learning visual representations without data annotations. However, most of methods mainly focus on the instance level information…
Object classes that surround us have a natural tendency to emerge at varying levels of abstraction. We propose a Bayesian approach to zero-shot learning (ZSL) that introduces the notion of meta-classes and implements a Bayesian hierarchy…
Zero shot learning (ZSL) aims to recognize unseen classes by exploiting semantic relationships between seen and unseen classes. Two major problems faced by ZSL algorithms are the hubness problem and the bias towards the seen classes.…
This paper introduces a novel approach to improving the training stability of self-supervised learning (SSL) methods by leveraging a non-parametric memory of seen concepts. The proposed method involves augmenting a neural network with a…
Reconstruction and joint embedding have emerged as two leading paradigms in Self Supervised Learning (SSL). Reconstruction methods focus on recovering the original sample from a different view in input space. On the other hand, joint…
In medical image analysis, the cost of acquiring high-quality data and their annotation by experts is a barrier in many medical applications. Most of the techniques used are based on supervised learning framework and need a large amount of…
High-resolution Magnetic Resonance Imaging (MRI) is vital for clinical diagnosis but limited by long acquisition times and motion artifacts. Super-resolution (SR) reconstructs low-resolution scans into high-resolution images, yet existing…
Modern consumer cameras commonly employ the rolling shutter (RS) imaging mechanism, via which images are captured by scanning scenes row-by-row, resulting in RS distortion for dynamic scenes. To correct RS distortion, existing methods adopt…
In zero-shot learning (ZSL) community, it is generally recognized that transductive learning performs better than inductive one as the unseen-class samples are also used in its training stage. How to generate pseudo labels for unseen-class…
Diffusion models have recently demonstrated considerable advancement in the generation and reconstruction of magnetic resonance imaging (MRI) data. These models exhibit great potential in handling unsampled data and reducing noise,…
Magnetic resonance imaging (MRI) is known to be a slow imaging modality and undersampling in k-space has been used to increase the imaging speed. However, image reconstruction from undersampled k-space data is an ill-posed inverse problem.…
Self-Supervised Learning (SSL) is at the core of training modern large machine learning models, providing a scheme for learning powerful representations that can be used in a variety of downstream tasks. However, SSL strategies must be…