English
Related papers

Related papers: A method to specify X-ray mirrors for nanoprobe be…

200 papers

We have developed an improved method of time-resolved x-ray reflectivity (XRR) using monochromatic synchrotron radiation. Our method utilizes a polycapillary x-ray optic to create a range of incident angles and an area detector to collect…

Materials Science · Physics 2019-03-27 Howie Joress , Shane Quinlan Arlington , Timothy P. Weihs , Joel D. Brock , Arthur Woll

Measuring the diffuse, highly-ionized baryonic content in galactic halos and the intergalactic medium through soft x-ray absorption spectroscopy of active galactic nuclei is a main scientific objective of the Lynx X-ray Observatory mission…

Instrumentation and Methods for Astrophysics · Physics 2022-06-17 Jake A. McCoy

The research and development of silicon-based X-ray fluorescence detectors achieved its submicron sensitivity. Its initial use is intended for in-situ beam monitoring at advanced light-source facilities. The effectively functioning…

Accelerator Physics · Physics 2018-11-13 Phil S. Yoon

An analytical approach describing properties of focused partially coherent X-ray beams is presented. The method is based on the results of statistical optics and gives both the beam size and transverse coherence length at any distance…

Optics · Physics 2014-11-06 A. Singer , I. A. Vartanyants

This paper presents the first-principle design approach for X-ray active optics, using the simulation-modulation cycle in place of the measurement-modulation feedback loops used in traditional active optics. Hence, the new active optics…

Optics · Physics 2024-01-09 Dezhi Diao , Han Dong , Fugui Yang , Ming Li , Weifan Sheng , Xiaowei Zhang

Some high-energy experiments have suffered from synchrotron-radiation background. As a measure, we have developed a new calculation method of synchrotron radiation based on a real beam orbit, aiming at quantitative estimations and the…

Accelerator Physics · Physics 2016-09-08 Tetsuo Abe , Hitoshi Yamamoto

Synchrotron light sources can provide the required spatial coherence, stability and control that is required to support the development of advanced lithography at the extreme ultraviolet and soft X-ray wavelengths that are relevant to…

Synchrotron radiation facilities provide highly polarized X-ray beams across a wide energy range. However, the exact type and degree of polarization varies according to the beamline and experimental setup. To accurately determine the angle…

Instrumentation and Detectors · Physics 2024-05-31 L. Manzanillas , J. M. Ablett , M. Choukroun , F. J. Iguaz , J. P. Rueff

We describe a new technology for the fabrication of inexpensive high-quality mirrors. We begin by chemically producing a large number of metallic nanoparticles coated with organic ligands. The particles are then spread on a liquid substrate…

Aligning beamlines at synchrotron light sources is a high-dimensional, expensive-to-sample optimization problem, as beams are focused using a series of dynamic optical components. Bayesian Optimization is an efficient machine learning…

Accelerator Physics · Physics 2024-08-14 Megha R. Narayanan , Thomas W. Morris

The synchrotron light source, a cutting-edge large-scale user facility, requires autonomous synchrotron beamline operations, a crucial technique that should enable experiments to be conducted automatically, reliably, and safely with minimum…

Computer Vision and Pattern Recognition · Computer Science 2025-06-03 Baolu Li , Hongkai Yu , Huiming Sun , Jin Ma , Yuewei Lin , Lu Ma , Yonghua Du

We present in this paper an update on the design of BEaTriX (Beam Expander Testing X-ray facility), an X-ray apparatus to be realized at INAF/OAB and that will generate an expanded, uniform and parallel beam of soft X-rays. BEaTriX will be…

Instrumentation and Methods for Astrophysics · Physics 2016-10-03 Carlo Pelliciari , Daniele Spiga , Elisa Bonnini , Elisa Buffagni , Claudio Ferrari , Giovanni Pareschi , Gianpiero Tagliaferri

Multilayer X-ray mirrors consist of a coating of a large number of alternate layers of high Z and low Z materials with a typical thickness of 10-100 Angstrom, on a suitable substrate. Such coatings play an important role in enhancing the…

X-ray 3D tomography is So far limited to micron resolution because of the large focusing spot of the focused electron beam on the metal target. Here, we proposed a nanofocous X-ray 3D tomography system based on focused electrons from…

Instrumentation and Detectors · Physics 2018-03-14 Gholamreza Shayeganrad

Moving towards significantly smaller nanostructures, direct structuring techniques such as electron beam lithography approach fundamental limitations in feature size and aspect ratios. Application of nanostructures like diffractive X-ray…

A relatively simple and accurate analytical model for studying the reflectivity of neutron multilayer monochromators and supermirrors is proposed. Design conditions that must be fulfilled in order to reach the maximum reflectivity are…

Instrumentation and Detectors · Physics 2013-11-20 S. Masalovich

Ptychography has become prominent at synchrotron facilities worldwide for characterizing biological and material specimens' topological structures and properties at the nanometer or atomic scale, due to its lens - less, highly quantitative…

Image and Video Processing · Electrical Eng. & Systems 2025-01-28 Tao Liu , Bingyang Wang , JiangTao Zhao , Maik Kahnt , Fucai Zhang

Two recently commissioned infrared beamlines on the 1.4 bending magnet port at the Advanced Light Source, LBNL, are described. Using a synchrotron as an IR source provides three primary advantages: increased brightness, very fast light…

Materials Science · Physics 2007-05-23 Michael C. Martin , Wayne R. McKinney

X-ray microtomography at synchrotron sources is fundamentally limited by the high radiation dose applied to the samples, which restricts investigations to non-native tissue states and thereby compromises the biological relevance of the…

The resolution function of a spectrometer based on a strongly bent single crystal (bending radius of 10 cm or less) is evaluated. It is shown that the resolution is controlled by two parameters, (i) the ratio of the lattice spacing of the…

Instrumentation and Detectors · Physics 2020-09-21 Vladimir Kaganer , Ilia Petrov , Liubov Samoylova