English
Related papers

Related papers: Gas Counters Aging for Dummies

200 papers

Complementary metal-oxide-semiconductor (CMOS) detectors are a competitive choice for current and upcoming astronomical missions. To understand the performance variations of CMOS detectors in space environment, we investigate the total…

Instrumentation and Methods for Astrophysics · Physics 2024-03-26 Mengxi Chen , Zhixing Ling , Mingjun Liu , Qinyu Wu , Chen Zhang , Jiaqiang Liu , Zhenlong Zhang , Weimin Yuan , Shuang-Nan Zhang

Time of flight of a minimum ionizing particle along a fixed base has been measured with a 100 ps accuracy by means of a Dielectric Resistive Plate Chamber (DRPC) with 4 x 0.3 mm gas gaps. DRPC timing characteristics have been studied with…

Instrumentation and Detectors · Physics 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , V. Plotnikov , A. Smirnitsky , K. Voloshin

Direction-sensitive WIMP dark matter searches may help overcome the challenges faced by direct dark matter detection experiments. In particular, directional detectors should be able to clearly differentiate a dark matter signal from…

Instrumentation and Detectors · Physics 2014-02-04 Steven Ross

Working gas components significantly impact the performance of gaseous detectors. A fast-timing Micromegas detector with two-stage amplification is prone to notable deterioration of uniformity when scaled up. This paper presents a…

Instrumentation and Detectors · Physics 2024-11-08 Yue Meng , Xu Wang , Jianbei Liu , Ming Shao , Zhiyong Zhang , Yi Zhou

Currently a revolution is taking place in the development of gaseous detectors of photons and particles. Parallel plate-type and wire-type detectors which dominated for years in high energy and space flight experiments are now being…

Instrumentation and Detectors · Physics 2017-08-23 T. Francke , V. Peskov

The ICARUS detector is a liquid argon time projection chamber. It provides three dimensional imaging and calorimetry of ionizing particles over a large volume, with high granularity. Its Physics program includes the study of atmospheric,…

High Energy Physics - Experiment · Physics 2019-08-14 Javier Rico

Spherical proportional counters (SPCs) are gaseous particle detectors sensitive to single ionization electrons in their target media, with large detector volumes and low background rates. The $\mbox{NEWS-G}$ collaboration employs this…

Performance of the known porous multiwire radiation detectors is stable in the mode of pulsed voltage supply. The results of the study of multiwire porous detector operated at constant voltage supply are presented in this article. It is…

Instrumentation and Detectors · Physics 2007-05-23 M. P. Lorikyan

The triple GEM detector is a micropattern gas detector which consists of a primary ionisation gap and three consecutive gas electron multiplier (GEM) foils. A printed circuit board with readout strips detects the current induced by the…

High Energy Physics - Experiment · Physics 2009-10-31 M. Ziegler , P. Sievers , U. Straumann

In high energy physics experiments, the numerical estimation of primary ionization is crucial. An advance study on primary ionization can help in minimizing the effects such as electrical discharges that can damage the gaseous detectors…

High Energy Physics - Experiment · Physics 2024-07-08 R. Kanishka

With increasing interest in high-speed imaging should come an increased interest in the response times of our scanning transmission electron microscope (STEM) detectors. Previous works have previously highlighted and contrasted performance…

Instrumentation and Detectors · Physics 2023-08-09 Tiarnan Mullarkey , Matthew Geever , Jonathan J. P. Peters , Ian Griffiths , Peter D. Nellist , Lewys Jones

A set of classical multi-wire proportional chambers were designed and constructed with the main purpose of efficient cosmic muon detection. These detectors are relatively simple to construct, and at the same time are low cost, making them…

Instrumentation and Detectors · Physics 2015-09-30 Dezső Varga , Zoltán Gál , Gergő Hamar , Janka Sára Molnár , Éva Oláh , Péter Pázmándi

A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4\pi$. The high density of hits on a given particle track facilitates the task of pattern…

Aging effects in the relaxations of conductivity of a two-dimensional electron system in Si have been studied as a function of carrier density. They reveal an abrupt change in the nature of the glassy phase at the metal-insulator transition…

Strongly Correlated Electrons · Physics 2009-11-13 J. Jaroszynski , Dragana Popovic

Radioactivity is understood to be described by a Poisson process, yet some measurements of nuclear decays appear to exhibit unexpected variations. Generally, the isotopes reporting these variations have long half lives, which are plagued by…

Building performance has been shown to degrade significantly after commissioning, resulting in increased energy consumption and associated greenhouse gas emissions. Continuous Commissioning using existing sensor networks and IoT devices has…

Signal Processing · Electrical Eng. & Systems 2022-08-31 Rony Shohet , Mohamed Kandil , Y. Wang , J. J. McArthur

Developed right at the beginning of the space age in the 1940s, the proportional counter was the first detector used in X-ray astronomy and stayed its workhorse for almost four decades. Although the principle of such a detector seems to be…

Instrumentation and Methods for Astrophysics · Physics 2023-04-05 Sebastian Diebold

A Time Projection Chamber (TPC) using micro-pattern gas detectors is planned as the main tracking device for a detector at the next Linear Collider. A novel support structure for Gas Electron Multipliers (GEMs), which minimizes the material…

Instrumentation and Detectors · Physics 2015-06-17 T. Behnke , F. Müller , A. Münnich , K. Zenker

In experiments searching for rare signals, background events from the detector itself are some of the major factors limiting search sensitivity.Screening for ultra-low radioactive detector materials is becoming ever more essential. We…

Instrumentation and Detectors · Physics 2021-12-24 Haiyan Du , Chengbo Du , Karl Giboni , Ke Han , Shengming He , Liqiang Liu , Yue Meng , Shaobo Wang , Tao Zhang , Li Zhao , Jifang Zhou

The new observation of X(1835)is reported using 58 million $\jpsi$ events collected at BES II detector. We also present the measurements of J/\Psi and eta_c decays, of them some are the first measurements and some improve the precision in…

High Energy Physics - Experiment · Physics 2009-11-11 Shuangshi Fang
‹ Prev 1 4 5 6 7 8 10 Next ›