Related papers: Two-Stage Cryogenic HEMT Based Amplifier For Low T…
We demonstrate that current and planned underground neutrino experiments could offer a powerful probe of few-MeV dark matter when combined with a nearby high-intensity low-to-medium energy electron accelerator. This experimental setup, an…
We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal,…
In order to fully reconstruct to the reaction e+e- to e+e- gamma-gamma in the energy region of the phi meson production, new detectors along the DAFNE beam line have to be installed in order to detect the scattered e+e-. The High Energy…
We propose a time-resolved optical measurement scheme for sampling transient charge and spin currents in a bulk centrosymmetric semiconductor. The technique relies on emission of second harmonic light triggered by a pulsed below-gap optical…
In the strive for scalable quantum processors, significant effort is being devoted to the development of cryogenic classical hardware for the control and readout of a growing number of qubits. Here we report on a cryogenic circuit…
Dark matter is five times more abundant than ordinary visible matter in our Universe. While laboratory searches hunting for dark matter have traditionally focused on the electroweak scale, theories of low mass hidden sectors motivate new…
The detection of low-energy deposition in the range of sub-eV through ionization using germanium (Ge) with a bandgap of $\sim$0.7 eV requires internal amplification of charge signal. This can be achieved through high electric field which…
Low-temperature cryogenics open the door for a range of interesting technologies based on features like superconductivity and superfluidity, low-temperature phase transitions or the low heat capacity of non-metals in the milli-Kelvin range.…
Most microwave readout architectures in quantum computing or sensing rely on a semiconductor amplifier at 4 K, typically a high-electron mobility transistor (HEMT). Despite its remarkable noise performance, a conventional HEMT dissipates…
The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) and the EURECA (European Underground Rare Event Calorimeter Array) experiments are direct dark matter search experiments where cryogenic detectors are used to detect…
Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…
An unconventional method of continuous solid-state cryogenic cooling utilizing the electron subband degeneracy of semiconductor heterostructures is proposed in this Letter. An electrostatic heat pump is modeled, which employs subband…
In this paper, a two-stage ultra-low-power operational amplifier is designed, and a comparative analysis of the proposed subthreshold complementary amplifier is presented between 180nm, 90nm, and 45nm CMOS technology. The proposed…
This paper presents progress on the development of a cryostat intended to improve upon the low-energy threshold (below 0.5 keV) of p-type point contact germanium gamma-ray spectrometers. Ultra-low energy thresholds are important in the…
A simple hole-type secondary scintillation structure (2 mm-hole, 5 mm-pitch, 5 mm-thickness) is introduced and its operation demonstrated in pure xenon in the pressure range 2-10 bar. The new device, characteristically translucent, has been…
A new detector is being developed at the National Superconducting Cyclotron Laboratory (NSCL) to measure low energy charged-particles from beta-delayed particle emission. These low energy particles are very important for nuclear…
High light collection efficiency is an important requirement in any application of scintillation detectors. The purpose of this study is to investigate the possibility for improving this parameter in cryogenic scintillation bolometers,…
The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 - 540 GHz frequency range. EXCLAIM uses…
CUPID is a next-generation neutrinoless double-beta decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In…
Low-temperature calorimeters based on a readout via Transition Edge Sensors (TESs) and operated below $100$ mK are well suited for rare event searches with outstanding resolution and low thresholds. We present first experimental results…