Related papers: CMS ECAL VFE design, production and testing
3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC upgrade of the ATLAS pixel detector. 3D detectors are already in use today in the ATLAS IBL and AFP experiments. These are…
We present the development of the FBCM23 ASIC designed for the Phase-II upgrade of the Fast Beam Condition Monitoring (FBCM) system built at the CMS experiment which will replace the present luminometer based on the BCM1F ASIC [1]. The FBCM…
The design of a radiation-hard dual channel 12-bit 40 MS/s pipeline ADC with extended dynamic range is presented, for use in the readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider. The…
A 64-channel mixed-mode ASIC, suitable for particle detectors of large dynamic range and high capacitance up to hundreds of pF, is presented here. Each channel features an analogue front-end for signal amplification and filtering, and a…
Joint progresses in Cd(Zn)Te detectors, microelectronics and interconnection technologies open the way for a new generation of instruments for physics and astrophysics applications in the energy range from 1 to 1000 keV. Even working…
The CALICE collaboration conducts calorimeter R&D for highly granular calorimeters, mainly for their application in detectors for a future lepton collider at the TeV scale. The activities ranges from generic R&D with small devices up to…
The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future…
The High-Granularity Calorimeter (HGCAL) will replace the current CMS Endcap Calorimeter during Long-Shutdown 3. The Endcap Concentrator (ECON) ASICs represent key elements in the readout chain, processing trigger (ECON-T) and data (ECON-D)…
A radiation-hard quad-channel 12-bit 40 MSPS pipeline analog-to-digital converter (ADC) has been designed for the trigger readout electronics Phase-I upgrade of the ATLAS Liquid Argon calorimeter, at the CERN Large Hadron Collider. The…
The High Luminosity Large Hadron Collider (HL-LHC) at CERN is expected to collide protons at a center-of-mass energy of 14 TeV and to reach the unprecedented peak instantaneous luminosity of $7.5 \times 10^{34} \text{cm}^{-2} \text{s}^{-1}$…
A new electromagnetic calorimeter (ECAL) consisting of 1596 lead tungstate PbWO$_{\rm 4}$ scintillating crystals has been fabricated and installed in the experimental Hall D at Jefferson Lab (JLab). The high-granularity, high-resolution…
The FCAL collaboration is preparing large-scale prototypes of special calorimeters to be used in the very forward region at future electron-positron colliders for instant luminosity measurement and a precise measurement of integrated…
This paper presents mechanical R&D for the CALICE Silicon-tungsten electromagnetic calorimeter. After the physics ECAL prototype, tested in 2006 (DESY-CERN), 2007 (CERN), 2008 (FNAL) and before the design of different "modules 0" (barrel…
The CALICE collaboration is currently developing engineering prototypes of electromagnetic and hadronic calorimeters for a future linear collider detector. This detector is designed to be used in particle-flow based event reconstruction. In…
Analysis of the CMS data and the simulation prediction based on these results indicate that the performance of the current scintillators in the CMS Hadron Endcap Calorimeter (HE) tiles will degrade dramatically in the High Luminosity LHC…
To face the higher levels of radiation due to the 10-fold increase in integrated luminosity during the High-Luminosity LHC, the CMS detector will replace the current Calorimeter Endcap (CE) using the High-Granularity Calorimeter (HGCAL)…
Future experiments of nuclear and particle physics are moving towards the high luminosity regime, in order to access suppressed processes like rare B decays or exotic charmonium resonances. In this scenario, high rate capability is a key…
Two finely segmented and very compact calorimeters are foreseen for the instrumentation of the very forward region of the ILC and the CLIC detectors; a luminometer to measure the rate of low angle Bhabha scattering events with a precision…
The TileCal is the main hadronic calorimeter of ATLAS and it covers the central part of the detector ($|\eta|$ < 1.6). The energy deposited by the particles in TileCal is read out by approximately 10,000 channels. The signal provided by the…
An onboard calibration circuit has been designed for the front-end electronics (FEE) of DAMPE BGO Calorimeter. It is mainly composed of a 12 bit DAC, an operation amplifier and an analog switch. Test results showed that a dynamic range of 0…