Quantitative $T_1$ mapping by MRI is an increasingly important tool for clinical assessment of cardiovascular diseases. The cardiac $T_1$ map is derived by fitting a known signal model to a series of baseline images, while the quality of…

Image and Video Processing · Electrical Eng. & Systems 2024-06-24 Yi Zhang , Yidong Zhao , Lu Huang , Liming Xia , Qian Tao

Quantitative cardiac magnetic resonance imaging (MRI) enables non-invasive myocardial tissue characterization but relies on robust motion correction within these variable-length, variable-contrast image sequences. Groupwise registration,…

Image and Video Processing · Electrical Eng. & Systems 2026-05-12 Yi Zhang , Yidong Zhao , Tijmen Toxopeus , Maša Božić-Iven , Sebastian Weingärtner , Qian Tao

Cardiac T1 mapping can evaluate various clinical symptoms of myocardial tissue. However, there is currently a lack of effective, robust, and efficient methods for motion correction in cardiac T1 mapping. In this paper, we propose a deep…

Computer Vision and Pattern Recognition · Computer Science 2024-10-16 Chiyi Huang , Longwei Sun , Dong Liang , Haifeng Liang , Hongwu Zeng , Yanjie Zhu

Low-rank and sparse decompositions and robust PCA (RPCA) are highly successful techniques in image processing and have recently found use in groupwise image registration. In this paper, we investigate the drawbacks of the most common…

Computer Vision and Pattern Recognition · Computer Science 2020-01-13 Roland Haase , Stefan Heldmann , Jan Lellmann

Multiparametric mapping MRI has become a viable tool for myocardial tissue characterization. However, misalignment between multiparametric maps makes pixel-wise analysis challenging. To address this challenge, we developed a generalizable…

Image and Video Processing · Electrical Eng. & Systems 2025-10-31 Xinqi Li , Yi Zhang , Li-Ting Huang , Hsiao-Huang Chang , Thoralf Niendorf , Min-Chi Ku , Qian Tao , Hsin-Jung Yang

Motion correction of dynamic contrast enhanced magnetic resonance images (DCE-MRI) is a challenging task, due to changes in image appearance. In this study a groupwise registration, using a principle component analysis (PCA) based metric,1…

Image and Video Processing · Electrical Eng. & Systems 2019-08-23 Mariëlle J. A. Jansen , Wouter B. Veldhuis , Maarten S. van Leeuwen , Josien P. W. Pluim

Motion free reconstruction of compressively sampled cardiac perfusion MR images is a challenging problem. It is due to the aliasing artifacts and the rapid contrast changes in the reconstructed perfusion images. In addition to the…

Image and Video Processing · Electrical Eng. & Systems 2019-04-11 Abdul Haseeb Ahmed , Ijaz M. Qureshi

T1 mapping is a quantitative magnetic resonance imaging (qMRI) technique that has emerged as a valuable tool in the diagnosis of diffuse myocardial diseases. However, prevailing approaches have relied heavily on breath-hold sequences to…

Image and Video Processing · Electrical Eng. & Systems 2023-08-23 Eyal Hanania , Ilya Volovik , Lilach Barkat , Israel Cohen , Moti Freiman

Magnetic resonance imaging (MRI) is a non-invasive medical imaging technique offering high-resolution 3D images and valuable insights into human tissue conditions. Even at present, the refinement of denoising methods for MRI remains a…

Image and Video Processing · Electrical Eng. & Systems 2023-08-29 Shiao Li

Principal Component Analysis (PCA) is the most widely used tool for linear dimensionality reduction and clustering. Still it is highly sensitive to outliers and does not scale well with respect to the number of data samples. Robust PCA…

Computer Vision and Pattern Recognition · Computer Science 2015-04-24 Nauman Shahid , Vassilis Kalofolias , Xavier Bresson , Michael Bronstein , Pierre Vandergheynst

Medical image registration is a fundamental task in medical image analysis, enabling the alignment of images from different modalities or time points. However, intensity inconsistencies and nonlinear tissue deformations pose significant…

Computer Vision and Pattern Recognition · Computer Science 2026-04-23 Eytan Kats , Christoph Grossbroehmer , Ziad Al-Haj Hemidi , Fenja Falta , Wiebke Heyer , Mattias P. Heinrich

Robust Principal Component Analysis (RPCA) is a fundamental technique for decomposing data into low-rank and sparse components, which plays a critical role for applications such as image processing and anomaly detection. Traditional RPCA…

Machine Learning · Computer Science 2024-12-20 Kexin Li , You-wei Wen , Xu Xiao , Mingchao Zhao

Percutaneous Coronary Intervention (PCI) is a minimally invasive procedure that improves coronary blood flow and treats coronary artery disease. Although PCI typically requires 2D X-ray angiography (XRA) to guide catheter placement at…

Image and Video Processing · Electrical Eng. & Systems 2025-06-02 Peng Qi , Wenxi Qu , Tianliang Yao , Haonan Ma , Dylan Wintle , Yinyi Lai , Giorgos Papanastasiou , Chengjia Wang

Quantification of cardiac motion with cine Cardiac Magnetic Resonance Imaging (CMRI) is an integral part of arrhythmogenic right ventricular cardiomyopathy (ARVC) diagnosis. Yet, the expert evaluation of motion abnormalities with CMRI is a…

Image and Video Processing · Electrical Eng. & Systems 2023-11-27 Laura Alvarez-Florez , Jörg Sander , Mimount Bourfiss , Fleur V. Y. Tjong , Birgitta K. Velthuis , Ivana Išgum

We present a new technique called contrastive principal component analysis (cPCA) that is designed to discover low-dimensional structure that is unique to a dataset, or enriched in one dataset relative to other data. The technique is a…

Machine Learning · Statistics 2017-11-23 Abubakar Abid , Martin J. Zhang , Vivek K. Bagaria , James Zou

Robust principal component analysis (RPCA) is a widely used technique for recovering low-rank structure from matrices with missing entries and sparse, possibly large-magnitude corruptions. Although numerous algorithms achieve accurate point…

Methodology · Statistics 2026-03-17 Liangliang Yuan , Lei Wang , Quan Kong , Liuhua Peng

Diffeomorphic image registration is a commonly used method to deform one image to resemble another. While warping a single image to another is useful, it can be advantageous to warp multiple images simultaneously, such as in tracking the…

Computer Vision and Pattern Recognition · Computer Science 2024-03-26 Sean Rendell , Jinming Duan

Pretrained segmentation models for cardiac magnetic resonance imaging (MRI) struggle to generalize across different imaging sequences due to significant variations in image contrast. These variations arise from changes in imaging protocols,…

Computer Vision and Pattern Recognition · Computer Science 2025-09-01 Yidong Zhao , Peter Kellman , Hui Xue , Tongyun Yang , Yi Zhang , Yuchi Han , Orlando Simonetti , Qian Tao

Principal component analysis (PCA) frequently suffers from the disturbance of outliers and thus a spectrum of robust extensions and variations of PCA have been developed. However, existing extensions of PCA treat all samples equally even…

Machine Learning · Computer Science 2021-03-23 Rui Zhang , Hongyuan Zhang , Xuelong Li

Diffusion tensor based cardiovascular magnetic resonance (DT-CMR) offers a non-invasive method to visualize the myocardial microstructure. With the assumption that the heart is stationary, frames are acquired with multiple repetitions for…