Related papers: Development and validation of a measurement-driven…
Inter-crystal scattering (ICS) in Positron Emission Tomography (PET) is commonly regarded as a degradation effect that might compromise the image spatial resolution. In parallel, the inclusion of ICS events has also been recognized as a…
A new generation of ultra-low-background scintillator-based detectors aims to study solar neutrinos and search for dark matter and new physics beyond the Standard Model. These optical, non-imaging detectors generally contain a "fiducial…
A PET scanner based on silicon photomultipliers (SiPMs) has been widely used as an advanced nuclear medicine imaging technique that yields quantitative images of regional in vivo biology and biochemistry. The compact size of the SiPM allows…
Scattered coincidences introduce quantitative bias in positron emission tomography (PET) and must be compensated during reconstruction. Conventional scatter estimates typically rely on simplified cylindrical scanner models that omit…
A high sensitivity Cardiac SPECT system using curved crystals with pinhole collimation was proposed previously (Dey, IEEE TNS 2012, Bhusal et al, Med. Phys. 2019). Here, we hypothesize that a high curvature hemi-ellipsoid detector results…
We developed an event reconstruction algorithm, applicable to large liquid scintillator detectors, built primarily upon neutron calibration data. We employ a likelihood method using photon detection time and charge information from…
Imaging reconstruction of interferometric data is a hard ill-posed inverse problem. Its difficulty is increased when observing the Galactic Center, which is obscured by a scattering screen. This is because the scattering breaks the…
Compton cameras are radiation detectors that provide spatial information on the origin of the {\gamma}-ray sources based on the Compton scattering effect. Many applications require these detectors to be used at high counting rate. As such,…
Neutron detection provides an effective method to detect, locate, and characterize sources of interest to nuclear security applications. Current neutron imaging systems based on double-scatter kinematic reconstruction provide good signal…
In CLEAN (Cryogenic Low Energy Astrophysics with Noble gases), a proposed neutrino and dark matter detector, background discrimination is possible if one can determine the location of an ionizing radiation event with high accuracy. We…
In spring 2019 the international atomic energy agency (IAEA) has run a public competition to look at tomographic reconstruction algorithms for its PGET detector, used to determine activity levels in nuclear reactors spent fuel rods. The…
We investigate five different models to reconstruct the 3D $\gamma$-ray hit coordinates in five large \lacls monolithic crystals optically coupled to pixelated silicon photomultipliers. These scintillators have a base surface of 50 $\times$…
We have developed a neural network model to perform event reconstruction of Compton telescopes. This model reconstructs events that consist of three or more interactions in a detector. It is essential for Compton telescopes to determine the…
This article presents a physics-informed deep learning method for the quantitative estimation of the spatial coordinates of gamma interactions within a monolithic scintillator, with a focus on Positron Emission Tomography (PET) imaging. A…
In scintillation detector, scintillation crystals are typically made into 2-dimension modular array. The location of incident gamma-ray need be calibrated due to spatial response nonlinearity. Generally, position histograms, the…
Inverse Compton scattering (ICS) is a unique mechanism for producing fast pulses - picosecond and below - of bright X- to gamma-rays. These nominally narrow spectral bandwidth electromagnetic radiation pulses are efficiently produced in the…
JSNS$^2$ searches for short baseline neutrino oscillations with a baseline of 24~meters and a target of 17~tonnes of the Gd-loaded liquid scintillator. The correct algorithm on the event reconstruction of events, which determines the…
An algorithm for determining crystal structures from diffraction data is described which does not rely on the usual Fourier-space formulations of atomicity. The new algorithm implements atomicity constraints in real-space, as well as…
The high cost and low image quality traditionally associated with proton computed tomography (pCT) have prevented it from seeing significant use in clinical settings. A cheap, compact, high-density scintillating glass detector capable of…
Plastic scintillators are widely used as particle detectors in many fields, mainly, medicine, particle physics and astrophysics. Traditionally, they are coupled to a photo-multplier (PMT) but now silicon photo-multipliers (SiPM) are…