English
Related papers

Related papers: A Finely Segmented Semi-Monolithic Detector tailor…

200 papers

Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…

Instrumentation and Detectors · Physics 2022-11-17 Florian Mueller , Stephan Naunheim , Yannick Kuhl , David Schug , Torsten Solf , Volkmar Schulz

The integration of PET into MRI to form a hybrid system requires often compromises for both subsystems. For example, the integration might come at the cost of a reduced PET detector height or a reduced MRI examination volume diameter. Here,…

Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and…

Instrumentation and Detectors · Physics 2019-09-19 J. M. C. Brown , S. E. Brunner , D. R. Schaart

Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…

Instrumentation and Detectors · Physics 2025-02-12 Shiv K. Subedi , Simon R. Cherry , Yi Qiang , Peng Peng

PET provides in vivo molecular and functional imaging capability that is crucial to studying the interaction of plant with changing environment at the whole-plant level. We have developed a dedicated plant PET imager that features high…

Instrumentation and Detectors · Physics 2014-09-22 Qiang Wang , Aswin J. Mathews , Ke Li , Jie Wen , Sergey Komarov , Joseph A. O'Sullivan , Yuan-Chuan Tai

Objective. This study investigates the best achievable performance of a brain-dedicated PET system with high resolution and sensitivity by evaluating different detector configurations, while maintaining a practical system design suitable…

Medical Physics · Physics 2026-02-26 Yuemeng Feng , Lisa Blackberg , Arkadiusz Sitek , Hamid Sabet

The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…

This article presents a physics-informed deep learning method for the quantitative estimation of the spatial coordinates of gamma interactions within a monolithic scintillator, with a focus on Positron Emission Tomography (PET) imaging. A…

The aim of this work is to show the potential capabilities of monolithic crystals coupled to large SiPM arrays, to be considered as detector blocks for PET scanners enabling Time Of Flight (TOF) capabilities. Monolithic blocks allow one to…

The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment…

Over the last decade one of the most significant technological advances made in the field of radiation detectors for nuclear medicine was the development of Silicon Photomultipler (SiPM) sensors. At present a only small number of SiPM based…

Instrumentation and Detectors · Physics 2020-08-03 Jeremy M. C. Brown

Monolithic crystals are examined as an alternative to segmented scintillator arrays in positron emission tomography (PET). Monoliths provide good energy, timing and spatial resolution including intrinsic depth of interaction (DOI) encoding.…

Medical Physics · Physics 2018-12-05 Florian Müller , David Schug , Patrick Hallen , Jan Grahe , Volkmar Schulz

This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration…

In this study, we propose a fast implementation of a Maximum Likelihood Positioning (MLP) algorithm to estimate the energy and identify the active scintillator pixel in staggered layer scintillation detectors for PET. The staggered layer…

Presice measurements of the photons conversion points in the scintillators are required to achieve a high spatial resolution of the PET system. I have developed a new method of reconstruction of the depth-of-interaction information for PET…

Instrumentation and Detectors · Physics 2018-05-18 Andrei Yu. Semenov

Positron Emission Tomography (PET) enables functional imaging of deep brain structures, but the bulk and weight of current systems preclude their use during many natural human activities, such as locomotion. The proposed long-term solution…

Robotics · Computer Science 2023-12-01 Junxiang Wang , Ti Wu , Iulian I. Iordachita , Peter Kazanzides

Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…

Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic…

A mini-PET style detector system is being developed for a plant imaging application with a compact array of silicon photomultipliers (SiPM) replacing position sensitive photomultipliers (PSPMT). In addition to compactness, the use of SiPMs…

The TT-PET collaboration is developing a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on…

‹ Prev 1 2 3 10 Next ›