English
Related papers

Related papers: Design considerations for the optimization of {\la…

200 papers

Cryogenic macro-calorimeters instrumented with NTD thermistors have been developed for several decades. The choice of the optimal bias current is crucial for a proper operation of these detectors, both in terms of energy resolution and…

Superconducting quantum interference devices (SQUIDs) are exceptionally sensitive magnetometers capable of detecting weak magnetic fields. Miniaturizing these devices and integrating them onto scanning probes enables high-resolution imaging…

The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) is a quantum sensor in which a quasi-1D quantum gas images electromagnetic fields emitted from a nearby sample. We report improvements to the microscope. Cryogen usage is reduced…

Atomic Physics · Physics 2021-03-10 Stephen F. Taylor , Fan Yang , Brandon A. Freudenstein , Benjamin L. Lev

Membrane based nanocalorimeters have been developed for ac calorimetry experiments. It has allowed highly sensitive measurements of heat capacity from solid state physics to complex systems like polymers and proteins. In this article we…

Large arrays of cryogenic detectors, including transition-edge sensors (TESs) or magnetic micro-calorimeters (MMCs), are needed for future experiments across a wide range of applications. Complexities in integration and cryogenic wiring…

Instrumentation and Detectors · Physics 2020-01-10 C. Yu , A. Ames , S. Chaudhuri , C. Dawson , K. D. Irwin , S. E. Kuenstner , D. Li , C. J. Titus

We have previously used an array of cryogenic microcalorimeters with 4 eV energy resolution to measure emission-line profiles and energies of the characteristic L-shell x rays of four elements of the lanthanide series: praseodymium,…

Instrumentation and Detectors · Physics 2022-10-07 J. W. Fowler , L. Miaja-Avila , G. C. O'Neil , J. N. Ullom , H. Whitelock , D. S. Swetz

Direct spectroscopic biosignature characterization (hereafter "biosignature characterization") will be a major focus for future space observatories equipped with coronagraphs or starshades. Our aim in this article is to provide an…

Instrumentation and Methods for Astrophysics · Physics 2016-08-22 Bernard J. Rauscher , Edgar R. Canavan , S. H. Moseley , John E. Sadleir , Thomas Stevenson

We describe here the first experimental realization of a heat interferometer, thermal counterpart of the well-known superconducting quantum interference device (SQUID). These findings demonstrate, on the first place, the existence of…

Superconductivity · Physics 2014-05-09 M. J. Martínez-Pérez , P. Solinas , F. Giazotto

Near-equilibrium thermal detectors operate as classical calorimeters, with energy deposition and internal equilibration times short compared to the thermal time constant of the device. Advances in fabrication techniques, cryogenics, and…

Instrumentation and Detectors · Physics 2015-06-26 Dan McCammon

The aim of the Cryogenic wide-Area Light Detectors with Excellent Resolution (CALDER) project is the development of light detectors with active area of $5\times5$ cm$^2$ and noise energy resolution smaller than 20 eV RMS, implementing…

Thermoelectric devices convert temperature gradients into electrical power and vice versa, thus enabling energy scavenging from waste heat, sensing and cooling. Yet, many of these attractive applications are hindered by the limited…

Materials Science · Physics 2019-02-14 Davide Donadio

We describe an instrument which can be used to analyze complex chemical mixtures at high resolution and high sensitivity. Molecules are collisionally cooled with helium gas at cryogenic temperatures (~ 4-7 K), and subsequently detected…

Instrumentation and Detectors · Physics 2019-05-22 Jessica P. Porterfield , Lincoln Satterthwaite , Sandra Eibenberger , David Patterson , Michael C. McCarthy

Superconducting quantum computers require microwave control lines running from room temperature to the mixing chamber of a dilution refrigerator. Adding more lines without preliminary thermal modeling to make predictions risks overwhelming…

Quantum Physics · Physics 2025-12-16 Naomi Raicu , Tom Hogan , Xian Wu , Mehrnoosh Vahidpour , David Snow , Matthew Hollister , Mark Field

Fast feedback from cryogenic electrical characterization measurements is key for the development of scalable quantum computing technology. At room temperature, high-throughput device testing is accomplished with a probe-based solution,…

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic…

Instrumentation and Methods for Astrophysics · Physics 2025-01-07 Cesiley L. King , Ian Gullet , Adam J. Anderson , Bradford A. Benson , Rick Bihary , Haichen Fan , Johanna M. Nagy , Hogan Nguyen , John E. Ruhl , Sara M. Simon

We investigate rf SQUIDs (Superconducting QUantum Interference Devices), coupled to a resonant input circuit, a readout tank circuit and a preamplifier, by numerically solving the corresponding Langevin equations and optimizing model…

Superconductivity · Physics 2008-03-13 Reinhold Kleiner , Dieter Koelle , John Clarke

The development of cryogenic calorimeters was originally motivated by the fact that very low energy thresholds and excellent energy resolutions can be achieved by these devices. Cryogenic devices are widely used in double beta decay…

High Energy Physics - Experiment · Physics 2011-01-17 Klaus Pretzl

We report the fabrication and characterization of superconducting quantum interference devices (SQUIDs) based on InAs nanowires and vanadium superconducting electrodes. These mesoscopic devices are found to be extremely robust against…

Mesoscale and Nanoscale Physics · Physics 2011-06-06 Panayotis Spathis , Subhajit Biswas , Stefano Roddaro , Lucia Sorba , Francesco Giazotto , Fabio Beltram

Observations of the Cosmic Microwave Background rely on cryogenic instrumentation with cold detectors, readout, and optics providing the low noise performance and instrumental stability required to make more sensitive measurements. It is…

The heat capacity $\mathcal{C}$ of a given probe is a fundamental quantity that determines, among other properties, the maximum precision in temperature estimation. In turn, $\mathcal{C}$ is limited by a quadratic scaling with the number of…