English
Related papers

Related papers: A novel nuclear recoil calibration for liquid nobl…

200 papers

Detection of low-energy nuclear recoil events plays a central role in searches for particle dark matter interactions with atomic matter and studies of coherent neutrino scatters. Precise nuclear recoil calibration data allow the responses…

Instrumentation and Detectors · Physics 2023-11-07 Jingke Xu , P. S. Barbeau , Ziqing Hong

We propose a new technique for the calibration of nuclear recoils in large noble element dual-phase time projection chambers used to search for WIMP dark matter in the local galactic halo. This technique provides an $\textit{in situ}$…

A method for calibration of cryogenic liquid argon detector response to recoils with certain energy -8.2 keV - is proposed. The method utilizes a process of inelastic scattering of monoenergetic neutrons produced by fusion DD neutron…

Instrumentation and Detectors · Physics 2014-07-11 Sergey Polosatkin , Evgeny Grishnyaev , Alexander Dolgov

The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear…

Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used a Yttrium-Beryllium photoneutron source that…

Instrumentation and Detectors · Physics 2026-05-01 XENON Collaboration , E. Aprile , J. Aalbers , K. Abe , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , D. Antón Martin , F. Arneodo , L. Baudis , M. Bazyk , L. Bellagamba , R. Biondi , A. Bismark , K. Boese , A. Brown , G. Bruno , R. Budnik , C. Cai , C. Capelli , J. M. R. Cardoso , A. P. Cimental Chávez , A. P. Colijn , J. Conrad , J. J. Cuenca-García , V. D'Andrea , L. C. Daniel Garcia , M. P. Decowski , A. Deisting , C. Di Donato , P. Di Gangi , S. Diglio , K. Eitel , S. el Morabit , A. Elykov , A. D. Ferella , C. Ferrari , H. Fischer , T. Flehmke , M. Flierman , W. Fulgione , C. Fuselli , P. Gaemers , R. Gaior , M. Galloway , F. Gao , S. Ghosh , R. Giacomobono , R. Glade-Beucke , L. Grandi , J. Grigat , H. Guan , M. Guida , P. Gyorgy , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , Y. Kaminaga , M. Kara , P. Kavrigin , S. Kazama , P. Kharbanda , M. Kobayashi , D. Koke , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , Z. Liang , Y. T. Lin , S. Lindemann , M. Lindner , K. Liu , M. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , T. Luce , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , E. Masson , S. Mastroianni , A. Melchiorre , J. Merz , M. Messina , A. Michael , K. Miuchi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , U. Oberlack , B. Paetsch , Y. Pan , Q. Pellegrini , R. Peres , C. Peters , J. Pienaar , M. Pierre , G. Plante , T. R. Pollmann , L. Principe , J. Qi , J. Qin , D. Ramírez García , M. Rajado , R. Singh , L. Sanchez , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , J. Shi , M. Silva , H. Simgen , C. Szyszka , A. Takeda , Y. Takeuchi , P. L. Tan , D. Thers , F. Toschi , G. Trinchero , C. D. Tunnell , F. Tönnies , K. Valerius , S. Vecchi , S. Vetter , F. I. Villazon Solar , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , C. Wittweg , V. H. S. Wu , Y. Xing , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , M. Zhong

As part of an experimental effort to demonstrate sensitivity in a large-mass detector to the ultra-low energy recoils expected from coherent neutrino-nucleus elastic scattering, we have designed and built a highly monochromatic 24 keV…

Nuclear Experiment · Physics 2008-11-26 P. S. Barbeau , J. I. Collar , P. M. Whaley

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron…

Instrumentation and Detectors · Physics 2022-10-20 C. S. Amarasinghe , R. Coronel , D. Q. Huang , Y. Liu , M. Arthurs , S. Steinfeld , R. Gaitskell , W. Lorenzon

Dark matter detectors require calibrations of their energy scale and efficiency to detect nuclear recoils in the $1-50$ keV range. Most calibrations use neutron scattering and require MCNP or Geant4 simulations of neutron propagation…

Nuclear Experiment · Physics 2014-03-19 Alan E. Robinson

Low-energy nuclear recoils (NRs) are hard to measure because they produce few e$^{-}$/h$^+$ pairs in solids -- i.e. they have low "ionization yield". A silicon detector was exposed to thermal neutrons over 2.5\,live-days, probing NRs down…

Nuclear Experiment · Physics 2022-04-27 A. N. Villano , M. Fritts , N. Mast , S. Brown , P. Cushman , K. Harris , V. Mandic

Neutrinos from supernova (SN) bursts can give rise to detectable number of nuclear recoil (NR) events through the coherent elastic neutrino-nucleus scattering (CE$\nu$NS) process in large scale liquid xenon detectors designed for direct…

High Energy Astrophysical Phenomena · Physics 2022-01-26 Sayan Ghosh , Abhijit Bandyopadhyay , Pijushpani Bhattacharjee , Sovan Chakraborty , Kamales Kar , Satyajit Saha

Direct searches for light dark matter particles (mass $<10$ GeV) are especially challenging because of the low energies transferred in elastic scattering to typical heavy nuclear targets. We investigate the possibility of using liquid…

Instrumentation and Methods for Astrophysics · Physics 2015-06-12 Wei Guo , Daniel N. McKinsey

The emission of $\gamma$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus…

We study the sensitivity of detectors with directional sensitivity to coherent elastic neutrino-nucleus scattering (CE$\nu$NS), and how these detectors complement measurements of the nuclear recoil energy. We consider stopped pion and…

High Energy Physics - Phenomenology · Physics 2020-07-22 M. Abdullah , D. Aristizabal Sierra , Bhaskar Dutta , Louis E. Strigari

The scintillation properties of liquid helium upon the recoil of a low energy helium atom are discussed in the context of the possible use of this medium as a detector of dark matter. It is found that the prompt scintillation yield in the…

Instrumentation and Methods for Astrophysics · Physics 2013-08-28 T. M. Ito , G. M. Seidel

The energy calibration of calorimeters at collider experiments, such as the ones at the CERN Large Hadron Collider, is crucial for achieving the experiments physics objectives. Standard calibration approaches have limitations that become…

An electron accelerator in the 100 MeV range, similar to the one used at BNL's Accelerator test Facility, for example, would have some advantages as a calibration tool for water cerenkov or Liquid Argon neutrino detectors. We describe a…

Instrumentation and Detectors · Physics 2010-04-20 Sebastian White , Vitaly Yakimenko

Bubble chambers using liquid xenon (and liquid argon) have been operated (resp. planned) by the Scintillating Bubble Chamber (SBC) collaboration for GeV-scale dark matter searches and CE$\nu$NS from reactors. This will require a robust…

Instrumentation and Methods for Astrophysics · Physics 2022-01-26 Daniel Durnford , Marie-Cécile Piro

Nuclear reactors represent a promising neutrino source for CE$\nu$NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can…

High Energy Physics - Experiment · Physics 2024-03-19 A. J. Biffl , A. Gevorgian , K. Harris , A. N. Villano
‹ Prev 1 2 3 10 Next ›