Related papers: Sampling and resolution in sparse view photoacoust…
Photoacoustic tomography (PAT) is a newly emerged imaging modality which enables both high optical contrast and acoustic depth of penetration. Reconstructing images of photoacoustic tomography from limited amount of senser data is among one…
Photoacoustic tomography (PAT) is a nonionizing imaging modality capable of acquiring high contrast and resolution images of optical absorption at depths greater than traditional optical imaging techniques. Practical considerations with…
Purpose: Photoacoustic tomography (PAT) is a novel imaging technique that can spatially resolve both morphological and functional tissue properties, such as the vessel topology and tissue oxygenation. While this capacity makes PAT a…
Compressed sensing (CS) is a promising approach to reduce the number of measurements in photoacoustic tomography (PAT) while preserving high spatial resolution. This allows to increase the measurement speed and to reduce system costs.…
The sparse-driven radar imaging can obtain the high-resolution images about target scene with the down-sampled data. However, the huge computational complexity of the classical sparse recovery method for the particular situation seriously…
Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. When the imaging…
In deep tissue photoacoustic imaging the spatial resolution is inherently limited by the acoustic wavelength. Recently, it was demonstrated that it is possible to surpass the acoustic diffraction limit by analyzing fluctuations in a set of…
Photoacoustic imaging (PAI) is a non-invasive imaging modality that detects the ultrasound signal generated from tissue with light excitation. Photoacoustic computed tomography (PACT) uses unfocused large-area light to illuminate the target…
A crucial limitation of current high-resolution 3D photoacoustic tomography (PAT) devices that employ sequential scanning is their long acquisition time. In previous work, we demonstrated how to use compressed sensing techniques to improve…
Photoacoustic tomography (PAT) enables non-invasive cross-sectional imaging of biological tissues, but it fails to map the spatial variation of speed-of-sound (SOS) within tissues. While SOS is intimately linked to density and elastic…
Applying standard algorithms to sparse data problems in photoacoustic tomography (PAT) yields low-quality images containing severe under-sampling artifacts. To some extent, these artifacts can be reduced by iterative image reconstruction…
Existing approaches to image reconstruction in photoacoustic computed tomography (PACT) with acoustically heterogeneous media are limited to weakly varying media, are computationally burdensome, and/or cannot effectively mitigate the…
The ability to resolve detail in the object that is being imaged, named by resolution, is the core parameter of an imaging system. Super-resolution is a class of techniques that can enhance the resolution of an imaging system and even…
Photoacoustic tomography (PAT) is a novel and rapidly promising technique in the field of medical imaging, based on the generation of acoustic waves inside an object of interest by stimulating non-ionizing laser pulses. This acoustic wave…
In this article, we study several reconstruction methods for the inverse source problem of photoacoustic tomography (PAT) with spatially variable sound speed and damping. The backbone of these methods is the adjoint operators, which we…
We address the problem of image reconstruction from incomplete measurements, encompassing both upsampling and inpainting, within a learning-based framework. Conventional supervised approaches require fully sampled ground truth data, while…
This paper investigates photoacoustic tomography with two spatially varying acoustic parameters, the compressibility and the density. We consider the reconstruction of the absorption density parameter (imaging parameter of Photoacoustics)…
Standard photoacoustic tomography (PAT) provides data that consist of time-dependent signals governed by the wave equation, which are measured on an observation surface. In contrast, the measured data from the recently invented full-field…
It has previously been demonstrated that model-based reconstruction methods relying on a priori knowledge of the imaging point spread function (PSF) coupled to sparsity priors on the object to image can provide super-resolution in…
Photoacoustic tomography (PAT) is a hybrid medical imaging technique that offer high contrast and a high spatial resolution. One challenging mathematical problem associated with PAT is reconstructing the initial pressure of the wave…