Related papers: Simulating the secondary electron avalanche of MCP…
We report on an apparatus able to measure the absolute detection efficiency of a detector for electrons in the 30 - 900 eV range. In particular, we discuss the characterisation of a two-stage chevron microchannel plate (MCP). The…
With their fast response time and a spatial resolution in the range of a few microns, microchannel plates (MCPs) are a prominent choice for the development of detectors with highest resolution standards. Amorphous silicon-based microchannel…
Microchannel plates (MCPs) were recently proposed as novel type of cathodes for electron guns, suitable for applications in design of electron lenses. We report results of the first systematic study of microchannel plate based…
Hundreds of concurrent collisions per bunch crossing are expected at future hadron colliders. Precision timing calorimetry has been advocated as a way to mitigate the pileup effects and, thanks to their excellent time resolution,…
One of the on-going issues with the use of microchannel plates (MCP) in the ionization profile monitors (IPM) at Fermilab is the significant decrease in gain over time. There are several possible issues that can cause this. Historically,…
We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP surface has long been proposed and is used…
The atomic layer deposition(ALD) coating lengthens the lifetime of microchannel plates(MCP), which are used as the electron amplifier of the photomultiplier tubes(PMT). In the Jinping Neutrino Experiment, the newly developed 8-inch MCP-PMT…
This paper presents a technique to measure the gain of a single-plate micro-channel plate (MCP)/phosphor assembly by using a convolutional neural network to analyse images of the phosphor screen, recorded by a charge coupled device. The…
Microchannel plates (MCP) are the basis for many spatially-resolved single-particle detectors such as ICCD or I-sCMOS cameras employing image intensifiers (II), MCPs with delay-line anodes for the detection of cold gas particles or…
The motivation of this paper is to explore the parameters that affect the performance of Microchannel Plate Photomultiplier Tubes (MCP-PMTs) in magnetic fields with the goal to guide their design to achieve a high magnetic field tolerance.…
Micro-channel plate (MCP) detectors, when used at pulsed-neutron-source instruments, offer the possibility of high spatial resolution and high contrast imaging with pixel-level spectroscopic information. Here we demonstrate the possibility…
A new kind of dual-band reflection-mode circular polarizers (RMCPs) is introduced with wide bandwidth and wide-view at the operating frequencies. The proposed RMCPs are based on dual-layer rectangular patches on both sides of a substrate,…
We have designed and tested a robust 20 $\times$ 20 cm$^2$ thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in…
We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…
Millimeter-wave (mmWave) bands will be used for the fifth generation communication systems to support high data rates. For the proper characterization of the mmWave propagation channel, it is essential to measure the power angular-delay…
Multi Micro-Channel-Plate Photomultiplier tubes (MCP-PMT) with High Collection Efficiency (Hi-CE) MCPs are developed and characterised. With these Hi-CE MCPs more than 90% of photoelectrons emitted from the photocathode can be detected;…
An advanced technique for a two-dimensional real time visualization of cluster beams in vacuum as well as of the overlap volume of cluster beams with particle accelerator beams is presented. The detection system consists of an array of…
In order to test the $^{16}$C internal wave function, we perform microscopic coupled-channels (MCC) calculations of the $^{16}$C($0_1^+ \to 2_1^+$) inelastic scattering by $^{208}$Pb target at $E/A$=52.7 MeV using the antisymmetrized…
We present an experimental demonstration of the efficient acceleration of electrons beyond 60 MeV using micro-channel plasma targets. We employed a high-contrast, 2.5 J, 32 fs short pulse laser interacting with a 5 \mu m inner diameter, 300…
A systematic investigation of Planacon MCP-PMTs was performed using 64 XP85002/FIT-Q photosensors. These devices are equipped with microchannel plates of reduced resistance. Results of a study of their gain stability over time and…