English
Related papers

Related papers: The Optimal use of Segmentation for Sampling Calor…

200 papers

Calorimeter-assisted track finding algorithm takes advantage of the finely segmented electromagnetic calorimeter proposed for the SiD detector concept by looking for "MIP stubs" produced by charged particles in the calorimeter, and using…

Instrumentation and Detectors · Physics 2009-02-16 Dmitry Onoprienko , Eckhard von Toerne

Fine-grained power estimation in multicore Systems on Chips (SoCs) is crucial for efficient thermal management. BPI (Blind Power Identification) is a recent approach that determines the power consumption of different cores and the thermal…

Performance · Computer Science 2024-10-29 Mohamed R. Elshamy , Mehdi Elahi , Ahmad Patooghy , Abdel-Hameed A. Badawy

Beams of Carbon nuclei are used or planned to be used in various centers for cancer treatment around the world because of their therapeutic advantages over proton beams. The knowledge of the fragmentation of Carbon nuclei when they interact…

Simulating showers of particles in highly-granular calorimeters is a key frontier in the application of machine learning to particle physics. Achieving high accuracy and speed with generative machine learning models can enable them to…

Instrumentation and Detectors · Physics 2026-02-02 Thorsten Buss , Frank Gaede , Gregor Kasieczka , Anatolii Korol , Katja Krüger , Peter McKeown , Martina Mozzanica

The precise measurement of hadronic jet energy is crucial to maximise the physics reach of a future Linear Collider. An important ingredient required to achieve this is the efficient identification of photons within hadronic showers. One…

Instrumentation and Detectors · Physics 2015-06-04 Daniel Jeans , Jean-Claude Brient , Marcel Reinhard

Studying the growth and metabolism of microbes provides critical insights into their evolutionary adaptations to harsh environments, which are essential for microbial research and biotechnology applications. In this study, we developed an…

Image and Video Processing · Electrical Eng. & Systems 2025-05-06 Shuang Zhang , Carleton Coffin , Karyn L. Rogers , Catherine Ann Royer , Ge Wang

We present a novel topography scanning system developed to XLPE cable core monitoring. Modern measurement technology is utilized together with embedded high-performance computing to build a complete and detailed 3D surface map of the…

Machine Learning · Computer Science 2026-02-09 Janne Harjuhahto , Jaakko Harjuhahto , Mikko Lahti , Jussi Hanhirova , Björn Sonerud

The estimation of differential energy loss for charged particles in tracker detectors is studied. The robust truncated mean method can be generalized to the linear combination of the energy deposit measurements. The optimized weights in…

Data Analysis, Statistics and Probability · Physics 2012-07-02 Ferenc Sikler , Sandor Szeles

Coherent diffractive imaging (CDI) is widely used to characterize structured samples from measurements of diffracting intensity patterns. We introduce a numerical framework to quantify the precision that can be achieved when estimating any…

Optics · Physics 2021-01-08 Dorian Bouchet , Jacob Seifert , Allard P. Mosk

Calorimeters for particle physics experiments with integration time of a few ns will substantially improve the capability of the experiment to resolve event pileup and to reject backgrounds. In this paper the time development of hadronic…

Instrumentation and Detectors · Physics 2018-05-24 Dmitri Denisov , Strahinja Lukić , Nikolai Mokhov , Sergei Striganov , Predrag Ujić

CMS calorimeter energy calibration was done in the full CMS simulated geometry for the pseudorapidity region eta = 0. The samples of single pion events were generated with a set of incident energies from 5 GeV to 3 TeV and for single…

High Energy Physics - Experiment · Physics 2007-05-23 J. Damgov , V. Genchev , S. Cht. Mavrodiev

A new method called Neighbor Cell Deposited Energy Ratio (NCDER) is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL).This method was applied to reconstruct the ECAL…

Instrumentation and Detectors · Physics 2015-06-17 Zu-Hao Li , Wei-Wei Xu , Ling-Yu Wang , Cheng Zhang , Zhi-Cheng Tang , Qi Yan , Min Yang , Yu-Sheng Lu , Guo-Ming Chen , He-Sheng Chen

Power management is an expensive and important issue for large computational infrastructures such as datacenters, large clusters, and computational grids. However, measuring energy consumption of scalable systems may be impractical due to…

Machine Learning · Computer Science 2017-09-20 Lucas Venezian Povoa , Cesar Marcondes , Hermes Senger

SiD is a robust, silicon-based detector proposed for the International Linear Collider (ILC). SiD employs a sampling silicon-tungsten electromagnetic calorimeter (ECal) to accurately measure the energies of electrons, positrons, and photons…

Instrumentation and Detectors · Physics 2020-02-17 Lucas Braun , Jason T. Barkeloo , James E. Brau , Christopher T. Potter

In this paper, we discuss the way advanced machine learning techniques allow physicists to perform in-depth studies of the realistic operating modes of the detectors during the stage of their design. Proposed approach can be applied to both…

Instrumentation and Detectors · Physics 2021-02-03 F. Ratnikov , D. Derkach , A. Boldyrev , A. Shevelev , P. Fakanov , L. Matyushin

The granularity of calorimeter has been revolutionary boosted for future collider experiments. The calorimeter has been pushed to a stage that the sub structure of showers especially hadronic showers can be recorded to a high precision. New…

Instrumentation and Detectors · Physics 2014-12-11 Manqi Ruan

Sufficient energy resolution is the key issue for the calorimetry in particle and nuclear physics. The calorimeter of the A4 parity violation experiment at MAMI is a segmented calorimeter where the energy of an event is determined by…

An innovative and accurate dynamic Compact Thermal Model extraction method is proposed for multi-chip power electronics systems. It accounts for thermal coupling between multiple heat sources. Transient electro-thermal coupling can easily…

General Physics · Physics 2008-01-08 W. Habra , P. Tounsi , F. Madrid , P. Dupuy , C. Barbot , J. -M. Dorkel