Related papers: Improving Axial Resolution of Optical Resolution P…
In Photoacoustic imaging (PAI), the most prevalent beamforming algorithm is delay-and-sum (DAS) due to its simple implementation. However, it results in a low quality image affected by the high level of sidelobes. Coherence factor (CF) can…
Astronomical telescopes suffer from a tradeoff between field of view (FoV) and image resolution: increasing the FoV leads to an optical field that is under-sampled by the science camera. This work presents a novel computational imaging…
In Photoacoustic imaging, Delay-and-Sum (DAS) algorithm is the most commonly used beamformer. However, it leads to a low resolution and high level of sidelobes. Delay-Multiply-and-Sum (DMAS) was introduced to provide lower sidelobes…
Photoacoustic Microscopy (PAM) images integrating the advantages of optical contrast and acoustic resolution have been widely used in brain studies. However, there exists a trade-off between scanning speed and image resolution. Compared…
Delay and sum (DAS) is the most common beamforming algorithm in linear-array photoacoustic imaging (PAI) as a result of its simple implementation. However, it leads to a low resolution and high sidelobes. Delay multiply and sum (DMAS) was…
Optically pumped magnetometers (OPMs) have emerged as a powerful technique for high-resolution magnetic field imaging. However, achieving sub-millimeter spatial resolution at sub-picotesla sensitivities ($\mathrm{< 1\,pT/\sqrt{Hz}}$)…
Photoacoustic image (PAI) quality improvement using a low frequency piezoelectric micromachined ultrasound transducer (PMUT) having the fundamental resonant frequency 1 MHz is being reported. Specifically, three different methods are…
Ultrasound imaging, despite its widespread use in medicine, often suffers from various sources of noise and artifacts that impact the signal-to-noise ratio and overall image quality. Enhancing ultrasound images requires a delicate balance…
Delay-and-Sum (DAS) beamformer is the most common beamforming algorithm in Photoacoustic imaging (PAI) due to its simple implementation and real time imaging. However, it provides poor resolution and high levels of sidelobe. A new algorithm…
Three-photon (3-P) fluorescence microscopy enables deep in vivo imaging with subcellular resolution, but its performance is fundamentally constrained by the maximum permissible laser power required to avoid tissue heating and photodamage.…
Although signal distortion-based peak-to-average power ratio (PAPR) reduction is a feasible candidate for orthogonal frequency division multiplexing (OFDM) to meet standard/regulatory requirements, the error vector magnitude (EVM) stemming…
Atmospheric turbulence characterization is crucial for technologies like free-space optical communications. Existing methods using a spatially-integrated one-dimensional (1D) orbital angular momentum (OAM) spectrum, P(m), obscure the…
Wide-field fluorescence microscopy, while much faster than confocal microscopy, suffers from a lack of optical sectioning and poor axial resolution. 3D structured illumination microscopy (SIM) has been demonstrated to provide optical…
Current optoacoustic microscopy configurations often have narrow focal ranges that limit their use for fast volumetric imaging applications. Here, the focal range of optoacoustic microscopes is extended by matching the elongated optical…
Linear-array based photoacoustic images are reconstructed using the conventional delay-and-sum (DAS) beamforming method. Although the DAS beamformer is well suited for PA image formation, reconstructed images are often afflicted by noises,…
Photoacoustic imaging (PAI) is an emerging medical imaging modality capable of providing high spatial resolution of Ultrasound (US) imaging and high contrast of optical imaging. Delay-and-Sum (DAS) is the most common beamforming algorithm…
Optical tomographic reconstruction of a 3D nanoscale specimen is hindered by the axial diffraction limit, which is 2-3 times worse than the focal plane resolution. We propose and experimentally demonstrate an axial super-resolution…
Anisotropic Diffusion is widely used for noise reduction with simultaneous preservation of vascular structures in maximum intensity projected (MIP) angiograms. However, extension to minimum intensity projected (mIP) venograms in…
The effect of noise on the Inverse Synthetic Aperture Radar (ISAR) with sparse apertures is a challenging issue for image reconstruction with high resolution at low Signal-to-Noise Ratios (SNRs). It is well-known that the image resolution…
The resolution of photoacoustic imaging deep inside scattering media is limited by the acoustic diffraction limit. In this work, taking inspiration from super-resolution imaging techniques developed to beat the optical diffraction limit, we…