English
Related papers

Related papers: Why would you put a flashlight in a dark matter de…

200 papers

In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…

Silicon Photomultipliers (SiPMs) are photon-counting detectors with great potential to improve the sensitivity of optical receivers. Recent studies of SiPMs in communication focus on the speed rather than the power consumption of the…

Signal Processing · Electrical Eng. & Systems 2024-04-05 Yangchun Li , Danial Chitnis

The light yield, the time resolution and the efficiency of different types of scintillating tiles with direct Silicon Photomultiplier readout and instrumented with a customised front-end electronics have been measured at the Beam Test…

The motivation of the current R&D project is based upon the requirements of the JEDI international collaboration aiming to measure Electric Dipole Moments (EDMs) of charged particles in storage rings. One of the most important elements of…

A mini-PET style detector system is being developed for a plant imaging application with a compact array of silicon photomultipliers (SiPM) replacing position sensitive photomultipliers (PSPMT). In addition to compactness, the use of SiPMs…

Dark matter plays a crucial role in our comprehension of the universe, but its mysterious nature poses challenges for direct detection. A primary obstacle in detecting dark matter is distinguishing genuine signals from the prevailing…

High Energy Physics - Experiment · Physics 2025-03-05 M. Mirzakhani , S. Maludze

The search for dark matter is one of today's most exciting fields. As bigger detectors are being built to increase their sensitivity, background reduction is an ever more challenging issue. To this end, a new type of dark matter detector is…

Instrumentation and Methods for Astrophysics · Physics 2016-03-11 C. Levy , S. Fallon , J. Genovesi , D. Khaitan , K. Klimov , J. Mock , M. Szydagis

We are developing a novel high-brightness atomic beam, comprised of a two-body exotic atom called muonium (M $ = \mu^+ + e^-$), for next-generation atomic physics and gravitational interaction measurements. This M source originates from a…

Instrumentation and Detectors · Physics 2022-06-29 J. Zhang , D. Goeldi , R. Iwai , M. Sakurai , A. Soter

Next generation multi-ton scale noble liquid experiments have the unique opportunity to discover dark matter particles at the TeV scale, reaching the sensitivity of 10^-48 cm2 in the WIMP nucleon scattering cross-section. A prerequisite…

Instrumentation and Detectors · Physics 2016-01-07 S. Catalanotti , A. G. Cocco , G. Covone , M. D Incecco , G. Fiorillo , G. Korga , B. Rossi , S. Walker

Silicon photomultipliers (SiPMs) have become the baseline choice for cameras of the small-sized telescopes (SSTs) of the Cherenkov Telescope Array (CTA). On the other hand, SiPMs are relatively new to the field and covering large surfaces…

Silicon Photo-multipliers (SiPMs) are very sensitive photo-detectors that experienced a big development in the last years in several applications, like LIDAR, astrophysics, medical imaging and high energy physics (HEP) experiments. In HEP…

Instrumentation and Detectors · Physics 2021-12-16 Anna Rita Altamura , Fabio Acerbi , Benedetto Di Ruzza , Enrico Verroi , Stefano Merzi , Alberto Gola

The search for light dark matter and cosmic primordial neutrinos necessitates detectors with sub-millielectronvolt (sub-meV) energy thresholds. While superconducting quantum sensors have approached this sensitivity, they often face…

Instrumentation and Detectors · Physics 2026-02-05 Aiqin Gao , Yiming Guo , Hengyu Wang , Xilei Sun , Xuegang Li , Junhua Wang , Junguang Lv , Guopu Qu , Lei Cao

Optical parametric down-conversion (PDC) is a central tool in quantum optics experiments. The number of collected down-converted modes greatly affects the quality of the produced photon state. We use Silicon Photomultiplier (SiPM)…

Quantum Physics · Physics 2015-06-03 L. Dovrat , M. Bakstein , D. Istrati , A. Shaham , H. S. Eisenberg

A Python program has been developed which fits a published detector-response model to SiPM charge spectra to characterise SiPMs. Spectra for SiPMs illuminated by low intensity pulsed light with Poisson-distributed number of photons and a…

Instrumentation and Detectors · Physics 2023-01-30 Jack Rolph , Erika Garutti , Robert Klanner , Tobias Quadfasel , Joern Schwandt

Reflectance of silicon photomultipliers (SiPMs) is an important aspect to understand the large scale SiPM-based detector systems and evaluate the performance of SiPMs. We report the reflactance of two SiPMs, NUV-HD-lowCT and S14160-60-50HS…

Instrumentation and Detectors · Physics 2020-06-24 W. Wang , G. F. Cao , Z. Q. Xie , J. Cao , M. Qi , L. J. Wen

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and…

High Energy Physics - Experiment · Physics 2024-08-19 T. Contreras , B. Palmeiro , H. Almazán , A. Para , G. Martínez-Lema , R. Guenette , C. Adams , V. Álvarez , B. Aparicio , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , C. D. R. Azevedo , K. Bailey , F. Ballester , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodolin , N. Byrnes , S. Cárcel , A. Castillo , S. Cebrián , E. Church , L. Cid , C. A. N. Conde , F. P. Cossío , E. Dey , G. Díaz , T. Dickel , C. Echevarria , M. Elorza , J. Escada , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , A. L. Ferreira , F. W. Foss , Z. Freixa , J. García-Barrena , J. J. Gómez-Cadenas , R. González , J. W. R. Grocott , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , P. Lebrun , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. P. Marques , J. Martín-Albo , M. Martínez-Vara , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , P. Novella , A. Nuñez , D. R. Nygren , E. Oblak , J. Palacio , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Pérez Maneiro , M. Querol , A. B. Redwine , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , J. Torrent , A. Trettin , A. Usón , P. R. G. Valle , J. F. C. A. Veloso , J. Waiton , A. Yubero-Navarro

Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…

A systematic study of the nonlinear response of Silicon Photomultipliers (SiPMs) has been conducted through Monte Carlo simulations. SiPMs have been proven to show a universal nonlinear response when it is expressed in terms of relative…

Instrumentation and Detectors · Physics 2024-01-15 Victor Moya , Jaime Rosado

Optical crosstalk seriously limits the photon-counting resolution of silicon photomultipliers. In this work, realistic analytical models to describe the crosstalk effects on the response of these photodetectors are presented and compared…

Instrumentation and Detectors · Physics 2015-06-12 L. Gallego , J. Rosado , F. Blanco , F. Arqueros

We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX…

Cosmology and Nongalactic Astrophysics · Physics 2020-02-19 D. S. Akerib , S. Alsum , H. M. Araújo , X. Bai , A. J. Bailey , J. Balajthy , A. Baxter , P. Beltrame , E. P. Bernard , A. Bernstein , T. P. Biesiadzinski , E. M. Boulton , B. Boxer , P. Brás , S. Burdin , D. Byram , S. B. Cahn , M. C. Carmona-Benitez , C. Chan , A. A. Chiller , C. Chiller , A. Currie , J. E. Cutter , L. de Viveiros , A. Dobi , J. E. Y. Dobson , E. Druszkiewicz , B. N. Edwards , C. H. Faham , S. R. Fallon , A. Fan , S. Fiorucci , R. J. Gaitskell , V. M. Gehman , J. Genovesi , C. Ghag , K. R. Gibson , M. G. D. Gilchriese , E. Grace , C. Gwilliam , C. R. Hall , M. Hanhardt , S. J. Haselschwardt , S. A. Hertel , D. P. Hogan , M. Horn , D. Q. Huang , C. M. Ignarra , R. G. Jacobsen , O. Jahangir , W. Ji , K. Kamdin , K. Kazka , D. Khaitan , R. Knoche , E. V. Korolkova , S. Kravitz , V. A. Kudryavtsev , N. A. Larsen , E. Leason , C. Lee , B. G. Lenardo , K. T. Lesko , C. Levy , J. Liao , J. Lin , A. Lindote , M. I. Lopes , B. López-Paredes , A. Manalaysay , R. L. Mannino , N. Marangou , M. F. Marzioni , D. N. McKinsey , D. M. Mei , J. Mock , M. Moongweluwan , J. A. Morad , A. St. J. Murphy , A. Naylor , C. Nehrkorn , H. N. Nelson , F. Neves , A. Nilima , K. O'Sullivan , K. C. Oliver-Mallory , K. J. Palladino , E. K. Pease , L. Reichhart , Q. Riffard , G. R. C. Rischbieter , P. Rossiter , S. Shaw , T. A. Shutt , C. Silva , M. Solmaz , V. N. Solovov , P. Sorensen , S. Stephenson , T. J. Sumner , M. Szydagis , D. J. Taylor , R. Taylor , W. C. Taylor , B. P. Tennyson , P. A. Terman , D. R. Tiedt , W. H. To , M. Tripathi , L. Tvrznikova , U. Utku , S. Uvarov , A. Vacheret , V. Velan , J. R. Verbus , R. C. Webb , J. T. White , T. J. Whitis , M. S. Witherell , F. L. H. Wolfs , D. Woodward , J. Xu , K. Yazdani , S. K. Young , C. Zhang
‹ Prev 1 4 5 6 7 8 10 Next ›