English
Related papers

Related papers: Transient analysis of arm locking controller

200 papers

We present a compact laser frequency stabilization method by locking a 556 nm laser to a high-precision wavelength meter. Unlike traditional schemes that rely on optical cavities or atomic references, we stabilize the laser frequency via a…

Optics · Physics 2025-06-27 Mengde Gan , Haoyi Zhang , Xiaodong Tan , Jiaming Li , Le Luo

Equal-arm interferometric detectors of gravitational radiation allow phase measurements many orders of magnitude below the intrinsic phase stability of the laser injecting light into their arms. This is because the noise in the laser light…

General Relativity and Quantum Cosmology · Physics 2021-03-25 Massimo Tinto , Sanjeev V. Dhurandhar

Unlike ground-based interferometric gravitational wave detectors, large space-based systems will not be rigid structures. When the end-stations of the laser interferometer are freely flying spacecraft, the armlengths will change due to…

General Relativity and Quantum Cosmology · Physics 2009-11-07 Shane L. Larson , Ronald W. Hellings , William A. Hiscock

A ring laser is defined by its perimeter, which directly enters the conversion factor between measured Sagnac frequency and the actual rotation rate. Large ring lasers employed in geodesy and fundamental physics require stability of the…

Optics · Physics 2026-03-13 Jannik Zenner , Karl Ulrich Schreiber , Simon Stellmer

Low frequency high precision laser interferometry is subject to excess laser-frequency-noise coupling via arm-length differences which is commonly mitigated by locking the frequency to a stable reference system. This approach is crucial to…

Instrumentation and Detectors · Physics 2017-03-01 Oliver Gerberding , Katharina-Sophie Isleif , Moritz Mehmet , Karsten Danzmann , Gerhard Heinzel

Interferometric gravitational-wave detectors like LIGO need to be able to measure changes in their arm lengths of order $10^{-18}~$m or smaller. This requires very high laser power in order to raise the signal above shot noise. One…

Applied Physics · Physics 2019-12-11 S. Biscans , S. Gras , C. D. Blair , J. Driggers , M. Evans , P. Fritschel , T. Hardwick , G. Mansell

To meet the strain sensitivity requirements [1], [2] of the Laser Interferometer Gravitational Wave Observatory (LIGO), the laser frequency and amplitude noise must initially be reduced by a factor of 1000 in the pre-stabilized portion of…

Instrumentation and Detectors · Physics 2007-05-23 R. Abbott , P. King

The high tech industry which requires fast stable motion with nanometer precision continues to mainly use PID which is limited by fundamental linear control limitations. Floor vibrations as disturbance significantly affect performance and…

Systems and Control · Electrical Eng. & Systems 2020-05-06 Erdi Akyüz , Niranjan Saikumar , S. Hassan HosseinNia

In contact-rich tasks, setting the stiffness of the control system is a critical factor in its performance. Although the setting range can be extended by making the stiffness matrix asymmetric, its stability has not been proven. This study…

Robotics · Computer Science 2026-03-19 Toshiaki Tsuji , Yasuhiro Kato

Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock…

Instrumentation and Detectors · Physics 2020-01-15 T. Akutsu , M. Ando , K. Arai , K. Arai , Y. Arai , S. Araki , A. Araya , N. Aritomi , Y. Aso , S. Bae , Y. Bae , L. Baiotti , R. Bajpai , M. A. Barton , K. Cannon , E. Capocasa , M. Chan , C. Chen , K. Chen , Y. Chen , H. Chu , Y-K. Chu , K. Doi , S. Eguchi , Y. Enomoto , R. Flaminio , Y. Fujii , M. Fukunaga , M. Fukushima , G. Ge , A. Hagiwara , S. Haino , K. Hasegawa , H. Hayakawa , K. Hayama , Y. Himemoto , Y. Hiranuma , N. Hirata , E. Hirose , Z. Hong , B. H. Hsieh , G-Z. Huang , P. Huang , Y. Huang , B. Ikenoue , S. Imam , K. Inayoshi , Y. Inoue , K. Ioka , Y. Itoh , K. Izumi , K. Jung , P. Jung , T. Kajita , M. Kamiizumi , S. Kanbara , N. Kanda , G. Kang , K. Kawaguchi , N. Kawai , T. Kawasaki , C. Kim , J. C. Kim , W. S. Kim , Y. -M. Kim , N. Kimura , N. Kita , H. Kitazawa , Y. Kojima , K. Kokeyama , K. Komori , A. K. H. Kong , K. Kotake , C. Kozakai , R. Kozu , R. Kumar , J. Kume , C. Kuo , H-S. Kuo , S. Kuroyanagi , K. Kusayanagi , K. Kwak , H. K. Lee , H. W. Lee , R. Lee , M. Leonardi , L. C. -C. Lin , C-Y. Lin , F-L. Lin , G. C. Liu , L. -W. Luo , M. Marchio , Y. Michimura , N. Mio , O. Miyakawa , A. Miyamoto , Y. Miyazaki , K. Miyo , S. Miyoki , S. Morisaki , Y. Moriwaki , M. Musha , K. Nagano , S. Nagano , K. Nakamura , H. Nakano , M. Nakano , R. Nakashima , T. Narikawa , R. Negishi , W. -T. Ni , A. Nishizawa , Y. Obuchi , W. Ogaki , J. J. Oh , S. H. Oh , M. Ohashi , N. Ohishi , M. Ohkawa , N. Ohmae , K. Okutomi , K. Oohara , C. P. Ooi , S. Oshino , K. Pan , H. Pang , J. Park , F. E. Peña Arellano , I. Pinto , N. Sago , S. Saito , Y. Saito , K. Sakai , Y. Sakai , Y. Sakuno , S. Sato , T. Sato , T. Sawada , T. Sekiguchi , Y. Sekiguchi , S. Shibagaki , R. Shimizu , T. Shimoda , K. Shimode , H. Shinkai , T. Shishido , A. Shoda , K. Somiya , E. J. Son , H. Sotani , R. Sugimoto , T. Suzuki , T. Suzuki , H. Tagoshi , H. Takahashi , R. Takahashi , A. Takamori , S. Takano , H. Takeda , M. Takeda , H. Tanaka , K. Tanaka , K. Tanaka , T. Tanaka , T. Tanaka , S. Tanioka , E. N. Tapia San Martin , D. Tatsumi , S. Telada , T. Tomaru , Y. Tomigami , T. Tomura , F. Travasso , L. Trozzo , T. Tsang , K. Tsubono , S. Tsuchida , T. Tsuzuki , D. Tuyenbayev , N. Uchikata , T. Uchiyama , A. Ueda , T. Uehara , K. Ueno , G. Ueshima , F. Uraguchi , T. Ushiba , M. H. P. M. van Putten , H. Vocca , J. Wang , C. Wu , H. Wu , S. Wu , W-R. Xu , T. Yamada , K. Yamamoto , K. Yamamoto , T. Yamamoto , K. Yokogawa , J. Yokoyama , T. Yokozawa , T. Yoshioka , H. Yuzurihara , S. Zeidler , Y. Zhao , Z. -H. Zhu

Ground-based laser interferometric gravitational wave detectors consist of complex multiple optical cavity systems. An arm-length stabilization (ALS) system has played an important role in bringing such complex detector into operational…

Optics · Physics 2024-10-08 Satoshi Tanioka , Bin Wu , Stefan W. Ballmer

Time-resolved atom interferometry, as employed in applications such as gravitational wave detection and searches for ultra-light dark matter, requires precise control over systematic effects. In this work, we investigate phase noise arising…

Atomic Physics · Physics 2025-11-25 Noam Mouelle , Jeremiah Mitchell , Valerie Gibson , Ulrich Schneider

A key action for enhancing the sensitivity of gravitational wave (GW) detectors based on laser interferometry is to increase the laser power. However, in such a high-power regime, a nonlinear optomechanical phenomenon called parametric…

Instrumentation and Methods for Astrophysics · Physics 2019-10-16 Margherita Turconi , Thomas Harder , Rémi Soulard , Walid Chaibi

Technical noise present in laser systems can limit their ability to perform high fidelity quantum control of atomic qubits. The ultimate fidelity floor for atomic qubits driven with laser radiation is due to spontaneous emission from…

Quantum Physics · Physics 2021-12-10 Matthew L Day , Pei Jiang Low , Brendan M White , Rajibul Islam , Crystal Senko

We demonstrate a high-stability laser offset-frequency locking technique based on a balanced filter discriminator. The beat note between two 852 nm external-cavity diode lasers is down-converted in two parallel arms using local-oscillator…

We demonstrate a compact and robust device for simultaneous absolute frequency stabilization of three diode lasers whose carrier frequencies can be chosen freely relative to the reference. A rigid ULE multi-cavity block is employed, and,…

Broad-area semiconductor lasers are employed in many high-power applications, however, their spatio-temporal dynamics is complex and intrinsically unstable due to the interaction of several transverse lasing modes. A dynamical and…

Optics · Physics 2025-07-17 S. Bittner , M. Sciamanna

Optical lattices formed by interfering laser beams are widely used to trap and manipulate atoms for quantum simulation, metrology, and computation. To stabilize optical lattices in experiments, it is usually challenging to implement…

Quantum Physics · Physics 2026-04-14 Yirong Wang , Xiaoyu Dai , Xue Zhao , Guangren Sun , Kuiyi Gao , Wei Zhang

The PID controller remains the most widely adopted control architecture, with groundbreaking success across extensive implications. However, optimal parameter tuning for PID controller remains a critical challenge. Existing theories…

Systems and Control · Electrical Eng. & Systems 2025-07-17 Zimao Sheng , Hongan Yang , Jiakang Wang , Tong Zhang

Phase-locked loops are commonly used for shaker-based backbone tracking of nonlinear structures. The state of the art is to tune the control parameters by trial and error. In the present work, an approach is proposed to make backbone…

Systems and Control · Electrical Eng. & Systems 2024-07-02 Patrick Hippold , Maren Scheel , Ludovic Renson , Malte Krack