In this paper, we study the placement of Phasor Measurement Units (PMU) for enhancing hybrid state estimation via the traditional Gauss-Newton method, which uses measurements from both PMU devices and Supervisory Control and Data…

Optimization and Control · Mathematics 2016-11-15 Xiao Li , Anna Scaglione , Tsung-Hui Chang

In this paper, phasor measurement unit (PMU) placement for power grid state estimation under different degrees of observability is studied. Observability degree is the depth of the buses' reachability by the placed PMUs and thus constitutes…

Systems and Control · Computer Science 2018-06-08 Y. Shi , H. D. Tuan , A. A. Nasir , T. Q. Duong , H. V. Poor

This paper presents an innovative approach to micro-phasor measurement unit (micro-PMU) placement in unbalanced distribution networks. The methodology accounts for the presence of single-and-two-phase laterals and acknowledges the fact that…

Systems and Control · Electrical Eng. & Systems 2020-08-04 Reetam Sen Biswas , Behrouz Azimian , Anamitra Pal

Phasor measurement units (PMUs) are important devices for protection, monitoring, and control of modern power systems. Unlike the supervisory control and data acquisition (SCADA) system which only measure the magnitude, PMUs can provide a…

Systems and Control · Electrical Eng. & Systems 2021-05-06 Lorena Palmero , Ugur Saritac , Ali Dehghan Chaharabi

Phasor measurement units (PMUs) provide accurate and high-fidelity measurements in order to monitor the state of the power grid and support various control and planning tasks. However, PMUs have a high installation cost prohibiting their…

Systems and Control · Electrical Eng. & Systems 2023-04-18 Saptarshi Ghosh , Murali Sankar Venkatraman , Shehab Ahmed , Charalambos Konstantinou

Phasor Measurement Units (PMUs) are essential measuring devices for monitoring, control and protection of power systems. The objective of the optimal PMU placement (OPP) problem is to minimize the number of PMUs and select the bus locations…

Optimization and Control · Mathematics 2015-08-25 Nikolaos Theodorakatos , Nikolaos Manousakis , George Korres

The most commonly used weighted least square state estimator in power industry is nonlinear and formulated by using conventional measurements such as line flow and injection measurements. PMUs (Phasor Measurement Units) are gradually adding…

Systems and Control · Computer Science 2017-03-22 Hossein A. Sangrody , Mohammad Taghi Ameli

The phasor measurement unit (PMU) placement problem is revisited by taking into account a stronger characterization of the electrical connectedness between various buses in the grid. To facilitate this study, the placement problem is…

Systems and Control · Computer Science 2015-05-19 K. G. Nagananda , Shalinee Kishore , Rick S. Blum

The lack of measurements in distribution grids poses a severe challenge for their monitoring: since there may not be enough sensors to achieve numerical observability, load forecasts (pseudo-measurements) are typically used, and thus an…

Systems and Control · Electrical Eng. & Systems 2019-08-09 Miguel Picallo , Adolfo Anta , Bart De Schutter

Phasor Measurement Unit (PMU) technology is increasingly used for real-time monitoring applications, especially line outage detection and identification (D&I) in the power system. Current outage D&I schemes either assume a full PMU…

Systems and Control · Electrical Eng. & Systems 2020-09-08 Xiaozhou Yang , Nan Chen , Chao Zhai

The goal of this paper is to study the impact of the dynamic nature of bus voltage magnitudes and phase angles, which constitute the state of the power system, on the phasor measurement unit (PMU) placement problem. To facilitate this…

Systems and Control · Computer Science 2013-11-18 K. G. Nagananda

This paper introduces an algorithm able to detect and localize the occurrance of a fault in an Active Distribution Network, using the measurements collected by Phasor Measurement Units (PMUs). First, a basic algorithm that works under the…

Systems and Control · Electrical Eng. & Systems 2022-04-13 Francesco Conte , Fabio D'Agostino , Bruno Gabriele , Giacomo-Piero Schiapparelli , Federico Silvestro

The problem of effective use of Phasor Measurement Units (PMUs) to enhance power systems awareness and security is a topic of key interest. The central question to solve is how to use this new measurements to reconstruct the state of the…

Systems and Control · Electrical Eng. & Systems 2020-04-16 Alexey Bobtsov , Romeo Ortega , Nikolay Nikolaev , Johannes Schiffer , M. Nicolai L. Lorenz-Meyer

In this paper the empirical observability Gramian calculated around the operating region of a power system is used to quantify the degree of observability of the system states under specific phasor measurement unit (PMU) placement. An…

Optimization and Control · Mathematics 2014-10-08 Junjian Qi , Kai Sun , Wei Kang

This paper presents an information-theoretic approach to address the phasor measurement unit (PMU) placement problem in electric power systems. Different from the conventional 'topological observability' based approaches, this paper…

Optimization and Control · Mathematics 2012-01-16 Qiao Li , Tao Cui , Yang Weng , Rohit Negi , Franz Franchetti , Marija D. Ilic

Phasor measurement units (PMUs) have the advantage of providing direct measurements of power states. However, as the number of PMUs in a power system is limited, the traditional supervisory control and data acquisition (SCADA) system cannot…

Systems and Control · Computer Science 2016-07-12 Jian Du , Shaodan Ma , Yik-Chung Wu , H. Vincent Poor

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it…

Systems and Control · Electrical Eng. & Systems 2020-10-16 Hamed Haggi , Wei Sun , Junjian Qi

To provide real-time visibility of physics-based states, phasor measurement units (PMUs) are deployed throughout power networks. PMU data enable real-time grid monitoring and control -- and are essential in transitioning to smarter grids.…

Systems and Control · Electrical Eng. & Systems 2024-10-23 Mohamad H. Kazma , Ahmad F. Taha

A significant portion of the literature on fault localization assumes (more or less explicitly) that there are sufficient reliable measurements to guarantee that the system is observable. While several heuristics exist to break the…

Systems and Control · Computer Science 2018-09-12 Mahdi Jamei , Anna Scaglione , Sean Peisert

Phasor Measurement Units (PMUs) are measurement devices long used in transmission systems and today even more essential for a proper monitoring of distribution grids. The expected massive penetration of distributed energy resources (DERs)…

Systems and Control · Electrical Eng. & Systems 2020-03-03 Carlo Guarnieri Calo\' Carducci , Gianluca Lipari , Nicola Giaquinto , Ferdinanda Ponci , Antonello Monti