English
Related papers

Related papers: Microstructured Plastic Scintillators For Beam Pro…

200 papers

The main challenges posed by the design of future Positron Emission Tomography machines are the improvement of the spatial and timing resolution and the combined operation with magnetic resonance. The Micro Pixel Photon Counter by Hamamatsu…

Medical Physics · Physics 2008-05-06 N. D'Ascenzo , E. Garutti , M. Goettlich , H. C. Schultz-Coulon , A. Tadday

START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs…

As a prototype detector for the SHiP Surrounding Background Tagger (SBT), we constructed a cell (120 cm x 80 cm x 25 cm) made from corten steel that is filled with liquid scintillator (LS) composed of linear alkylbenzene (LAB) and…

Results are presented on R&D efforts to design and build large size veto panels, optimized for underground low background experiments, in the most efficient and economical way using commercially available components. A variety of plastic…

Instrumentation and Detectors · Physics 2015-06-18 W. Bugg , Yu. Efremenko , S. Vasilyev

At high luminosity areas, beam loss monitor with fast response and high radiation resistance is crucial for accelerator operation. In this article, we report the design and test results of a fast response and radiation-resistant…

Instrumentation and Detectors · Physics 2023-03-01 Yuanjing Ji , Zebo Tang , Chen Li , Xin Li , Ming Shao

The results obtained in laboratory tests, using scintillator bars read by silicon photomultipliers are reported. The present approach is the first step for designing a precision tracking system to be placed inside a free magnetized volume…

Instrumentation and Detectors · Physics 2017-01-04 S. Cecchini , I. D'Antone , L. Degli Esposti , I. Lax , G. Mandrioli , N. Mauri , L. Pasqualini , L. Patrizii , M. Pozzato , G. Sirri , M. Tenti

In recent years, a number of purpose-built scintillator-based polarimeters have studied bright astronomical sources for the first time in the hard X-ray band (tens to hundreds of keV). The addition of polarimetry can help data…

Instrumentation and Methods for Astrophysics · Physics 2019-08-08 Rakhee Kushwah , Nirmal K. Iyer , Mózsi Kiss , Theodor A. Stana , Mark Pearce

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the…

Accelerator Physics · Physics 2024-06-24 H. Piekarz , A. Romanov , R. Thurman-Keup , V. Shiltsev

Cosmic-ray muons, owing to their high penetration power and abundance, have been widely employed as a natural probe in experimental particle physics. We developed a meter-scale cosmic-ray muon telescope, consisting of two parallel…

High Energy Physics - Experiment · Physics 2026-05-07 Yan Niu , Anqing Wang , Xiangxiang Ren , Dong Liu , Meng Wang

A comparative study of the neutron-$\gamma$ Pulse Shape Discrimination (PSD) with seven organic scintillators is performed using an identical setup and digital electronics. The scintillators include plastics (EJ-299-33 and a plastic…

Instrumentation and Detectors · Physics 2020-11-30 M. Sénoville , F. Delaunay , M. Pârlog , N. L. Achouri , N. A. Orr

Rapid identification of microparticles in liquid is an important problem in environmental and biomedical applications such as for microplastic detection in water sources and physiological fluids. Existing spectro-scopic techniques are…

Applied Physics · Physics 2024-11-20 Yagmur Ceren Alatas , Uzay Tefek , Sayedus Salehin , Hashim Alhmoud , M. Selim Hanay

The advanced imaging and delivery techniques in proton therapy allow conformal high-dose irradiation of the target volume with high accuracy using pencil beam scanning or beam shaping apertures. These irradiation methods increasingly…

The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such…

Accelerator Physics · Physics 2015-11-09 R. Thurman-Keup , M. Alvarez , J. Fitzgerald , C. Lundberg , P. Prieto , M. Roberts , J. Zagel , W. Blokland

Three-dimensional finely grained plastic scintillator detectors bring many advantages in particle detectors, allowing a massive active target which enables a high-precision tracking of interaction products, excellent calorimetry and a…

We propose a new type segmented antineutrino detector made of plastic scintillators for the nuclear safeguard application. A small prototype was built and tested to measure background events. A satisfactory unmanned field operation of the…

Instrumentation and Detectors · Physics 2012-09-24 Yasuhiro Kuroda , Shugo Oguri , Yo Kato , Ryoko Nakata , Yoshizumi Inoue , Chikara Ito , Makoto Minowa

A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…

Instrumentation and Detectors · Physics 2017-09-20 B. B. Wiggins , Varinderjit Singh , J. Vadas , J. Huston , T. K. Steinbach , S. Hudan , R. T. deSouza

Conceiving the possibility of using plastic scintillator bars as robust detectors for antineutrino detection for the remote reactor monitoring and nuclear safeguard application we study expected basic performance by Monte Carlo simulation.…

Instrumentation and Detectors · Physics 2016-10-20 A. Sh. Georgadze , V. M. Pavlovych , O. A. Ponkratenko , D. A. Litvinov

A pixelated silicon detector, developed originally for particle physics experiments, was used for a beam profile measurement of a Co-60 irradiator in a water phantom. The beam profile was compared to a profile measured with a pinpoint…

We have characterised Water-based Liquid Scintillator (WbLS) using low energy protons, UV-VIS absorbance, and fluorescence spectroscopy. We have also developed and validated a simulation model that describes the behaviour of WbLS in our…

This article reports on the development and experimental results of commercial plasma display panels adapted for their potential use as micropattern gas radiation detectors. The plasma panel sensors (PPS) design an materials include glass…

‹ Prev 1 3 4 5 6 7 10 Next ›