Related papers: Fast Single-Quantum Measurement with a Multi-Ampli…
We introduce a novel method that we call Single-Shot Cross-Spectroscopy (SSCS), for extracting the auto- and cross-power spectral densities of dephasing noise of a qubit pair. The method uses straightforward input, namely single-shot…
Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used…
The readout noise for Charge-Coupled Devices (CCDs) has been the main limitation when using these detectors for measuring small amplitude signals. A readout system for a new scientific, low noise CCD is presented in this paper. The Skipper…
Digital correlated double sampling (DCDS), a readout technique for charge-coupled devices (CCD), is gaining popularity in astronomical applications. By using an oversampling ADC and a digital filter, a DCDS system can achieve a better…
Fault-tolerant quantum information processing with flawed qubits and gates requires highly efficient, quantum non-demolition (QND) qubit readout. In superconducting circuits, qubit readout using coherent light with fidelity above 99% has…
Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detection technology that can, in principle, provide significantly greater responsivity and improved noise performance than traditional charge coupled device (CCD)…
Superconducting qubits are a leading platform for scalable quantum computing and quantum error correction. One feature of this platform is the ability to perform projective measurements orders of magnitude more quickly than qubit…
The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge…
The measurement of a quantum system is often performed by encoding its state in a single observable of a light field. The measurement efficiency of this observable can be reduced by loss or excess noise on the way to the detector. Even a…
Magnetic microcalorimeters (MMCs) are cryogenic, energy-dispersive single-particle detectors providing excellent energy resolution, intrinsically fast signal rise time, quantum efficiency close to 100\%, large dynamic range as well as…
One of the biggest challenges impeding the progress of Metal-Oxide-Silicon (MOS) quantum dot devices is the presence of disorder at the Si/SiO$_2$ interface which interferes with controllably confining single and few electrons. In this work…
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which…
Repeating a gate sequence multiple times amplifies systematic errors coherently, making it a useful tool for characterizing quantum gates. However, the precision of such an approach is limited by low-frequency noises, while its efficiency…
Superconducting transition-edge sensor (TES) detectors have been the standard in Cosmic Microwave Background experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay…
In the past 10 years, two design innovations, the introduction of low internal gain (LGAD) and of resistive read-out (RSD), have radically changed the performance of silicon detectors. The LGAD mechanism, increasing the signal-to-noise…
We characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum…
While single-photon counting is routinely achieved in the optical domain, operational single microwave photon detectors (SMPDs) have only recently been demonstrated. SMPDs are critical for sensing weak signals from incoherent emitters, with…
Quantum mechanics can strongly influence the noise properties of mesoscopic devices. To probe this effect we have measured the current fluctuations at high-frequency (5-90G Hz) using a superconductor-insulator-superconductor tunnel junction…
The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited…
Muon imaging technology is an innovative imaging technique that can be applied in volcano imaging, heavy nuclear material detection, and archaeological research. The Micromegas detector is a promising choice for muon imaging due to its high…