English
Related papers

Related papers: Multi-energy X-ray linear-array detector enabled b…

200 papers

The spectroscopic techniques for time-resolved fine analysis of matter require coherent X-ray radiation with femtosecond duration and high average brightness. Seeded free-electron lasers (FELs), which use the frequency up-conversion of an…

Scintillators convert X-ray energy into visible or near-visible photons, enabling applications in high-energy particle detection and X-ray imaging. Increasing scintillator thickness improves X-ray absorption but degrades spatial resolution…

Optics · Physics 2026-05-19 Seou Choi , Sachin Vaidya , Charles Roques-Carmes , Marin Soljačić

Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods:…

Scintillation light is used in liquid argon (LAr) neutrino detectors to provide a trigger signal, veto information against cosmic rays, and absolute event timing. In this work, we discuss additional opportunities offered by detectors with…

Instrumentation and Detectors · Physics 2015-01-27 M. Sorel

Muon tomography is a non-destructive imaging technique that uses cosmic-ray muons to probe dense materials. Bar scintillator and scintillating fiber detectors equipped with one-dimensional SiPM arrays offer compact, high-resolution…

Instrumentation and Detectors · Physics 2026-04-06 Chenghan Lv , Kun Hu , Huiling Li , Hui Liang , Cong Liu , Hongbo Wang , Zibing Wu , Weiwei Xu

Highly collimated betatron radiation from a laser wakefield accelerator is a promising tool for spectroscopic measurements. Therefore there is a requirement to create spectrometers suited to the unique properties of such a source. We…

X-radiography (X-ray imaging) is a widely used imaging technique in art investigation. It can provide information about the condition of a painting as well as insights into an artist's techniques and working methods, often revealing hidden…

Image and Video Processing · Electrical Eng. & Systems 2020-09-18 Wei Pu , Barak Sober , Nathan Daly , Zahra Sabetsarvestani , Catherine Higgitt , Ingrid Daubechies , Miguel R. D. Rodrigues

A method of scanning mid-IR-laser microscopy has recently been proposed for the investigation of large-scale electrically and recombination-active defects in semiconductors and non-destructive inspection of semiconductor materials and…

Materials Science · Physics 2011-05-17 O. V. Astafiev , V. P. Kalinushkin , V. A. Yuryev

Scintillators are important materials for radiographic imaging and tomography (RadIT), when ionizing radiations are used to reveal internal structures of materials. Since its invention by R\"ontgen, RadIT now come in many modalities such as…

In clinical CT system, the x-ray tube emits polychromatic x-rays, and the x-ray detectors operate in the current-integrating mode. This physical process is accurately described by an energy-dependent non-linear integral equation. However,…

Medical Physics · Physics 2020-06-23 Wenxiang Cong , Bruno De Man , Ge Wang

A prototype plastic scintillating fibre based beam profile monitor was tested at the Heidelberg Ion Therapy Centre / \textit{Heidelberg Ionenstrahl Therapiezentrum} (HIT) in 2016 to determine its beam property reconstruction performance and…

Instrumentation and Detectors · Physics 2018-06-27 B. D. Leverington , M. Dziewiecki , L. Renner , R. Runze

A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap…

Medical Physics · Physics 2009-11-10 J. Pardo , L. Franco , F. Gomez , A. Iglesias , A. Pazos , J. Pena , R. Lobato , J. Mosquera , M. Pombar , J. Sendon

We have investigated the possibility of calibrating the PMTs of scintillation detectors, using the primary scintillation produced by X-rays to induce single photoelectron response of the PMT. The high-energy tail of this response, can be…

The color X-ray camera (SLcam) is a full-field single photon imager. As stand-alone camera, it is applicable for energy and space-resolved X-ray detection measurements. The exchangeable poly-capillary optics in front of a beryllium entrance…

Instrumentation and Detectors · Physics 2015-06-11 A. Bjeoumikhov , G. Buzanich , N. Langhoff , I. Ordavo , M. Radtke , U. Reinholz , H. Riesemeier , O. Scharf , H. Soltau , R. Wedell

While mid-infrared radiation can be used to identify and quantify numerous chemical species, contemporary broadband mid-IR spectroscopic systems are often hindered by large footprints, moving parts and high power consumption. In this work,…

This paper introduces Spectral Incoherent Diffractive Imaging (SIDI) as a novel method for achieving dark-field imaging of nanostructures with heterogeneous oxidation states. With SIDI, shifts in photoemission profiles can be spatially…

Optics · Physics 2023-12-25 Tamme Wollweber , Kartik Ayyer

X-ray energy spectrum plays an essential role in computed tomography (CT) imaging and related tasks. Due to the high photon flux of clinical CT scanners, most of spectrum estimation methods are indirect and usually suffered from various…

Medical Physics · Physics 2017-06-14 Wei Zhao , Lei Xing , Qiude Zhang , Qingguo Xie , Tianye Niu

X-ray free electron laser (XFEL) can provide X-ray light with about four order of magnitude higher flux than synchrotron radiation. Pulse light from XFEL interacts with the target and the resulting photons are collected by detectors. The…

Instrumentation and Detectors · Physics 2021-10-13 Shuo Zhang , Jing-Kai Xia , Xu-Dong Ju

The evolution of X-ray detection technology has significantly enhanced sensitivity and spatial resolution in non-destructive imaging of internal structure. However, the problem of low luminescence and transparency of scintillator materials…

Optics · Physics 2025-07-16 Tatsunori Shibuya , Eichi Terasawa , Hiromi Kimura , Takeshi Fujiwara

Scintillators convert ionizing radiation into visible photons, enabling applications from cosmic ray detection to medical imaging. Two independent strategies for improving scintillator performance via nanoscale patterning have recently been…