English
Related papers

Related papers: Development of a low-background HPGe detector at K…

200 papers

A gamma counting station based on high-purity germanium (HPGe) detector was set up for the material screening of the PandaX dark matter experiments in the China Jinping Underground Laboratory. Low background gamma rate of 2.6 counts/min…

Instrumentation and Detectors · Physics 2016-12-21 Xuming Wang , Xun Chen , Changbo Fu , Xiangdong Ji , Xiang Liu , Yajun Mao , Hongwei Wang , Siguang Wang , Pengwei Xie , Tao Zhang

A new ultra low-level counting setup has been installed in the shallow-underground laboratory Felsenkeller in Dresden, Germany. It includes a high-purity germanium detector (HPGe) of 163\% relative efficiency within passive and active…

Instrumentation and Detectors · Physics 2023-02-09 S. Turkat , D. Bemmerer , A. Boeltzig , A. R. Domula , J. Koch , T. Lossin , M. Osswald , K. Schmidt , K. Zuber

Searches for new physics push experiments to look for increasingly rare interactions. As a result, detectors require increasing sensitivity and specificity, and materials must be screened for naturally occurring, background-producing…

Instrumentation and Detectors · Physics 2021-02-03 D. S. Leonard , I. S. Hahn , W. G. Kang , V. Kazalov , G. W. Kim , Y. D. Kim , E. K. Lee , M. H. Lee , S. Y. Park , E. Sala

A high efficiency, low background counting setup has been made at TIFR consisting of a special HPGe detector ($\sim$ 70%) surrounded by a low activity copper+lead shield. Detailed measurements are performed with point and extended geometry…

Instrumentation and Detectors · Physics 2014-08-21 N. Dokania , V. Singh , S. Mathimalar , V. Nanal , S. Pal , R. G. Pillay

We describe a new high-purity germanium (HPGe) detector setup for low-background {\gamma}-ray spectrometry. The GeMSE facility (Germanium Material and meteorite Screening Experiment) is dedicated to material screening for rare event…

Instrumentation and Detectors · Physics 2017-01-06 M. v. Sivers , B. A. Hofmann , Å. V. Rosén , M. Schumann

The next generation of low-background physics experiments will require the use of materials with unprecedented radio-purity. A gamma-counting facility at the Kimballton Underground Research Facility (KURF) has been commissioned to perform…

Nuclear Experiment · Physics 2011-05-25 P. Finnerty , S. MacMullin , H. O. Back , R. Henning , A. Long , K. T. Macon , J. Strain , R. M. Lindstrom , R. B. Vogelaar

We are currently setting up a facility for low-background gamma-ray spectrometry based on a HPGe detector. It is dedicated to material screening for the XENON and DARWIN dark matter projects as well as to the characterization of meteorites.…

Instrumentation and Detectors · Physics 2015-10-21 M. von Sivers , B. A. Hofmann , Å. V. Rosén , M. Schumann

Low capacitance, large volume, high purity germanium (HPGe) radiation detectors have been successfully employed in low-background physics experiments. However, some physical processes may not be detectable with existing detectors whose…

Instrumentation and Detectors · Physics 2015-12-18 Paul Barton , Mark Amman , Ryan Martin , Kai Vetter

The GeMSE (Germanium Material and meteorite Screening Experiment) facility operates a low-background HPGe crystal in an underground laboratory with a moderate rock overburden of 620$\,$m.w.e. in Switzerland. It has been optimized for…

High-purity germanium (HPGe) detectors used for low-background gamma ray spectrometry are usually operated under either a fairly low overburden of the order of one meter of water equivalent (mw.e.) or a high overburden of the order of…

High-purity germanium detectors are well suited to analysis the radioactivity of samples. In order to reduce the environmental background, low-activity lead and oxygen free copper are installed outside of the probe to shield gammas, outmost…

Low background gamma spectrometry employing HPGe detectors is a sensitive technique for measuring low-level radioactivity in environmental applications, material screening, and for rare decay searches. This work presents spectroscopic…

Instrumentation and Detectors · Physics 2023-08-24 Swati Thakur , Soni Devi , Sanjeet S. Kaintura , Katyayni Tiwari , Pushpendra P. Singh

We present the use of a low background counting facility, equipped with a p-type 80% relative efficiency HPGe detector, protected by active and passive shielding, and large enough to count a 10" photo-multiplier tube (PMT). A GEANT4…

Instrumentation and Detectors · Physics 2011-01-21 M. Fechner , C. Henson , J. Gaffiot , T. Lasserre , A. Letourneau , D. Lhuillier , G. Mention , Th. A. Mueller , R. Quéval , R. Svoboda

The gamma-ray background in the indoor environment has been measured up to 3 MeV to evaluate the feasibility of studying low cross-section (nanobarn to picobarn range) astrophysical reactions at the Facility for Research in Experimental…

Instrumentation and Detectors · Physics 2020-07-14 Sathi Sharma , M. Saha Sarkar

A low background germanium gamma ray spectrometer, GeTHU, has been installed at China JinPing underground Laboratory. The integral background count rate between 40 and 2700 keV was 0.6 cpm, and the origin was studied by Monte Carlo…

Instrumentation and Detectors · Physics 2014-03-10 Yuhao Mi , Hao Ma , Zhi Zeng , Jianping Cheng , Jian Su , Qian Yue

The application of a high purity germanium (HPGe) gamma spectrometer in determining the fuel element burnup in a future reactor is studied. The HPGe detector is exposed by a Co60 source with varying irradiation rate from 10 kcps to 150 kcps…

Instrumentation and Detectors · Physics 2013-05-07 Weihua Yan , Liguo Zhang , Zhao Zhang , Zhigang Xiao

In this work we present the characterization of a Broad Energy Germanium (BEGe) type High Purity Germanium (HPGe) detector, with a carbon fiber entrance window thickness of 0.6 mm and an active area of 6305 mm2, operated at shallow depth (~…

Instrumentation and Detectors · Physics 2023-10-20 O. Fawwaz , H. Shams , F. Arneodo , A. Di Giovanni

The main background above 3\,MeV for in-beam nuclear astrophysics studies with $\gamma$-ray detectors is caused by cosmic-ray induced secondaries. The two commonly used suppression methods, active and passive shielding, against this kind of…

Instrumentation and Detectors · Physics 2015-03-25 T. Szücs , D. Bemmerer , T. P. Reinhardt , K. Schmidt , M. P. Takács , A. Wagner , L. Wagner , D. Weinberger , K. Zuber
‹ Prev 1 2 3 10 Next ›