Related papers: The Effects of Peeling on Finite Element Method -b…
Magnetoencephalography (MEG) is an imaging technique used to measure the magnetic field outside the human head produced by the electrical activity inside the brain. The MEG inverse problem, identifying the location of the electrical sources…
EEG based brain state decoding has numerous applications. State of the art decoding is based on processing of the multivariate sensor space signal, however evidence is mounting that EEG source reconstruction can assist decoding. EEG source…
The success of stereoelectroencephalographic (SEEG) investigations depends crucially on the hypotheses on the putative location of the seizure onset zone. This information is derived from non-invasive data either based on visual analysis or…
The EEG source localization is an ill-posed problem. It involves estimation of the sources which outnumbers the number of measurements. For a given measurement at given time all sources are not active which makes the problem as sparse…
Optically-pumped magnetometers (OPM) -- next-generation magnetoencephalography (MEG) sensors -- may be placed directly on the head, unlike the more commonly used superconducting quantum interference device (SQUID) sensors, which must be…
We present a deep learning solution to the problem of localization of magnetoencephalography (MEG) brain signals. The proposed deep model architectures are tuned for single and multiple time point MEG data, and can estimate varying numbers…
A novel technique for Electroencephalogram (EEG) compression is proposed in this article. This technique models the intrinsic dependency inherent between the different EEG channels. It is based on dipole fitting that is usually used in…
Electroencephalography (EEG) source imaging aims to reconstruct the spatial distribution of neural activity within the brain from non-invasive scalp measurements. This inverse problem is severely ill-posed due to the low spatial resolution…
MEG and EEG are noninvasive functional neuroimaging techniques that provide recordings of brain activity with high temporal resolution, and thus provide a unique window to study fast time-scale neural dynamics in humans. However, the…
In this paper, we propose a novel source model for a magnetoencephalography (MEG) inverse problem that combines a conventional extended parametric approach and an imaging approach.Our aim is to separately identify a focal current source and…
Source localization in EEG represents a high dimensional inverse problem, which is severely ill-posed by nature. Fortunately, sparsity constraints have come into rescue as it helps solving the ill-posed problems when the signal is sparse.…
High temporal resolution measurements of human brain activity can be performed by recording the electric potentials on the scalp surface (electroencephalography, EEG), or by recording the magnetic fields near the surface of the head…
Background: Magneto- and Electro-encephalography record the electromagnetic field generated by neural currents with high temporal frequency and good spatial resolution, and are therefore well suited for source localization in the time and…
Source analysis of Electroencephalography (EEG) data requires the computation of the scalp potential induced by current sources in the brain. This so-called EEG forward problem is based on an accurate estimation of the volume conduction…
This paper deals with the EEG/MEG neuroimaging problem: given measurements of scalp electric potential differences (EEG: electroencephalogram) and extracranial magnetic fields (MEG: magnetoencephalogram), find the 3D distribution of the…
The source localization of the human brain activities is an important resource for the recognition of cognitive state, medical disorders and a better understanding of the brain in general. In this study, we have compared 51 mother wavelets…
Electromagnetic source imaging (ESI) requires solving a highly ill-posed inverse problem. To seek a unique solution, traditional ESI methods impose various forms of priors that may not accurately reflect the actual source properties, which…
Magnetoencephalography (MEG) provides dynamic spatial-temporal insight of neural activities in the cortex. Because the number of possible sources is far greater than the number of MEG detectors, the proposition to localize sources directly…
EDIT: A revised version of this article has been published in the SIAM Journal on Scientific Computing, see https://epubs.siam.org/doi/full/10.1137/23M1582874. In the revised version, the name of the approach was changed from "localized…
In this paper we present a new discretization strategy for the boundary element formulation of the Electroencephalography (EEG) forward problem. Boundary integral formulations, classically solved with the Boundary Element Method (BEM), are…