English
Related papers

Related papers: Long term experience with perfluorobutane in COMPA…

200 papers

A proximity focusing ring imaging Cherenkov detector, with the radiator consisting of two or more aerogel layers of different refractive indices, has been tested in 1-4 GeV/c pion beams at KEK. Essentially, a multiple refractive index…

This paper studies the performance of RPCs working with a new family of environment-friendly operating gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement…

Instrumentation and Detectors · Physics 2022-05-18 G. Proto , B. Liberti , R. Santonico , G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , A. Paoloni , E. Pastori , L. Pizzimento , A. Rocchi

The use of a nonhomogeneous aerogel radiator, i.e. one consisting of layers with different refractive indices, has been shown to improve the resolution of the Cherenkov angle measured with a proximity focusing RICH detector. In order to…

Instrumentation and Detectors · Physics 2008-11-26 Peter Krizan , Samo Korpar , Toru Iijima

Portable and cost-effective gas sensors are gaining demand for a number of environmental, biomedical and industrial applications, yet current devices are confined into specialized labs and cannot be extended to general use. Here, we…

Instrumentation and Detectors · Physics 2020-04-10 Giuseppe Antonacci , Jeroen Goyvaerts , Haolan Zhao , Bettina Baumgartner , Bernhard Lendl , Roel Baets

Results obtained by the RPC ECOgas@GIF++ Collaboration, using Resistive Plate Chambers operated with new, eco-friendly gas mixtures, based on Tetrafluoropropene and carbon dioxide, are shown and discussed in this paper. Tests aimed to…

The NA62 RICH detector is used for the separation of pions and muons in the momentum range 15 -- 35 GeV/c and is expected to provide a muon suppression factor better than $10^{-2}$. A prototype of the final detector equipped with about 400…

Instrumentation and Detectors · Physics 2019-08-14 E. Gersabeck

This paper proposes a new X-ray radiographic technique for measuring density uniformity of silica aerogels used as radiator in proximity-focusing ring-imaging Cherenkov detectors. To obtain high performance in a large-area detector, a key…

Instrumentation and Detectors · Physics 2012-12-17 Makoto Tabata , Yoshikiyo Hatakeyama , Ichiro Adachi , Takeshi Morita , Keiko Nishikawa

Driven by the urgent demand for efficient cooling in microelectronics and advanced thermal management systems, difluoromethane (R32/CH2F2) has emerged as a promising candidate owing to its favorable thermophysical properties, including high…

Soft Condensed Matter · Physics 2025-09-29 Abibat Adekoya-Olowofela , Sukriti Manna , Subramanian KRS Sankaranarayanan

This paper presents recent progress in the development and mass production of large-area hydrophobic silica aerogels for use as radiators in the aerogel-based ring-imaging Cherenkov (A-RICH) counter, which will be installed in the forward…

Most refrigerants currently used in air-conditioning systems, such as hydrofluorocarbons, are potent greenhouse gases and are being phased down. Large-scale molecular screening has been applied to the search for alternatives, but in…

Chemical Physics · Physics 2025-11-24 Adrien Goldszal , Diego Calanzone , Vincent Taboga , Pierre-Luc Bacon

Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must…

Instrumentation and Detectors · Physics 2016-06-28 M. Blatnik , K. Dehmelt , A. Deshpande , D. Dixit , N. Feege , T. K. Hemmick , B. Lewis , M. L. Purschke , W. Roh , F. Torales-Acosta , T. Videbaek , S. Zajac

Resistive Plate Chambers detectors are extensively used in several domains of Physics. In High Energy Physics, they are typically operated in avalanche mode with a high-performance gas mixture based on Tetrafluoroethane (C2H2F4), a…

Instrumentation and Detectors · Physics 2025-10-08 D. Ahmadi , M. Tytgat

A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the…

Instrumentation and Detectors · Physics 2019-08-14 C. Schill

The characterisation of the dynamic properties of viscoelastic monolayers of surfactants at the gasliquid interface is very important in the analysis and prediction of foam stability. With most of the relevant dynamic processes being rapid…

The environmental and economic benefits of recycling asphalt pavements have received much attention in recent years. Because of the increase in the cost of raw materials and energy carriers, the reuse of large portions of reclaimed asphalt…

Applied Physics · Physics 2019-06-03 Hamed Majidifard , Nader Tabatabaee , William Buttlar

Due to their simplicity and comparatively low cost, Resistive Plate Chambers are gaseous detectors widely used in high-energy and cosmic rays physics, when large detection areas are needed. However, the best gaseous mixtures are currently…

Instrumentation and Detectors · Physics 2022-03-01 Livia Terlizzi

A Comparative study has been performed on Resistive Plate Chambers made of different grades of bakelite paper laminates, produced and commercially available in India. The chambers, operated in the streamer mode using argon :…

Nuclear Experiment · Physics 2008-02-21 S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , S. Saha , M. K. Sharan , Y. P. Viyogi

We show that up to 90% reflectivity can be achieved by using guided plasmonic resonances in a one-dimensional periodic array of plasmonic nanoribbon. In general, to achieve strong reflection from a guided resonance system requires one to…

Optics · Physics 2018-12-13 Nathan Zhao , Zhexin Zhao , Ian Williamson , Salim Boutami , Bo Zhao , Shanhui Fan

The results of x-ray reflectivity studies of two oil/water (liquid/liquid) interfaces are inconsistent with recent predictions of the presence of a vapor-like depletion region at hydrophobic/aqueous interfaces. One of the oils,…

In recent years, the issue of radon emanation and diffusion has become a critical concern for rare decay experiments, such as JUNO and PandaX-4T. This paper introduces a detector design featuring a symmetric radon detector cavity for the…