English
Related papers

Related papers: Heading Error Compensation in a Portable Optical M…

200 papers

When optically pumped magnetometers are aimed for the use in Earth's magnetic field, the orientation of the sensor to the field direction is of special importance to achieve accurate measurement result. Measurement errors and inaccuracies…

Atomic Physics · Physics 2019-01-23 G. Oelsner , V. Schultze , R. IJsselsteijn , F. Wittkämper , R. Stolz

We experimentally investigate the influence of the orientation of optically pumped magnetometers in Earth's magnetic field. We focus our analysis to an operational mode that promises femtotesla field resolu-tions at such field strengths.…

Atomic Physics · Physics 2019-12-16 G. Oelsner , V. Schultze , R. IJsselsteijn , R. Stolz

Optically pumped atomic magnetometers (OPAMs) offer high sensitivity at room temperature and are increasingly considered for portable magnetic sensing in geomagnetic-field environments. Here we report a handheld-scale, single-beam scalar…

Atomic Physics · Physics 2026-01-14 Heonsik Lee , Hyunbeen Lee , Minseok Choi , Yoontae Hwang , Deok-Young Lee

Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear…

Atomic Physics · Physics 2025-02-20 Siqi Liu , Xueke Wang , Xiangdong Zhang , Wei Xiao , Dong Sheng

Optically pumped atomic magnetometers (OPMs) offer highly sensitive magnetic measurements using compact hardware, offering new possibilities for practical precision sensors. Double-resonance OPM operation is well suited to unshielded…

Optically pumped magnetometers (OPMs) are compact and lightweight sensors that can measure magnetic fields generated by current flow in neuronal assemblies in the brain. Such sensors enable construction of magnetoencephalography (MEG)…

We present a portable optically pumped magnetometer instrument for ultra-sensitive measurements within the Earth's magnetic field. The central part of the system is a sensor head operating a MEMS-based Cs vapor cell in the light-shift…

We demonstrate an all-optical single beam pulsed atomic magnetometer assisted by laser mode-hopping in a distributed Bragg reflector (DBR) laser. We implement a temporal sequence of the laser current, with sinusoidal current modulation…

Atomic Physics · Physics 2025-01-14 Ji Hoon Yoon , Sang Hyuk Hong , Taek Jeong , Sin Hyuk Yim , Kyu Min Shim , Sangkyung Lee

Miniaturized atomic magnetometers, particularly spin-exchange relaxation-free atomic magnetometers, have been emerging in clinical imaging applications such magnetocardiography and magnetoencephalography. Miniaturization, portability, and…

Atomic Physics · Physics 2022-04-28 Xiaojie Li , Zhihao Guo , Rui Yang , Yanying Feng

Alkali-metal atomic magnetometers suffer from heading errors in geomagnetic fields as the measured magnetic field depends on the orientation of the sensor with respect to the field. In addition to the nonlinear Zeeman splitting, the…

Atomic Physics · Physics 2021-06-09 W. Lee , V. G. Lucivero , M. V. Romalis , M. E. Limes , E. L. Foley , T. W. Kornack

Alkali-metal atomic magnetometry is widely used due to its high sensitivity and cryogen-free operation. However, when operating in geomagnetic field, it suffers from heading errors originating from nonlinear Zeeman (NLZ) splittings and…

Atomic Physics · Physics 2023-04-14 Rui Zhang , Dimitra Kanta , Arne Wickenbrock , Hong Guo , Dmitry Budker

Many advanced techniques have been developed, tested and implemented in the last decades in almost all circular accelerators across the world to measure the linear optics. However, the greater availability and accuracy of beam diagnostics…

Accelerator Physics · Physics 2018-04-18 Andrea Franchi

Ultra-sensitive measurement of the magneto-optical rotation, due to interaction of linearly-polarized light passing through room-temperature Rb 85 atoms, in response to change in longitudinal magnetic field (\delta B_z ) is demonstrated…

Instrumentation and Detectors · Physics 2019-04-04 T. J. Vineeth Francis , Rashmi Ranjan Suna , P. K. Madhu , Nirmal K. Viswanathan , G. Rajalakshmi

We demonstrate how to measure in situ for heading errors of optically pumped magnetometers (OPMs) in the challenging parameter regime of compact vapor cells with imperfect optical pumping and high buffer gas pressure. For this, we utilize…

The heading error has been known to be caused mainly by the nonlinear Zeeman effect and the orientation-dependent light shift. In this work, we find that the nuclear Zeeman effect can also have a significant impact on the heading errors,…

Quantum Physics · Physics 2021-12-21 Yue Chang , Yu-Hao Guo , Shuang-Ai Wan , Jie Qin

A self-oscillating magnetometer based on the nonlinear magneto-optical rotation effect with separate modulated pump and unmodulated probe beams is demonstrated. This device possesses a bandwidth exceeding $1\khz$. Pump and probe are…

Atomic Physics · Physics 2009-11-13 J. M. Higbie , E. Corsini , D. Budker

We present a novel approach allowing an optically pumped magnetometer (OPM) to be operated within Earth's magnetic field as a vector magnetometer whose sensitive axis can be freely defined. This approach enables the measurement of any…

Instrumentation and Detectors · Physics 2024-08-20 Thomas Schönau , Theo Scholtes , Florian Wittkämper , Alexander Sekels , Stefan Hiebel , Gregor Oelsner , Ronny Stolz

Magnetic Detection Electrical Impedance Tomography is a novel technique that could enable non-invasive imaging of fast neural activity in the brain. However, commercial magnetometers are not suited to its technical requirements.…

Medical Physics · Physics 2024-12-19 Kai Mason , Florencia Maurino-Alperovich , Kirill Aristovich , David Holder

To address the demands in healthcare and industrial settings for spatially resolved magnetic imaging, we present a modular optically pumped magnetometer (OPM) system comprising a multi-sensor array of highly sensitive quantum magnetometers.…

Detection dead zones and heading errors induced by light shifts are two important problems in optically pumped scalar magnetometry. We introduce an atomic orientation based single-beam magnetometry scheme to simultaneously solve these…

Atomic Physics · Physics 2022-05-18 Qianqian Yu , Siqi Liu , Chunqi Yuan , Dong Sheng
‹ Prev 1 2 3 10 Next ›