Related papers: B-CLEAN-SC: CLEAN-SC for broadband sources
Traditional beamforming of medical ultrasound images relies on sampling rates significantly higher than the actual Nyquist rate of the received signals. This results in large amounts of data to store and process, imposing hardware and…
Speech enhancement and source localization has been active research for several decades with a wide range of real-world applications. Recently, the Deep Complex Convolution Recurrent network (DCCRN) has yielded impressive enhancement…
We present a two-channel deconvolution method that decomposes images into a parametric point-source channel and a pixelized extended-source channel. Based on the central idea of the deconvolution algorithm proposed by Magain, Courbin & Sohy…
Aims: To formulate, implement, and validate a user-independent release of CLEAN for Fourier-based image reconstruction of hard X-rays flaring sources. Methods: CLEAN is an iterative deconvolution method for radio and hard X-ray solar…
A new method for improving the resolution of astronomical images is presented. It is based on the principle that sampled data cannot be fully deconvolved without violating the sampling theorem. Thus, the sampled image should not be…
The most realistic information about the transparent sample such as a live cell can be obtained only using bright-field light microscopy. At high-intensity pulsing LED illumination, we captured a primary 12-bit-per-channel (bpc) response…
For high-precision cosmic microwave background (CMB) experiments, contamination from extragalactic point sources is a major concern. It is therefore useful to be able to detect and discard point source contaminated pixels using the map…
A functional approximation to implement Bayesian source separation analysis is introduced and applied to separation of the Cosmic Microwave Background (CMB) using WMAP data. The approximation allows for tractable full-sky map…
In this paper we revisit the classical problem of estimating a signal as it impinges on a multi-sensor array. We focus on the case where the impinging signal's bandwidth is appreciable and is operating in a broadband regime. Estimating…
The standard technique used by commercial medical ultrasound systems to form B-mode images is delay and sum (DAS) beamforming. However, DAS often results in limited image resolution and contrast, which are governed by the center frequency…
Prior Arbitrary-Scale Image Super-Resolution (ASISR) methods often experience a significant performance decline when the upsampling factor exceeds the range covered by the training data, introducing substantial blurring. To address this…
Like the ordinary power spectrum, higher-order spectra (HOS) describe signal properties that are invariant under translations in time. Unlike the power spectrum, HOS retain phase information from which details of the signal waveform can be…
It is a challenging task to accurately perform semantic segmentation due to the complexity of real picture scenes. Many semantic segmentation methods based on traditional deep learning insufficiently captured the semantic and appearance…
Ptychography is an attractive advance of coherent diffraction imaging (CDI), which can provide high lateral resolution and wide field of view. The theoretical resolution of ptychography is dose-limited, therefore making ptychography…
Beamforming techniques that employ Singular Value Decomposition (SVD) are commonly used in Multi-Input Multi-Output (MIMO) wireless communication systems. In the absence of channel coding, when a single symbol is transmitted, these systems…
In the study of condensed matter physics, spectral information plays an important role for understand the mechanism of materials. However, it is difficult to obtain the spectrum directly through experiments or simulation. For example, the…
The objective of deep learning methods based on encoder-decoder architectures for music source separation is to approximate either ideal time-frequency masks or spectral representations of the target music source(s). The spectral…
The cosmic microwave background (CMB) is a significant source of knowledge about the origin and evolution of our universe. However, observations of the CMB are contaminated by foreground emissions, obscuring the CMB signal and reducing its…
In this work we present a new algorithm for data deconvolution that allows the retrieval of the target function with super-resolution with a simple approach that after a precis e measurement of the instrument response function (IRF), the…
Measured acoustic data can be contaminated by noise. This typically happens when microphones are mounted in a wind tunnel wall or on the fuselage of an aircraft, where hydrodynamic pressure fluctuations of the Turbulent Boundary Layer (TBL)…