Related papers: Design Status of BCC Cryomodule for LCLS-II HE

200 papers

The Linac Coherent Light Source (LCLS) is an X-ray science facility at SLAC National Accelerator Laboratory. The LCLS-II project (an upgrade to LCLS) is in the commissioning phase; the LCLS-II-HE (High Energy) project is another upgrade to…

In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These devices will be…

Accelerator Physics · Physics 2017-04-27 M. W. McGee , S. K. Chandrasekaran , A. C. Crawford , E. Harms , J. Leibfritz , G. Wu

This paper describes the cryogenic system for the Cryomodule Test Stand (CMTS) at the new Cryomodule Test Facility (CMTF) located at Fermilab. CMTS is designed for production testing of the 1.3 GHz and 3.9 GHz cryomodules to be used in the…

Accelerator Physics · Physics 2017-12-05 Michael White , Benjamin Hansen , Arkadiy Klebaner

An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were processed with a novel nitrogen doping treatment to improve gradient performance. The…

An introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and…

Accelerator Physics · Physics 2009-02-19 M. Wendt , T. Lefevre , C. Simon , S. Vilalte

Quality factor is a primary cost driver for high energy, continuous wave (CW) SRF linacs like the LCLS-II X-ray free electron laser currently under construction. Taking this into account, several innovations were introduced in the LCLS-II…

Accelerator Physics · Physics 2019-01-09 G. Wu , A. Grassellino , E. Harms , N. Solyak , A. Romanenko , C. Ginsburg , R. Stanek

The superconducting RF linac for LCLS-II calls for 1.3 GHz 9-cell cavities with an average intrinsic quality factor Q0 of 2.7x10^10 at 2 K and 16 MV/m accelerating gradient. Two niobium 9-cell cavities, prepared with nitrogen-doping at…

The commissioning of two cryomodule components is underway at Fermilab's Superconducting Radio Frequency (SRF) Accelerator Test Facility. The research at this facility supports the next generation high intensity linear accelerators such as…

Accelerator Physics · Physics 2012-08-10 M. W. McGee , J. Leibfritz , A. Martinez , Y. Pischalnikov , W. Schappert

In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These include a prototype…

Accelerator Physics · Physics 2016-07-04 M. W. McGee , T. Arkan , T. Peterson , Z. Tang , S. Boo , M. Carrasco , E. Daly , N. Huque

Microphonics causes the cavity to detune. This study discusses the microphonics of sixteen 1.3 GHz cryomodules, 14 for LCLS-II and 2 for LCLS-II HE tested at CMTF. The peak detuning, as well as the RMS detuning for each cryomodule, will be…

Fermi National Accelerator Laboratory is constructing a superconducting 1.3 GHz cryomodule test facility located at the New Muon Lab building. The facility will be used for testing and validating cryomodule designs as well as support…

Accelerator Physics · Physics 2012-06-29 A. Martinez , A. L. Klebaner , J. C. Theilacker , B. D. DeGraff , J. Leibfritz

Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped superconducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports.…

Accelerator Physics · Physics 2024-08-21 A. Lunin , T. Khabiboulline , A. Sukhanov , V. Yakovlev

Fermi National Accelerator Laboratory is constructing an Advanced Accelerator Research and Development facility at New Muon Lab. The cryogenic infrastructure in support of the initial phase of the facility consists of two Tevatron style…

Accelerator Physics · Physics 2012-09-13 A. Martinez , A. L. Klebaner , J. C. Theilacker , B. D. DeGraff , M. White , G. S. Johnson

An interlock system has been designed for the Fermilab Cryo-module Test Stand (CMTS), a test bed for the cryomodules to be used in the upcoming Linac Coherent Light Source 2 (LCLS-II) project at SLAC. The interlock system features 8…

Accelerator Physics · Physics 2017-05-02 T. Petersen , J. S. Diamond , D. McDowell , D. Nicklaus , P. S. Prieto , A. Semenov

Commissioning and operation of the first Tesla-style Cryomodule (CM-1) at Fermilab was concluded in recent months. A second Tesla Type III+ module, RFCA002, will be replacing it. CM-1 is the first 8-cavity ILC style cryomodule to be built…

CEPC will use 650 MHz cavities for the collider. Each collider cryomodule contains six 650 MHz 2-cell cavities, which is totally new. Therefore, new helium vessel and tuner are designed for the 650 MHz 2-cell cavity. Also, a test…

Accelerator Physics · Physics 2023-01-10 Z. H. Mi , Z. Q. Li , P. Sha , J. Y. Zhai , F. S. He , Q. Ma , B. Q. Liu , X. Y. Zhang , R. X. Han , F. B. Meng , H. J. Zheng

The present contribution reports the design of the pre-production Single Spoke Resonator Type 2 Cryomodule (ppSSR2 CM), developed in the framework of the PIP-II project at Fermilab. The innovative design is based on a structure, the…

A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3…

The superconducting cavities in the continuous wave (CW) linacs of LCLS-II are designed to operate at 2 K, where cooling costs are very expensive. One source of heat is presented by the higher order mode (HOM) power deposited by the beam.…

Accelerator Physics · Physics 2014-11-07 K. Bane , C. Nantista , C. Adolphsen , T. Raubenheimer , A. Saini , N. Solyak , V. Yakovlev

LCLS-II is currently in its commissioning phase at SLAC. It is an X-ray FEL driven by a CW superconducting LINAC. The beam injector plays a crucial role in the overall performance of the accelerator, and is critical to the final electron…