Related papers: Modelling the response of a CsI(Tl)-PiN photodiode…
We report on the scintillation characterization of a 1 cm^3 CsI(Tl) crystal coupled to a 6 x 6 mm^2 SiPM read out with a custom transimpedance amplifier at cryogenic temperatures. The crystal was prepared with optical-grade surfaces and…
An array of eight CsI(Tl) detectors has been set up to measure the light charged particles in nuclear reactions using heavy ions from the Pelletron Linac Facility, Mumbai. The energy response of CsI(Tl) detector to $\alpha$-particles from 5…
The calorimeter, range detector and active target elements of the T2K near detectors rely on the Hamamatsu Photonics Multi-Pixel Photon Counters (MPPCs) to detect scintillation light produced by charged particles. Detailed measurements of…
The Chinese large-area violet-light-sensitive silicon photodiode PIN is one of the candidates of the lead tungstate crystal detector readout component of the photon spectrometer in the large heavy ion collision experiment. The PIN diode was…
Scintillation detector has lower energy resolution for Gamma-ray as compared to semiconductor detector, better spectra analysis method is essential to traditional method. A model for describing the response function of scintillation…
Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use…
The performance of a Si PIN diode (type Hamamatsu S3590-06) as an energy sen- sitive detector operating at cryogenic temperatures (~10 K) and in magnetic fields up to 11 T was investigated, using a 207Bi conversion electron source. It was…
Si-based photodetectors satisfy the criteria of low-cost and environmental-friendly, and can enable the development of on-chip complementary metal-oxide-semiconductor (CMOS)-compatible photonic systems. However, extending their…
Following optical pulses ($\lambda=405~\text{nm}$) on titanium nitride (TiN) Microwave Kinetic Inductance Detectors (MKIDs) cooled down at temperatures $T \le T_c / 20$ ($T_c \simeq 4.6~\text{K}$), we observe a large phase-response…
Al/Si photodiode were prepared by successive of deposition of Aluminum thin films on p-type Si (100) using coprecipitation method by evaporator in vacuum 2.0E-4 torr. The measured signals are attributed to a spectral response, which appears…
Single-crystal synthetic diamond sensors have been widely used in radiation dosimetry and beam diagnostics. The foreseen harsh radiation environment in electron-positron colliders at the luminosity frontier requires a thorough investigation…
We present a compact on-chip resonator enhanced silicon-MSM photodetector in $850$ $nm$ wavelength band for communication and lab-on-chip bio-sensing applications. We report the highest responsivity of 0.81 A/W for a 5 $\mu m$ long device.…
This paper describes the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification…
A light-emitting diode (LED) pulser for testing the low-rate response of a photomultiplier tube (PMT) to scintillator-like pulses has been designed, developed, and implemented. This pulser is intended to simulate 80 ns full width at half…
Characteristics improvement of photon/plasmon detectors have been the subject of several investigations in the area of plasmonic integrated circuits. Among different suggestions, Silicon-based Metal-Semiconductor-Metal (MSM) waveguides are…
Thanks to intrinsically short electronic relaxation on the ps time scale, III-V semiconductor unipolar devices are ideal candidates for ultrahigh-speed operation at mid-infrared frequencies. In this work, antenna-coupled, GaAs-based multi…
The light output of the 324 CsI(Tl) scintillators of INDRA has been measured over a large range both in energy: 1 - 80 AMeV and in atomic number of incident ions: Z = 1 - 60. An analytical expression for the nonlinear total light response…
Silicon Carbide (SiC) demonstrates significant potential for high-energy particle detection in complex radiation environments due to its exceptional radiation resistance, excellent environmental adaptability, and fast response time.…
Over the last decade one of the most significant technological advances made in the field of radiation detectors for nuclear medicine was the development of Silicon Photomultipler (SiPM) sensors. At present a only small number of SiPM based…
A phototransistor is a promising candidate as an optical power monitor in Si photonic circuits since the internal gain of photocurrent enables high sensitivity. However, state-of-the-art waveguide-coupled phototransistors suffer from a…