English
Related papers

Related papers: Methods for Simulating TOF-PET in TOPAS Using a Lo…

200 papers

This article describes the development of an active Thomson Parabola ion spectrometer designed to measure the energy spectra of different multi-MeV ion species generated in laser-plasmas interactions. To do so, GEANT4 optical simulations…

Instrumentation and Detectors · Physics 2025-09-03 A. Huber , D. Raffestin , F. Hannachi , M. Huault , J. Jouve , A. Maitrallain , P. Nicolaï , B. Zielbauer , M. Tarisien

A set of physics models for nanodosimetry simulation is being re-engineered for use in Geant4-based simulations. This extension of Geant4 capabilities is part of a larger scale R&D project for multi-scale simulation involving adaptable,…

Computational Physics · Physics 2009-12-10 E. Gargioni , V. Grichine , M. G. Pia

The anticipated high sensitivity and the science goals of the next generation X-ray space missions, like the International X-ray Observatory or Simbol-X, rely on a low instrumental background, which in turn requires optimized shielding…

Instrumentation and Methods for Astrophysics · Physics 2009-12-02 S. Hauf , M. Kuster , M. G. Pia , Z. Bell , U. Briel , R. Chipaux , D. H. H. Hoffmann , E. Kendziorra , P. Laurent , L. Strüder , C. Tenzer , G. Weidenspointer , A. Zoglauer

A general virtual neutron experiment for TOF neutron reflectometer was introduced, including instrument simulation, sample modeling, detector simulation and data reduction to mimic the routine of real experimental process and data…

Instrumentation and Detectors · Physics 2017-01-18 Taisen Zuo , Haolai Tian , Yanyan Wang , Rong Du , Ming Tang , Junrong Zhang , Fang-Wei Wang , Yuan-Bo Chen

Depth distributions of positron-emitting nuclei in PMMA phantoms are calculated within a Monte Carlo model for Heavy-Ion Therapy (MCHIT) based on the GEANT4 toolkit (version 8.0). The calculated total production rates of $^{11}$C, $^{10}$C…

Medical Physics · Physics 2007-05-23 Igor Pshenichnov , Igor Mishustin , Walter Greiner

Purpose: To develop a Monte Carlo (MC) therapeutic dose calculation toolkit of a recently released ring gantry linac in Geant4 (Version 10.7) for secondary dose validation of radiotherapy plan. Methods: For the Halcyon (Varian Medical…

Medical Physics · Physics 2022-10-04 Ruirui Liu , Zhen Ji , Xiandong Zhao , Tianyu Zhao , Abhishek Sethi , Daren Sawkey , Bin Cai

We are investigating a prototype virtual pinhole positron emission tomography (VP-PET) system for small animal imaging applications. The PET detector modules were made up of 1.3 mm lutetium-yttrium oxyorthosilicate (LYSO) arrays, and the…

Medical Physics · Physics 2018-01-11 Zheng-Qian Ye , Ying-Guo Li , Tian-Quan Wang , Ya-Ming Fan , Yong-Zhi Yin , Xi-Meng Chen

Low-dose Positron Emission Tomography (PET) imaging presents a significant challenge due to increased noise and reduced image quality, which can compromise its diagnostic accuracy and clinical utility. Denoising diffusion probabilistic…

Image and Video Processing · Electrical Eng. & Systems 2025-03-03 Boxiao Yu , Savas Ozdemir , Jiong Wu , Yizhou Chen , Ruogu Fang , Kuangyu Shi , Kuang Gong

Novel TOF-PET scanner solutions demand, apart from the state of the art detectors, software for fast processing of the gathered data, monitoring of the whole scanner and reconstruction of the PET image. In this article we present an…

The correctness and precision of particle physics simulation software, such as Geant4, is expected to yield results that closely align with real-world observations or well-established theoretical predictions. Notably, the accuracy of these…

Computational Physics · Physics 2024-09-11 Angel Bueno Rodriguez , Felix Sattler , Maximilian Perez Prada , Maurice Stephan , Sarah Barnes

The search for new comparably light (well below the electroweak scale) feebly interacting particles is an exciting possibility to explain some mysterious phenomena in physics, among them the origin of Dark Matter. The sensitivity study…

X-ray fluorescence computed tomography based on sheet-beam can save a huge amount of time to obtain a whole set of projections using synchrotron. However, it is clearly unpractical for most biomedical research laboratories. In this paper,…

Medical Physics · Physics 2017-03-07 Shanghai Jiang , Peng He , Luzhen Deng , Mianyi Chen , Biao Wei

We evaluate the performance of an Omnivision OV5647 CMOS image sensor (5 Mp) for detecting radiation from Sr90 and Cs137 sources. Our experimental setup uses a Raspberry Pi 3 mini-computer for data acquisition, with image processing using…

High Energy Physics - Experiment · Physics 2025-06-18 M. Bonnett Del Alamo , R. Helaconde , C. Soncco , J. Bazo , A. M. Gago

Time-Over-Threshold (TOT) technique is being used widely due to its implications in developing the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge…

The neutron sensitivity of the C$_6$D$_6$ detector setup used at n_TOF for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the…

Instrumentation and Detectors · Physics 2014-06-27 TOF collaboration , P. Žugec , N. Colonna , D. Bosnar , S. Altstadt , J. Andrzejewski , L. Audouin , M. Barbagallo , V. Bécares , F. Bečvář , F. Belloni , E. Berthoumieux , J. Billowes , V. Boccone , M. Brugger , M. Calviani , F. Calviño , D. Cano-Ott , C. Carrapiço , F. Cerutti , E. Chiaveri , M. Chin , G. Cortés , M. A. Cortés-Giraldo , M. Diakaki , C. Domingo-Pardo , R. Dressler , I. Duran , N. Dzysiuk , C. Eleftheriadis , A. Ferrari , K. Fraval , S. Ganesan , A. R. García , G. Giubrone , M. B. Gómez-Hornillos , I. F. Gonçalves , E. González-Romero , E. Griesmayer , C. Guerrero , F. Gunsing , P. Gurusamy , S. Heinitz , D. G. Jenkins , E. Jericha , Y. Kadi , F. Käppeler , D. Karadimos , N. Kivel , P. Koehler , M. Kokkoris , M. Krtička , J. Kroll , C. Langer , C. Lederer , H. Leeb , L. S. Leong , S. Lo Meo , R. Losito , A. Manousos , J. Marganiec , T. Martìnez , C. Massimi , P. F. Mastinu , M. Mastromarco , M. Meaze , E. Mendoza , A. Mengoni , P. M. Milazzo , F. Mingrone , M. Mirea , W. Mondalaers , C. Paradela , A. Pavlik , J. Perkowski , A. Plompen , J. Praena , J. M. Quesada , T. Rauscher , R. Reifarth , A. Riego , F. Roman , C. Rubbia , R. Sarmento , A. Saxena , P. Schillebeeckx , S. Schmidt , D. Schumann , G. Tagliente , J. L. Tain , D. Tarrío , L. Tassan-Got , A. Tsinganis , S. Valenta , G. Vannini , V. Variale , P. Vaz , A. Ventura , R. Versaci , M. J. Vermeulen , V. Vlachoudis , R. Vlastou , A. Wallner , T. Ware , M. Weigand , C. Weiß , T. Wright

Purpose: To validate the accuracy of 4D Monte Carlo (4DMC) simulations to calculate dose deliveries to a deforming anatomy in the presence of realistic respiratory motion traces. A previously developed deformable lung phantom comprising an…

Medical Physics · Physics 2023-05-04 Sara Gholampourkashi , Joanna E. Cygler , Bernie Lavigne , Emily Heath

Low-dose computed tomography (LDCT) reduces radiation exposure but also introduces substantial noise and structural degradation, making it difficult to suppress noise without erasing subtle anatomical details. In this paper, we present…

Computer Vision and Pattern Recognition · Computer Science 2026-03-24 Tangtangfang Fang , Yang Jiao , Xiangjian He , Jingxi Hu , Jiaqi Yang

Four-dimensional computed tomography (4DCT) has been widely used in cancer radiotherapy for accurate target delineation and motion measurement for tumors in thorax and upper abdomen areas. However, 4DCT simulation is associated with much…

Medical Physics · Physics 2015-05-19 Zhen Tian , Xun Jia , Steve B. Jiang

General purpose computing on graphic processing units (GPU) is a potential method of speeding up scientific computation with low cost and high energy efficiency. We experimented with the particle physics simulation toolkit Geant4 used at…

Computational Physics · Physics 2012-09-25 Otto Seiskari , Jukka Kommeri , Tapio Niemi