Related papers: Scalable regression calibration approaches to corr…
Wearable devices are often used in clinical and epidemiological studies to monitor physical activity behavior and its influence on health outcomes. These devices are worn over multiple days to record activity patterns, such as step counts…
Wearable devices enable the continuous monitoring of physical activity (PA) but generate complex functional data with poorly characterized errors. Most work on functional data views the data as smooth, latent curves obtained at discrete…
While extensive work has been done to correct for biases due to measurement error in scalar-valued covariates prone to errors in generalized linear regression models, limited work has been done to address biases associated with functional…
Wearable devices collect time-varying biobehavioral data, offering opportunities to investigate how behaviors influence health outcomes. However, these data often contain measurement error and excess zeros (due to nonwear, sedentary…
In many longitudinal settings, time-varying covariates may not be measured at the same time as responses and are often prone to measurement error. Naive last-observation-carried-forward methods incur estimation biases, and existing…
Measurement error arises through a variety of mechanisms. A rich literature exists on the bias introduced by covariate measurement error and on methods of analysis to address this bias. By comparison, less attention has been given to errors…
In recent years, wearable devices have become more common to capture a wide range of health behaviors, especially for physical activity and sedentary behavior. These sensor-based measures are deemed to be objective and thus less prone to…
Several factors make clustering of functional data challenging, including the infinite-dimensional space to which observations belong and the lack of a defined probability density function for the functional random variable. To overcome…
Computer models are commonly used to represent a wide range of real systems, but they often involve some unknown parameters. Estimating the parameters by collecting physical data becomes essential in many scientific fields, ranging from…
In epidemiology, obtaining accurate individual exposure measurements can be costly and challenging. Thus, these measurements are often subject to error. Regression calibration with a validation study is widely employed as a study design and…
Wearable devices such as the ActiGraph are now commonly used in health studies to monitor or track physical activity. This trend aligns well with the growing need to accurately assess the effects of physical activity on health outcomes such…
Increased use of sensor signals from wearable devices as rich sources of physiological data has sparked growing interest in developing health monitoring systems to identify changes in an individual's health profile. Indeed, machine learning…
Two-phase sampling designs are frequently employed in epidemiological studies and large-scale health surveys. In such designs, certain variables are exclusively collected within a second-phase random subsample of the initial first-phase…
Measurement error arises commonly in clinical research settings that rely on data from electronic health records or large observational cohorts. In particular, self-reported outcomes are typical in cohort studies for chronic diseases such…
Contamination of covariates by measurement error is a classical problem in multivariate regression, where it is well known that failing to account for this contamination can result in substantial bias in the parameter estimators. The nature…
Most sensor calibrations rely on the linearity and steadiness of their response characteristics, but practical sensors are nonlinear, and their response drifts with time, restricting their choices for adoption. To broaden the realm of…
With the increasing availability of wearable devices, continuous monitoring of individuals' physiological and behavioral patterns has become significantly more accessible. Access to these continuous patterns about individuals' statuses…
In many medical studies, patients are followed longitudinally and interest is on assessing the relationship between longitudinal measurements and time to an event. Recently, various authors have proposed joint modeling approaches for…
Measurement error is an important problem that has not been very well studied in the context of Functional Data Analysis. To the best of our knowledge, there are no existing methods that address the presence of functional measurement errors…
The challenge of handling missing data is widespread in modern data analysis, particularly during the preprocessing phase and in various inferential modeling tasks. Although numerous algorithms exist for imputing missing data, the…