Related papers: Exposing a fibre-based dual-readout calorimeter to…
We present the results of a test beam campaign on a capillary-tube fibre-based dual-readout calorimeter, designed for precise hadronic and electromagnetic energy measurements in future collider experiments. The calorimeter prototype…
A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced…
In this paper, we describe measurements of the response functions of a fiber-based dual- readout calorimeter for pions, protons and multiparticle "jets" with energies in the range from 10 to 180 GeV. The calorimeter uses lead as absorber…
In this paper, we describe the first tests of a dual-readout fiber calorimeter in which silicon photomultipliers are used to sense the (scintillation and Cherenkov) light signals. The main challenge in this detector is implementing a design…
The RD52 (DREAM) collaboration is performing R\&D on dual readout calorimetry techniques with the aim of improving hadronic energy resolution for future high energy physics experiments. The simultaneous detection of Cherenkov and…
This paper discusses the ongoing development and testing of dual-readout fiber-based calorimeter demonstrators. An overview of the existing prototype will be presented, along with details on the assembly and integration strategies of the…
An iron- plastic-scintillator shashlik calorimeter with a 4.3 $X_0$ longitudinal segmentation was tested in November 2016 at the CERN East Area facility with charged particles up to 5 GeV. The performance of this detector in terms of…
We present results of the performance of the second prototype of the CASTOR quartz-tungsten sampling calorimeter, to be installed in the very forward region of the CMS experiment at the LHC. The energy linearity and resolution, as well as…
A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of…
Results are presented of beam tests in which a small electromagnetic calorimeter consisting of lead tungstate crystals was exposed to 50 GeV electrons and pions. This calorimeter was backed up by the DREAM Dual-Readout calorimeter, which…
In the context of developing a hadron calorimeter with extremely fine granularity for the application of Particle Flow Algorithms to the measurement of jet energies at a future lepton collider, we report on extensive tests of a small scale…
High resolution calorimetry with state-of-the-art energy resolution performance for both electromagnetic (EM) and hadronic signals can be achieved using the dual-readout (DR) technique, both in a homogeneous scintillating-crystal…
A Lead-Scintillating Fiber (Pb/SciFi) prototype for the Barrel Imaging Calorimeter (BIC) at the Electron--Ion Collider (EIC) was tested with electron beams at the CERN PS T10 beam line in August 2024. The prototype consisted of unit modules…
In experimental nuclear physics (NP), high-precision electromagnetic calorimetry typically requires a good energy resolution and linear photosensor response on the level of (1-2)% over a full dynamic range of the detector. The beam of…
The RD52 Project at CERN is a pure instrumentation experiment whose goal is to understand the fundamental limitations to hadronic energy resolution, and other aspects of energy measurement, in high energy calorimeters. We have found that…
In particle physics experiments, the quality of calorimetric particle detection is typically considerably worse for hadrons than for electromagnetic showers. In this paper, we investigate the root causes of this problem and evaluate two…
The performance of the CMS electromagnetic calorimeter upgraded readout electronics, developed for the High-Luminosity phase of the LHC, is discussed. Data collected in two beam test campaigns conducted in 2018 and 2021 at the H4 and H2…
The best measurement of the cosmic ray positron flux available today was performed by the HEAT balloon experiment more than 10 years ago. Given the limitations in weight and power consumption for balloon experiments, a novel approach was…
The scintillating properties of active materials used in high energy and particle physics experiments play an important role regarding the performances of both calorimeters and experiments. Two scintillator materials, a scintillating glass…
An imaging calorimeter has been designed and is being built for the PAMELA satellite-borne experiment. The physics goals of the experiment are the measurement of the flux of antiprotons, positrons and light isotopes in the cosmic radiation.…