Related papers: Calibration of a Micromegas-based Gaseous Time Pro…
This paper describes the calibration procedure for the drift tubes of the CMS barrel muon system and reports the main results obtained with data collected during a high statistics cosmic ray data-taking period. The main goal of the…
We describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to…
We report on a novel calibration method of gaseous detectors using an internal \ce{^{37}Ar} source. The \ce{^{37}Ar} is a fast-decaying and low-energy calibration source that provides a mono-energetic peak of 2.82 keV. A gaseous…
We propose to use stopping cosmic-ray muons in the energy calibration of planned and deployed large underwater detectors. The method is based on the proportionality between the incident muon energy and the length of the muon path before it…
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed…
Liquid argon time projection chambers have emerged as a competitive technology for detecting solar neutrinos. The SoLAr collaboration was formed to explore argon detectors with pixelated light and charge readout, aiming for high detection…
A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN…
We report the design, construction, and initial commissioning results of a large high pressure gaseous Time Projection Chamber (TPC) with Micromegas modules for charge readout. The detector vessel has an inner volume of about 600 L and an…
Cosmic ray muon has strong penetrating power and no ionizing radiation hazards, which makes it an ideal probe for detecting special nuclear materials. In this paper, a high spatial resolution muon tomography system based on Micromegas…
A Nd:YAG laser was used to simulate charged particle tracks at known positions in the CERES Time Projection Chamber at the CERN SPS. The system was primarily developed to study the response of the readout electronics and to calibrate the…
This paper describes a new measurement of the flux ratio of positive and negative muons from cosmic-ray interactions in the atmosphere, using data collected by the CMS detector at ground level and in the underground experimental cavern. The…
A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…
Large liquid argon time projection chambers (LArTPCs), especially those operating near the surface, are susceptible to space charge effects. In the context of LArTPCs, the space charge effect is the build-up of slow-moving positive ions in…
The LHCb Muon system performance is presented using cosmic ray events collected in 2009. These events allowed to test and optimize the detector configuration before the LHC start. The space and time alignment and the measurement of chamber…
Muons from cosmic-ray interactions in the atmosphere provide a high-statistics source of particles that can be used to study the performance and calibration of the ATLAS detector. Cosmic-ray muons can penetrate to the cavern and deposit…
The performance of muon reconstruction in CMS is evaluated using a large data sample of cosmic-ray muons recorded in 2008. Efficiencies of various high-level trigger, identification, and reconstruction algorithms have been measured for a…
A position sensitive thin gap chamber has been developed. The position resolution was measured using the cosmic muons. This paper presents the structure of this detector, position resolution measurement method and results.
A measurement is presented of the flux ratio of positive and negative muons from cosmic ray interactions in the atmosphere, using data collected by the CMS detector at ground level and in the underground experimental cavern. The excellent…
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors…
Muon-Induced X-ray Emission (MIXE) is a non-destructive analytical technique that leverages negative muons to probe elemental and isotopic compositions by detecting characteristic muonic X-rays emitted during atomic cascades and gamma rays…