Related papers: Validation of 4D Monte Carlo dose calculations usi…

200 papers

The interplay between the beam delivery time structure and the patient motion makes 4D dose calculation (4DDC) important when treating moving tumors with intensity modulated proton therapy. 4DDC based on phase sorting of a 4DCT suffers from…

Medical Physics · Physics 2023-10-13 Ivar Bengtsson , Erik Engwall , Albin Fredriksson , Lars Glimelius

Purpose: The presence of respiratory motion during radiation treatment leads to degradation of the expected dose distribution, both for target coverage and healthy-tissue sparing, particularly for techniques like pencil-beam scanning proton…

The XCAT phantom is a realistic 4D digital torso phantom that is widely used in imaging and therapy research. However, lung mass is not conserved between respiratory phases of the phantom, making detailed dosimetric simulations and dose…

Purpose: Respiratory motion and the interplay effect cause the dose delivered to a patient with spot-scanned proton therapy to differ from the dose planned for during optimization. A new 4D robust optimization methodology was developed…

The purpose of this work is to develop viable procedures for verifying the applicability of personalized dosimetry in computed tomography (CT) using Monte Carlo-based simulations. Mobile equipment together with customized software was…

Purpose: To develop a Monte Carlo (MC) therapeutic dose calculation toolkit of a recently released ring gantry linac in Geant4 (Version 10.7) for secondary dose validation of radiotherapy plan. Methods: For the Halcyon (Varian Medical…

Medical Physics · Physics 2022-10-04 Ruirui Liu , Zhen Ji , Xiandong Zhao , Tianyu Zhao , Abhishek Sethi , Daren Sawkey , Bin Cai

Monte Carlo (MC) simulation is commonly considered to be the most accurate dose calculation method in radiotherapy. However, its efficiency still requires improvement for many routine clinical applications. In this paper, we present our…

Medical Physics · Physics 2015-05-28 Xun Jia , Xuejun Gu , Yan Jiang Graves , Michael Folkerts , Steve B. Jiang

Purpose: In this study, we present the creation of an anthropomorphic, head and neck, nuclear medicine phantom and its characterization for the validation of a Monte Carlo, SPECT image based, Iodine-131 RPT dosimetry workflow. Methods: 3D…

Accurate proton dose calculation using Monte Carlo (MC) is computationally demanding in workflows like robust optimisation, adaptive replanning, and probabilistic inference, which require repeated evaluations. To address this, we develop a…

Machine Learning · Statistics 2025-09-24 Aaron Pim , Tristan Pryer

Purpose: 4D CBCT is a beneficial tool for the treatment of movable tumors, because it can help us to understand where the tumors are actually located and have a precise treatment plan. However, there is a limitation that general CBCT images…

Radiation therapy presents a need for dynamic tracking of a target tumor volume. Fiducial markers such as implanted gold seeds have been used to gate radiation delivery but the markers are invasive and gating significantly increases…

Computer Vision and Pattern Recognition · Computer Science 2019-09-27 Markus D. Foote , Blake E. Zimmerman , Amit Sawant , Sarang Joshi

Due to the increasing complexity of radiotherapy delivery, accurate dose verification has become an essential part of the clinical treatment process. The purpose of this work was to develop an electronic portal image (EPI) based…

Medical Physics · Physics 2015-06-17 Reid W Townson , Sergei Zavgorodni

Purpose: Anthropomorphic phantoms can be used in radiotherapy to confirm dose distributions. In this work, a prototype phantom with a deformable chest wall was created based on real human. Methods: A technique similar to 3-dimensional…

Medical Physics · Physics 2021-11-11 Maria Akiki , Fadi Rouphael , Mazen Moussallem

A novel dose calculation approach was designed based on the application of LSTM network that processes the 3D patient/phantom geometry as a sequence of 2D computed tomography input slices yielding a corresponding sequence of 2D slices that…

Medical Physics · Physics 2021-06-09 Ahmad Neishabouri , Niklas Wahl , Ulrich Köthe , Mark Bangert

For the one billion sufferers of respiratory disease, managing their disease with inhalers crucially influences their quality of life. Generic treatment plans could be improved with the aid of computational models that account for…

OBJECTIVE: This study evaluated the accuracy in localisation and distribution of real-time three-dimensional (4-D) ultrasound-guided biopsies on a prostate phantom. METHODS: A prostate phantom was created. A three-dimensional real-time…

Purpose: To investigate the validity of two Monte Carlo simulation absolute dosimetry approaches in the case of a small field dedicated `D'-shaped collimator used for the retinoblastoma treatment with external photon beam radiotherapy.…

Medical Physics · Physics 2018-09-25 P. A. Mayorga , L. Brualla , A. Flühs , W. Sauerwein , A. M. Lallena

When treating moving tumors, the precise delivery of proton therapy by pencil beam scanning (PBS) is challenged by the interplay effect. Although several 4D-optimization methods have been proposed, what is the most beneficial motion…

Medical Physics · Physics 2025-01-29 Ivar Bengtsson , Anders Forsgren , Albin Fredriksson

Stereotactic body radiation therapy allows for a precise and accurate dose delivery. Organ motion during treatment bears the risk of undetected high dose healthy tissue exposure. An organ very susceptible to high dose is the oesophagus. Its…

Medical Physics · Physics 2021-06-22 Tobias Fechter , Sonja Adebahr , Anca-Ligia Grosu , Dimos Baltas

Modeling of respiratory motion is important for a more accurate understanding and accounting of its effect on dose to cancers in the thorax and abdomen by radiotherapy. We have developed a model of respiration-induced organ motion in the…