English
Related papers

Related papers: tomoCAM: Fast Model-based Iterative Reconstruction…

200 papers

We propose a direct reconstruction algorithm for Computed Tomography, based on a local fusion of a few preliminary image estimates by means of a non-linear fusion rule. One such rule is based on a signal denoising technique which is…

Computer Vision and Pattern Recognition · Computer Science 2010-04-27 Joseph Shtok , Michael Zibulevsky , Michael Elad

Accurate characterization of the inner surface of X-ray monocapillary optics (XMCO) is of great significance in X-ray optics research. Compared with other characterization methods, the micro computed tomography (micro-CT) method has its…

Instrumentation and Detectors · Physics 2021-10-27 Zhao Wang , Kai Pan , Shuang Zhang , Zhuxuan Duo , Zhiguo Liu , Tianxi Sun

For reconstructing large tomographic datasets fast, filtered backprojection-type or Fourier-based algorithms are still the method of choice, as they have been for decades. These robust and computationally efficient algorithms have been…

Numerical Analysis · Mathematics 2021-08-31 Poulami Somanya Ganguly , Daniël M. Pelt , Doga Gürsoy , Francesco de Carlo , K. Joost Batenburg

Filtered backprojection (FBP) is an efficient and popular class of tomographic image reconstruction methods. In photoacoustic tomography, these algorithms are based on theoretically exact analytic inversion formulas which results in…

Image and Video Processing · Electrical Eng. & Systems 2019-08-05 Johannes Schwab , Stephan Antholzer , Markus Haltmeier

The classic imaging geometry for computed tomography is for collection of un-truncated projections and reconstruction of a global image, with the Fourier transform as the theoretical foundation that is intrinsically non-local. Recently,…

Medical Physics · Physics 2015-06-15 Ge Wang , Hengyong Yu

Recent research in computational imaging largely focuses on developing machine learning (ML) techniques for image reconstruction, which requires large-scale training datasets consisting of measurement data and ground-truth images. However,…

Image and Video Processing · Electrical Eng. & Systems 2023-09-26 Maximilian B. Kiss , Sophia B. Coban , K. Joost Batenburg , Tristan van Leeuwen , Felix Lucka

Volumetric rendering of Computed Tomography (CT) scans is crucial for visualizing complex 3D anatomical structures in medical imaging. Current high-fidelity approaches, especially neural rendering techniques, require time-consuming…

Computer Vision and Pattern Recognition · Computer Science 2025-05-26 Zhongpai Gao , Meng Zheng , Benjamin Planche , Anwesa Choudhuri , Terrence Chen , Ziyan Wu

Interrupted X-ray computed tomography (X-CT) has been the common way to observe the deformation of materials during an experiment. While this approach is effective for quasi-static experiments, it has never been possible to reconstruct a…

Instrumentation and Detectors · Physics 2024-10-29 Ivan Grega , William F. Whitney , Vikram S. Deshpande

In this work, we investigate the use of spatio-temporalImplicit Neural Representations (INRs) for dynamic X-ray computed tomography (XCT) reconstruction under interlaced acquisition schemes. The proposed approach combines ADMM-based…

Image and Video Processing · Electrical Eng. & Systems 2025-10-13 Mathias Boulanger , Ericmoore Jossou

We introduce a new CT image reconstruction algorithm that is less affected by various artifacts. The new reconstruction algorithm is a method of minimizing the difference between synchrotron X-ray tomography data and sinograms generated…

Medical Physics · Physics 2021-11-22 Byung Chun Kim , Hyunju Lee , Kyungtaek Jun

In application of tomography imaging, limited-angle problem is a quite practical and important issue. In this paper, an iterative reprojection-reconstruction (IRR) algorithm using a modified Papoulis-Gerchberg (PG) iterative scheme is…

Computer Vision and Pattern Recognition · Computer Science 2019-05-01 Yuli Sun , Jinxu Tao , Conggui Liu

Computed tomography (CT) reconstructs volumetric images using X-ray projection data acquired from multiple angles around an object. For low-dose or sparse-view CT scans, the classic image reconstruction algorithms often produce severe noise…

Medical Physics · Physics 2024-03-04 Wenxiang Cong , Wenjun Xia , Ge Wang

Purpose: Optoacoustic tomography (OAT) is inherently a three-dimensional (3D) inverse problem. However, most studies of OAT image reconstruction still employ two-dimensional (2D) imaging models. One important reason is because 3D image…

Medical Physics · Physics 2013-04-09 Kun Wang , Chao Huang , Yu-Jiun Kao , Cheng-Ying Chou , Alexander A. Oraevsky , Mark A. Anastasio

This project is aimed at designing the fast forward projection algorithm and also the backprojection algorithm for cone beam CT imaging systems with circular X-ray source trajectory. The principle of the designs is based on utilizing the…

Data Structures and Algorithms · Computer Science 2016-05-18 Junqi Tang

Cardiovascular magnetic resonance (CMR) imaging is the gold standard for diagnosing several heart diseases due to its non-invasive nature and proper contrast. MR imaging is time-consuming because of signal acquisition and image formation…

Image and Video Processing · Electrical Eng. & Systems 2025-04-29 Kian Anvari Hamedani , Narges Razizadeh , Shahabedin Nabavi , Mohsen Ebrahimi Moghaddam

Nowadays, the field computed tomography (CT) encompasses a large variety of settings, ranging from nanoscale to meter-sized objects imaged by different kinds of radiation in various acquisition modes. This experimental diversity challenges…

Numerical Analysis · Mathematics 2019-01-11 Simon Maretzke

Image-generative artificial intelligence (AI) has garnered significant attention in recent years. In particular, the diffusion model, a core component of generative AI, produces high-quality images with rich diversity. In this study, we…

Computer Vision and Pattern Recognition · Computer Science 2024-09-13 Sho Ozaki , Shizuo Kaji , Toshikazu Imae , Kanabu Nawa , Hideomi Yamashita , Keiichi Nakagawa

Cone-beam CT (CBCT) has been widely used in image guided radiation therapy (IGRT) to acquire updated volumetric anatomical information before treatment fractions for accurate patient alignment purpose. However, the excessive x-ray imaging…

Medical Physics · Physics 2010-04-13 Xun Jia , Yifei Lou , John Lewis , Ruijiang Li , Xuejun Gu , Chunhua Men , William Y. Song , Steve B. Jiang

Detector lag and gantry motion during x-ray exposure and integration both result in azimuthal blurring in CT reconstructions. These effects can degrade image quality both for high-resolution features as well as low-contrast details. In this…

Medical Physics · Physics 2018-05-31 Steven Tilley , Alejandro Sisniega , Jeffrey H. Siewerdsen , J. Webster Stayman

Scatter due to interaction of photons with the imaged object is a fundamental problem in X-ray Computed Tomography (CT). It manifests as various artifacts in the reconstruction, making its abatement or correction critical for image quality.…

Medical Physics · Physics 2024-01-30 Berk Iskender , Yoram Bresler