Related papers: Resolution Improvement for OpticalCoherence Tomogr…
Radio synthesis imaging is dependent upon deconvolution algorithms to counteract the sparse sampling of the Fourier plane. These deconvolution algorithms find an estimate of the true sky brightness from the necessarily incomplete sampled…
In Optical Coherence Tomography (OCT), speckle noise significantly hampers image quality, affecting diagnostic accuracy. Current methods, including traditional filtering and deep learning techniques, have limitations in noise reduction and…
Total variation (TV) regularization is a popular reconstruction method for ill-posed imaging problems, and particularly useful for applications with piecewise constant targets. However, using TV for medical cone-beam computed X-ray…
For a unified analysis of medical images from different modalities, data harmonization using image-to-image (I2I) translation is desired. We study this problem employing an optical coherence tomography (OCT) data set of Spectralis-OCT and…
Sparse-view Computed Tomography (CT) reconstructs images from a limited number of X-ray projections to reduce radiation and scanning time, which makes reconstruction an ill-posed inverse problem. Deep learning methods achieve high-fidelity…
Optical diffraction tomography (ODT) is a three-dimensional (3D) quantitative phase imaging technique, which enables the reconstruction of the 3D refractive index (RI) distribution of a transparent sample. Due to its fast, non-invasive, and…
Acoustic-Resolution Photoacoustic Microscopy (AR-PAM) is promising for subcutaneous vascular imaging, but its spatial resolution is constrained by the Point Spread Function (PSF). Traditional deconvolution methods like Richardson-Lucy and…
In this paper, we propose a Bayesian MAP estimator for solving the deconvolution problems when the observations are corrupted by Poisson noise. Towards this goal, a proper data fidelity term (log-likelihood) is introduced to reflect the…
Quantum-optical coherence tomography (QOCT) is an optical sectioning modality based on the quantum interference of photon pairs, obtained from a spontaneous parametric downconversion (SPDC) source. The promise of QOCT derives from two…
Current spectroscopic optical coherence tomography (OCT) methods rely on a posteriori numerical calculation. We present an alternative for accessing optically the spectroscopic information in OCT, i.e. without any post-processing, by using…
We proposed a deconvolution optical-resolution photoacoustic microscope for high -resolution imaging of brain. The focal spot of the photoacoustic microscopy is measured to obtain the lateral PSF (point spread function) of the system.…
A new algorithm for solving large-scale convex optimization problems with a separable objective function is proposed. The basic idea is to combine three techniques: Lagrangian dual decomposition, excessive gap and smoothing. The main…
Using spectrally correlated photon pairs instead of classical laser light and coincidence detection instead of light intensity detection, Quantum Optical Coherence Tomography (Q-OCT) outperforms classical OCT in several experimental terms.…
We present a variational Bayesian method of joint image reconstruction and point spread function (PSF) estimation when the PSF of the imaging device is only partially known. To solve this semi-blind deconvolution problem, prior…
Dispersion is a common phenomenon in optics due to the frequency dependence of the refractive index in polychromatic light. This issue, if left untreated in optical coherence tomography (OCT) imaging, leads to signal broadening of the…
Processing of Diffusion MRI data obtained from High Angular Resolution measurements consists of a series of steps, starting with the estimation of an orientation distribution function (ODF), which is then used as input for e.g. tractography…
The problem of reconstruction of digital images from their degraded measurements is regarded as a problem of central importance in various fields of engineering and imaging sciences. In such cases, the degradation is typically caused by the…
Deconvolution is the most widely used aberration correction technique in microscopy, however most techniques assume that the aberrations are the same for each point in the image, which is rarely true. Methods for tracking spatially varying…
Image Phase Alignment Super-sampling (ImPASS) is a computational method for combining displaced low-resolution images into a single high-resolution image. The general steps include measuring the relative displacements, up-sampling, aligning…
Optical coherence tomography (OCT) enables high-resolution and non-invasive 3D imaging of the human retina but is inherently impaired by speckle noise. This paper introduces a spatio-temporal denoising algorithm for OCT data on a B-scan…