Related papers: mcLARO: Multi-Contrast Learned Acquisition and Rec…
Multiple-input multiple-output (MIMO) radar is one of the leading depth sensing modalities. However, the usage of multiple receive channels lead to relative high costs and prevent the penetration of MIMOs in many areas such as the…
Magnetic Resonance Imaging (MRI) has long been considered to be among "the gold standards" of diagnostic medical imaging. The long acquisition times, however, render MRI prone to motion artifacts, let alone their adverse contribution to the…
In clinical imaging, magnetic resonance (MR) image volumes are often acquired as stacks of 2D slices with decreased scan times, improved signal-to-noise ratio, and image contrasts unique to 2D MR pulse sequences. While this is sufficient…
Purpose: To implement and evaluate a sequential approach to obtain semi-quantitative T1-weighted MPRAGE images, unbiased by B1 inhomogeneities at 7T. Methods: In the reference gradient echo used for normalization of the MPRAGE image, flip…
22. Shortening acquisition time and reducing the motion-artifact are two of the most critical issues in MRI. As a promising solution, high-quality MRI image restoration provides a new approach to achieve higher resolution without costing…
Magnetic resonance imaging (MRI) nowadays serves as an important modality for diagnostic and therapeutic guidance in clinics. However, the {\it slow acquisition} process, the dynamic deformation of organs, as well as the need for {\it…
Purpose: T2* quantification from gradient echo magnetic resonance imaging is particularly affected by subject motion due to the high sensitivity to magnetic field inhomogeneities, which are influenced by motion and might cause signal loss.…
We propose a k-space preconditioning formulation for accelerating the convergence of iterative Magnetic Resonance Imaging (MRI) reconstructions from non-uniformly sampled k-space data. Existing methods either use sampling density…
Purpose: This study aims to improve 0.55T T2-weighted PROPELLER lung MRI through a self-supervised joint reconstruction and denoising model. Methods: T2-weighted 0.55T lung MRI dataset including 44 patients with previous covid infection…
Magnetic resonance (MR) images from multiple sources often show differences in image contrast related to acquisition settings or the used scanner type. For long-term studies, longitudinal comparability is essential but can be impaired by…
Acquiring images in high resolution is often a challenging task. Especially in the medical sector, image quality has to be balanced with acquisition time and patient comfort. To strike a compromise between scan time and quality for Magnetic…
Purpose: To improve upon Extreme MRI, a recently proposed method by Ong Et al. for reconstructing high spatiotemporal resolution, 3D non-Cartesian acquisitions by incorporating motion compensation into these reconstructions using an…
Magnetic Resonance Imaging (MRI) is an important medical imaging modality, while it requires a long acquisition time. To reduce the acquisition time, various methods have been proposed. However, these methods failed to reconstruct images…
Purpose: To develop an accelerated Cartesian MRF implementation using a multi-shot EPI sequence for rapid simultaneous quantification of T1 and T2 parameters. Methods: The proposed Cartesian MRF method involved the acquisition of highly…
We introduce a novel optimization algorithm for image recovery under learned sparse and low-rank constraints, which we parameterize as weighted extensions of the $\ell_p^p$-vector and $\mathcal S_p^p$ Schatten-matrix quasi-norms for…
We developed a deep learning-based model observer (DLMO) to evaluate a multi-coil sensitivity encoding parallel MRI system at different accelerations on the Rayleigh discrimination task as a surrogate measure of resolution. We inserted…
Efficient and accurate low-rank approximations of multiple data sources are essential in the era of big data. The scaling of kernel-based learning algorithms to large datasets is limited by the O(n^2) computation and storage complexity of…
Multi-contrast images are commonly acquired together to maximize complementary diagnostic information, albeit at the expense of longer scan times. A time-efficient strategy to acquire high-quality multi-contrast images is to accelerate…
Cine cardiac magnetic resonance (CMR) imaging is considered the gold standard for cardiac function evaluation. However, cine CMR acquisition is inherently slow and in recent decades considerable effort has been put into accelerating scan…
The advancement of sensing technology has driven the widespread application of high-dimensional data. However, issues such as missing entries during acquisition and transmission negatively impact the accuracy of subsequent tasks. Tensor…